High-performance 27kV Automatic Circuit Recloser (ACR) Flyer
Brochure · ROCKWILL

High-performance 27kV Automatic Circuit Recloser (ACR) Flyer

27‑38kV heavy‑duty pole‑mounted automatic circuit recloser, three‑phase simultaneous breaking, high breaking‑capacity, multi‑protocol remote communication, for outdoor overhead smart distribution & new‑energy grid.

Add us on Google
Updated2026.09
LanguageEnglish
FilePDF · 162.6 KB
Automatic Circuit Recloserpole‑mounted recloserhigh‑voltage vacuum recloser
Download

Document description

This OEM product flyer is compiled in accordance with prevailing IEC international standards for high‑voltage switchgear and controlgear. This promotional document presents product positioning, core distinctive features and condensed technical‑parameter table.

It adopts heavy‑duty pole‑mounted mechanical‑structure design, supports three‑phase simultaneous fault breaking, intelligent remote automation interface and flexible customization for multiple installation accessories.

This flyer serves as preliminary reference for overhead distribution‑network project marketing review, pre‑selection, tender screening and project solution evaluation. Please contact us for full technical specification, dimension drawings, type‑test certificates and complete customized‑solution support.

Related Products

Frequently asked questions

The Rockwill standard smart recloser offers high precision with a wide measuring range (2A–16,000A). Simply ensure your normal current is within this standard range when making a selection.

Yes. In addition to the standard 2A–16,000A range, Rockwill provides custom-configured units for ultra-low current measurement and protection in the 0.1A–2A range.

Heavy‑duty pole‑mounted design, three‑phase simultaneous breaking for accurate fault isolation; supports multi‑protocol intelligent communication to realize remote distribution automation, suitable for smart and new‑energy distribution networks.

Line charging breaking current 5 A; cable charging breaking current 25 A, meeting the switching requirements of overhead‑line and cable‑mixed distribution networks.