Search


Transformateur de terre trempé dans l'huile triphasé 20kV

  • 20kV 44kV 145kV 150kV Three Phase Oil-Immersed Neutral Earthing Transformer Custom Factory

Attributs clés

Marque ROCKWILL
Série JDS
Description

Product Overview

As a pioneer and the first professional original manufacturer in China's earthing transformer industry, decades of dedicated focus have enabled us to accumulate strong technical strength and even establish the fundamental standards for industry development. Covering the entire chain from breakthroughs in core technological innovation to large-scale production and delivery, we have built an independent ecological system. With leading and stable product performance as well as extremely reliable quality, we have become a trusted choice in the field of power grid construction.

This series of three-phase oil-immersed neutral earthing transformers is a customized core equipment specifically designed for medium- and high-voltage power systems, covering voltage classes from 20kV to 150kV and adopting a fully sealed oil-immersed structure. Through factory-customized production, the product can be flexibly configured according to the user's grid parameters, installation environment, and protection requirements, providing a reliable artificial neutral point solution for ungrounded or low-current grounded systems. It effectively suppresses arc grounding overvoltage and enhances grid operational stability and safety.

Basic Info

Some of these earthing transformers cover voltage levels including:3.3kV / 6kV / 11kV / 15kV / 20kV / 22kV / 30kV / 33kV / 34.5kV / 36kV / 44kV / 66kV / 88kV / 110kV / 132kV / 145kV / 150kV / 220kV / 275kV / 330kV / 400kV, etc. The current withstand time ranges from 1s, 2s, 3s, 5s, 6s, 8s, 9s, 10s, 30s, 60s, 1hour to 2hours, and customization is available.

Model NO.

JDS

Core

Core-type Transformer

Cooling Method

Oil-immersed Type Transformer

Winding Type

Two-winding Transformer

Certification

ISO9001

Usage

Power Transformer

Frequency Characteristics

Power Frequency

Shape of Core

Ring

Brand

Rockwill

Transformer

Earthing Transformer

Rated Capacity

100 kVA

Color

Grey or Customized

Coil Material

Copper

Losses

Low Losses

Transformer Phase

3 Phase

Iron Core

Power Transformer Core

Transport Package

Wooden Case

Specification

CTQC type tested

Trademark

Rockwill

Origin

Zhejiang, China

HS Code

85042100

Production Capacity

5000MAV/Year

Key Specifications

  • Model: JDS-100/20

  • Capacity: 100kVA

  • Voltage: 20kV

  • Frequency: 50/60Hz

  • Winding: Copper two-winding design

  • Core: Ring-shaped silicon steel

  • Cooling: ONAN (Oil Natural Air Natural)

  • Impedance: Low zero-sequence impedance (<10&Omega;)

  • Certification: ISO 9001, CTQC tested

Technical Advantages

     Superior Grounding Performance

    • Specially designed winding configuration for optimal neutral point stability

    • Withstands 100A short-circuit current for 10 seconds

    • Low zero-sequence impedance ensures effective fault current diversion

    Advanced Oil-Cooled Design

    • Hermetically sealed corrugated tank prevents oil contamination

    • Mineral oil insulation with -30&deg;C to +40&deg;C operating range

    • Optional Midel 7131 ester fluid for enhanced fire safety

    Robust Construction

    • Heavy-gauge steel tank with anti-corrosion treatment

    • Precision-engineered core with reduced magnetic losses

    • Vibration-resistant mounting system

    Smart Protection Features

    • Standard Buchholz relay for internal fault detection

    • Pressure relief device for overload conditions

    • Oil level indicator with alarm contacts

Application Scenarios

Industrial Power Systems

    • Ideal for manufacturing plants with sensitive equipment

    • Protects against ground faults in 20kV distribution networks

    • Suitable for harsh industrial environments

    Renewable Energy Installations

    • Wind farm collector substations

    • Solar park step-up stations

    • Biomass power generation facilities

    Infrastructure Projects

    • Metro power supply systems

    • Airport electrical networks

    • Hospital backup power systems

Why Choose Rockwill?

