Transformador de tierra de aceite sumergido trifásico de 20kV

  • 20kV 44kV 145kV 150kV Three Phase Oil-Immersed Neutral Earthing Transformer Custom Factory

Atributos clave

Marca ROCKWILL
Serie JDS
Descripción

Product Overview

As a pioneer and the first professional original manufacturer in China's earthing transformer industry, decades of dedicated focus have enabled us to accumulate strong technical strength and even establish the fundamental standards for industry development. Covering the entire chain from breakthroughs in core technological innovation to large-scale production and delivery, we have built an independent ecological system. With leading and stable product performance as well as extremely reliable quality, we have become a trusted choice in the field of power grid construction.

This series of three-phase oil-immersed neutral earthing transformers is a customized core equipment specifically designed for medium- and high-voltage power systems, covering voltage classes from 20kV to 150kV and adopting a fully sealed oil-immersed structure. Through factory-customized production, the product can be flexibly configured according to the user's grid parameters, installation environment, and protection requirements, providing a reliable artificial neutral point solution for ungrounded or low-current grounded systems. It effectively suppresses arc grounding overvoltage and enhances grid operational stability and safety.

Basic Info

Some of these earthing transformers cover voltage levels including:3.3kV / 6kV / 11kV / 15kV / 20kV / 22kV / 30kV / 33kV / 34.5kV / 36kV / 44kV / 66kV / 88kV / 110kV / 132kV / 145kV / 150kV / 220kV / 275kV / 330kV / 400kV, etc. The current withstand time ranges from 1s, 2s, 3s, 5s, 6s, 8s, 9s, 10s, 30s, 60s, 1hour to 2hours, and customization is available.

Model NO.

JDS

Core

Core-type Transformer

Cooling Method

Oil-immersed Type Transformer

Winding Type

Two-winding Transformer

Certification

ISO9001

Usage

Power Transformer

Frequency Characteristics

Power Frequency

Shape of Core

Ring

Brand

Rockwill

Transformer

Earthing Transformer

Rated Capacity

100 kVA

Color

Grey or Customized

Coil Material

Copper

Losses

Low Losses

Transformer Phase

3 Phase

Iron Core

Power Transformer Core

Transport Package

Wooden Case

Specification

CTQC type tested

Trademark

Rockwill

Origin

Zhejiang, China

HS Code

85042100

Production Capacity

5000MAV/Year

Key Specifications

  • Model: JDS-100/20

  • Capacity: 100kVA

  • Voltage: 20kV

  • Frequency: 50/60Hz

  • Winding: Copper two-winding design

  • Core: Ring-shaped silicon steel

  • Cooling: ONAN (Oil Natural Air Natural)

  • Impedance: Low zero-sequence impedance (<10&Omega;)

  • Certification: ISO 9001, CTQC tested

Technical Advantages

     Superior Grounding Performance

    • Specially designed winding configuration for optimal neutral point stability

    • Withstands 100A short-circuit current for 10 seconds

    • Low zero-sequence impedance ensures effective fault current diversion

    Advanced Oil-Cooled Design

    • Hermetically sealed corrugated tank prevents oil contamination

    • Mineral oil insulation with -30&deg;C to +40&deg;C operating range

    • Optional Midel 7131 ester fluid for enhanced fire safety

    Robust Construction

    • Heavy-gauge steel tank with anti-corrosion treatment

    • Precision-engineered core with reduced magnetic losses

    • Vibration-resistant mounting system

    Smart Protection Features

    • Standard Buchholz relay for internal fault detection

    • Pressure relief device for overload conditions

    • Oil level indicator with alarm contacts

Application Scenarios

Industrial Power Systems

    • Ideal for manufacturing plants with sensitive equipment

    • Protects against ground faults in 20kV distribution networks

    • Suitable for harsh industrial environments

    Renewable Energy Installations

    • Wind farm collector substations

    • Solar park step-up stations

    • Biomass power generation facilities

    Infrastructure Projects

    • Metro power supply systems

    • Airport electrical networks

    • Hospital backup power systems

Why Choose Rockwill?

