RCW MV Triple-single recloser Brochure
Brochure · ROCKWILL

RCW MV Triple-single recloser Brochure

Overhead medium voltage distribution feeders, rural power grids, industrial distribution networks, smart distribution automation, distributed energy and renewable energy overhead lines.

Updated2026.09
LanguageEnglish
FilePDF · 312.7 KB
Triple-single recloser
Download

Document description

This document is the product flyer of RCW MV Triple‑single Recloser. It presents core specifications including 15‑38kV rated voltage, 400‑1250A rated current, with 30,000 overhaul‑free mechanical operations. Equipped with modular operating mechanism and standardized accessories for easy installation. Customized manufacturing is available, providing integrated solutions of design, assembly and testing for all primary power distribution applications.

ROCKWILL RCW MV Triple-single Vacuum Recloser is pole-mounted outdoor medium voltage auto recloser with three independent single-phase vacuum poles. It covers rated voltage 15kV, 27kV, 38kV, rated current 630A~1250A and short-circuit breaking capacity from 12.5kA up to 25kA. Designed with independent phase tripping and reclosing function, it only isolates the faulty phase during single-phase earth faults to maintain power supply on healthy phases. Fully compliant with IEC 62271-111, ANSI/IEEE C37.60 and IEC 62271-1. Equipped with intelligent controller supporting fault recording, configurable IEC/ANSI protection curves and multiple communication interfaces for overhead distribution automation and smart grid applications.

Related Products

Frequently asked questions

The Rockwill standard smart recloser offers high precision with a wide measuring range (2A–16,000A). Simply ensure your normal current is within this standard range when making a selection.

Yes. In addition to the standard 2A–16,000A range, Rockwill provides custom-configured units for ultra-low current measurement and protection in the 0.1A–2A range.

Mainly IEC 62271-111, ANSI/IEEE C37.60 and IEC 62271-1.

It supports independent phase trip. Single-phase fault will not cut off all three phases, reduce outage scope.

It is pole-mounted, widely applied on overhead MV distribution lines and smart grid distribution automation projects.