  • 20+ years of transformer manufacturing expertise

  • Custom engineering support available

  • Complete type test reports provided

  • Global service network with 24/7 technical support

  • Environmentally conscious production processes

Solutions - Earthing Transformer

  • Services de maintenance intelligents et solutions durables pour les transformateurs de terre de type Z
    Services de maintenance intelligents et solutions durables pour les transformateurs de terre de type ZLes transformateurs de terre de type Z sont essentiels pour stabiliser les systèmes électriques non mis à la terre ou en triangle, en fournissant un chemin d'impédance faible pour les courants de séquence nulle en cas de défaut. L'intégration de pratiques de maintenance intelligentes et durables améliore leur fiabilité tout en minimisant l'impact environnemental. Voici une analyse structurée des

Bibliothèque de ressources documentaires Earthing Transformer

Public.
Rockwill Electric Group Profile Rockwill Electric Group Profile
Brochure
English

Questions fréquentes

<meta />

Actuellement, les standards mondiaux dominants sont divisés entre le système IEEE et le système IEC. Les normes nationales se réfèrent principalement à l'IEC et sont adaptées selon les conditions nationales. Les normes clés et leurs points de focalisation respectifs sont les suivants :
  • IEEE 32 : La norme dominante en Amérique du Nord, se concentrant sur la "performance en cas de défaut" des transformateurs de terre/masse. Elle détaille les exigences essentielles telles que les méthodes d'essai de l'impédance séquentielle zéro, le calcul du courant admissible court-circuit, et la vérification de la résistance mécanique, et constitue une base clé pour la sélection des systèmes haute et très haute tension.
  • Série IEC 60076 : La norme internationale générale clé. Parmi elles, l'IEC 60076-8 réglemente spécifiquement la conception des enroulements, les exigences d'impédance et les méthodes d'essai des transformateurs de terre/masse ; l'IEC 60076-1 définit les exigences générales pour les médias d'isolation ; l'IEC 60076-2 spécifie la classification et les indicateurs de performance des méthodes de refroidissement ; l'IEC 60076-5 spécifie les spécifications d'essai pour la capacité de tenue courte, formant ainsi un système technique complet.
  • ANSI C57.12/IEC 60038 : L'ANSI C57.12 complète les exigences de processus de fabrication des transformateurs de terre/masse en Amérique du Nord ; l'IEC 60038 unifie les valeurs nominales des niveaux de tension pour assurer la compatibilité des produits provenant de différents pays.
  • Normes nationales pertinentes : Telles que la GB/T 6451, qui se réfère à la série IEC 60076 et propose des exigences supplémentaires concernant l'efficacité, la montée en température et la résistance harmonique, en fonction des caractéristiques du réseau électrique chinois.

Connaître votre fournisseur

Boutique en ligne
Taux de livraison à temps
Temps de réponse
100.0%
≤4h
Présentation de l'entreprise
Espace de travail: 108000m² Nombre total d'employés: 700+ Exportation Annuelle Maximale (USD): 150000000
Services
Type de business: Conception/Fabrication/Ventes
Catégories principales: transformateur de courant/Postes de transformation préfabriqués et salles électriques préfabriquées/Isolation contre la foudre et protection contre la foudre/appareils électriques à haute tension/Panneaux électriques et dispositifs de commande/transformateur
Demande
+86
Cliquer pour téléverser un fichier
Télécharger
Obtenir l'application commerciale IEE-Business
Utilisez l'application IEE-Business pour trouver du matériel obtenir des solutions se connecter avec des experts et participer à la collaboration sectorielle en tout lieu et à tout moment soutenant pleinement le développement de vos projets et activités dans le secteur de l'énergie
Connexion
ou continuer avec
Nouvel utilisateur ?
S’inscrire