  • 20+ years of transformer manufacturing expertise

  • Custom engineering support available

  • Complete type test reports provided

  • Global service network with 24/7 technical support

  • Environmentally conscious production processes

Soluciones - Earthing Transformer

  • Servicios de Mantenimiento Inteligente y Soluciones Sostenibles para Transformadores de Aterramiento Tipo Z
    Servicios de Mantenimiento Inteligente y Soluciones Sostenibles para Transformadores de Tierra de Tipo ZLos transformadores de tierra de tipo Z son cruciales para estabilizar sistemas de energía no aterrizados o conectados en delta, proporcionando una ruta de baja impedancia para las corrientes de secuencia cero durante las fallas. La integración de prácticas de mantenimiento inteligente y sostenibilidad mejora su confiabilidad mientras minimiza el impacto ambiental. A continuación, se presenta

Biblioteca de Recursos Documentales Earthing Transformer

Public.
Rockwill Electric Group Profile Rockwill Electric Group Profile
Brochure
English

Preguntas frecuentes

<meta />

Actualmente, los estándares globales principales se dividen en el sistema IEEE y el sistema IEC. Los estándares nacionales se basan principalmente en el IEC y se adaptan según las condiciones nacionales. Los estándares centrales y sus respectivos enfoques son los siguientes:
  • IEEE 32: El estándar dominante en Norteamérica, que se centra en el "rendimiento de falla" de los transformadores de tierra/grounding. Detalla los requisitos fundamentales como los métodos de prueba de impedancia de secuencia cero, el cálculo de la corriente soportable a corto plazo y la verificación de resistencia mecánica, y es una base clave para la selección de sistemas de alta y ultra-alta tensión.
  • IEC 60076 series: El estándar internacional general central. Entre ellos, la IEC 60076-8 regula específicamente el diseño de bobinados, los requisitos de impedancia y los métodos de prueba de los transformadores de tierra/grounding; la IEC 60076-1 define los requisitos generales para los medios de aislamiento; la IEC 60076-2 especifica la clasificación e indicadores de rendimiento de los métodos de enfriamiento; la IEC 60076-5 especifica las especificaciones de prueba para la capacidad de soporte a corto plazo, formando un sistema técnico completo.
  • ANSI C57.12/IEC 60038: ANSI C57.12 complementa los requisitos de proceso de fabricación de los transformadores de tierra/grounding en Norteamérica; la IEC 60038 unifica los valores nominales de los niveles de tensión para garantizar la compatibilidad de los productos de diferentes países.
  • Estándares nacionales relevantes: Como GB/T 6451, que se basa en la serie IEC 60076 y propone requisitos suplementarios sobre eficiencia, elevación de temperatura y resistencia a armónicos de acuerdo con las características de la red eléctrica de China.

Conozca a su proveedor

Tienda en línea
Tasa de entrega puntual
Tiempo de respuesta
100.0%
≤4h
Visión general de la empresa
Lugar de trabajo: 108000m² Total de empleados: 700+ Máxima Exportación Anual (USD): 150000000
Servicios
Tipo de Negocio: Diseño/Fabricación/Ventas
Categorías principales: transformador de instrumento/Subestaciones completas y salas eléctricas prefabricadas/Aislamiento contra rayos y protección contra descargas atmosféricas/aparatos de alta tensión/Paneles eléctricos y dispositivos de control/transformador
Enviar consulta
+86
Haga clic para cargar archivo
Descargar
Obtener la aplicación IEE Business
Utiliza la aplicación IEE-Business para encontrar equipos obtener soluciones conectarte con expertos y participar en colaboraciones de la industria en cualquier momento y lugar apoyando completamente el desarrollo de tus proyectos y negocios de energía