| Marque | ROCKWILL |
| Série | JDS |
Product Overview
As a pioneer and the first dedicated original equipment manufacturer (OEM) in China's neutral grounding transformer industry, we have laid the original benchmark for the industry's development with our profound technical strength accumulated through decades of intensive cultivation. From the independent R&D of core technologies to large-scale mass production, we have built a full-process independently controllable system. Relying on our stable and leading product performance and unparalleled reliability, we have become a preferred partner in the field of power grid construction.
Rockwill delivers reliable and high-performance earthing transformers designed for 66kV power systems. Our oil-immersed transformers are engineered to provide stable neutral grounding solutions while ensuring operational safety and system protection. Manufactured in compliance with international standards including IEC and GB, these transformers incorporate premium materials and rigorous quality control throughout production.
Basic Info.
Some of these earthing transformers cover voltage levels including:3.3kV / 6kV / 11kV / 15kV / 20kV / 22kV / 30kV / 33kV / 34.5kV / 36kV / 44kV / 66kV / 88kV / 110kV / 132kV / 145kV / 150kV / 220kV / 275kV / 330kV / 400kV, etc. The current withstand time ranges from 1s, 2s, 3s, 5s, 6s, 8s, 9s, 10s, 30s, 60s, 1hour to 2hours, and customization is available.
Parameter |
Detail |
Parameter |
Details |
Cooling Method |
Oil-Immersed Type Transformer |
Core |
Core-type Transformer |
Certification |
ISO9001 |
Usage |
Power Transformer |
Frequency Characteristics |
Power Frequency |
Shape of Core |
Ring |
Brand |
Rockwill |
Item |
3 Phase Oil Type Earthing 6kv Power Transformer |
Primary Voltage |
66kv |
Secondary Voltage |
0.4kv |
Rating Capacity |
350kVA |
Transformer |
66kv Power Transformer |
Iron Core |
Wounded Core |
Coil Structure |
Isolation |
Loss |
Low Losses |
Tank Design |
Sealed |
Specification |
CTQC type tested |
Transport Package |
Wooden Case |
Origin |
Zhejiang China |
Trademark |
Rockwill |
Key Features
Voltage Class: 66kV system voltage (200 BIL)
Capacity Range: Standard units from 100kVA to 10,000kVA
Winding Configuration: Optimized zigzag (ZNyn) design
Cooling System: ONAN/OFAF cooling options
Insulation: Mineral oil or synthetic ester fluid
Construction:
Corrugated tank or radiator cooling
Hermetically sealed or conservator tank options
CRGO silicon steel core
Copper/aluminum windings
Technical Advantages
Enhanced Safety: Built-in Buchholz relay and pressure relief device
Low Impedance: Zero-sequence impedance <15Ω for effective fault current management
Durability: Corrosion-resistant paint system for outdoor installations
Efficiency: Reduced no-load losses through optimized core design
Flexibility: Off-circuit tap changer (±5% in 2.5% Steps)
Typical Applications
Utility Networks:
Neutral grounding for 66kV transmission systems
Arc suppression coil connections
Resistance grounding systems
Industrial Plants:
Petrochemical facilities
Mining operations
Steel manufacturing plants
Renewable Energy:
Wind farm collector stations
Solar PV substations
Hydroelectric plants
Performance Specifications
Temperature Range: -30°C to +40°C Ambient
Humidity: ≤95% Monthly Average
Altitude: Up to 2000m ASL
Sound Level: ≤75dB at 1m
Efficiency: ≥99.2% at Full Load
Testing Protocol
All units undergo comprehensive testing including:
Zero sequence impedance measurement
Induced overvoltage test (260Hz)
Lightning impulse test (350kV)
Temperature rise test (65K max.)
Oil dielectric strength test (≥50kV)
Service Conditions
Suitable for indoor/outdoor installation
Wind resistant up to 35m/s
Non-explosive environments
Seismic capability: 0.3g horizontal acceleration
Application Fields
66kV/88kV/110kV/132kV Power Distribution Network Construction
New Energy Power Plants (e.g., Wind Power/Photovoltaic)
Power Distribution Stations in Large Industrial Parks
Railway Traction Power Supply Systems
Urban Power Grid Upgrading and Renovation Projects
High-Voltage Power Supply Systems for Industrial and Mining Enterprises
Grounding Protection Projects of Regional Substations
Un transformateur de terre est un type spécial de transformateur qui crée artificiellement un point neutre pour les systèmes électriques non mis à la terre ou mis à la terre avec un courant faible. Il construit un circuit de mise à la terre par le biais d'un enroulement spécifique, avec deux fonctions principales : premièrement, il fournit un chemin de faible impédance pour le courant de séquence zéro dans le système, garantissant que le courant de défaut atteigne le seuil de fonctionnement du dispositif de protection relais lorsqu'une panne de phase unique se produit, permettant ainsi une localisation et une isolation rapides de la panne ; deuxièmement, il maintient l'équilibre de la tension du système, supprime l'augmentation excessive de la tension des phases non défectueuses pendant les pannes, et protège la sécurité de l'isolation des équipements du réseau électrique. Contrairement aux transformateurs de puissance ordinaires, sa fonction principale est de "construire un circuit de mise à la terre" plutôt que de "transformer la tension", et il est généralement conçu selon une capacité de charge à court terme plutôt qu'une capacité de fonctionnement continue.
Les différences entre les deux proviennent de la différence essentielle dans le positionnement fonctionnel, se reflétant spécifiquement dans trois aspects : ① Fonctions centrales différentes : les transformateurs électriques ordinaires se concentrent sur la transformation de tension et la transmission d'énergie, tandis que les transformateurs de terre se concentrent sur la construction de points neutres et la fourniture de chemins de courant de défaut ; ② Calibrage de capacité différent : les transformateurs électriques ordinaires sont marqués avec une capacité de fonctionnement continu (capacité de charge à long terme), tandis que les transformateurs de terre sont marqués avec une capacité nominale à court terme (capacité qui peut être supportée dans un temps spécifié en fonction du courant de défaut et du temps de résistance, par exemple 30 secondes) ; ③ Conceptions de bobinages différentes : les transformateurs de terre adoptent principalement des structures de bobinage spéciales comme le zigzag (ZN), tandis que les transformateurs électriques ordinaires utilisent principalement des bobinages conventionnels tels que l'étoile et le triangle, et les transformateurs de terre n'ont généralement pas de ratio de transformation de tension traditionnel.