RHD-Ölü Tank SF6 Gazlı Devre Kesici

  • Customization 24 kV/25.8 kV/27 kV/145kV/138kV/230kV or Other Dead tank SF6 Gas Circuit-Breaker
  • Customization 24 kV/25.8 kV/27 kV/145kV/138kV/230kV or Other Dead tank SF6 Gas Circuit-Breaker

Ana Özellikler

Marka ROCKWILL
Seri RHD
Açıklama

Product Overview

The RHD Series Dead-Tank SF6 Circuit Breaker is engineered for 'customized high-voltage power system solutions', covering standard voltage grades from RHD-40.5 to RHD-550 and supporting 'non-standard voltage customization' to precisely match your unique grid upgrade or construction needs. As a dead-tank type, its grounded tank isolates high-voltage components, ensuring superior insulation performance and safety--making it the go-to choose for demanding high-voltage scenarios.

About customization

We offer full customization services for voltage classes, including single-phase, two-phase, and three-phase configurations, as well as non-standard voltage/current solutions. Examples of available voltage and current specifications include 1250 A 75 kV, 3200 A 46 kV, 60 kV, 69 kV, and 75 kV (we support customization ranging from 10 kV to 800 kV for voltage and 1250 A to 6300 A for current). Regardless of your power grid's voltage specifications, we tailor the circuit breaker for seamless integration.

All products are fully assembled and tested at our factory before being shipped directly to your site--no disassembly of key components is required. This eliminates the need for on-site high-voltage testing, significantly saving you time and costs.

Key features

 1. Superior Seismic Resistance

Adopting a low-center-of-gravity design, the breaker can withstand an earthquake intensity of up to 9 degrees, ensuring stable performance in seismic-prone areas--consistent with the RHD series' proven anti-seismic capability.

2. Excellent Arc-Extinguishing Performance & Long Service Life

Leveraging the high arc-extinguishing efficiency of SF6 gas, the breaker achieves a rated short-circuit breaking current of ≥50kA. It boasts an electrical life of more than 20 operations and a mechanical life of up to 10,000 cycles, significantly reducing equipment replacement and maintenance costs.

3. Low SF6 Gas Leakage Rate

The hermetic metal tank structure minimizes SF6 gas leakage, with an annual leakage rate of ≤1%--far below industry averages. This design not only avoids safety hazards from gas leakage but also reduces environmental impact. 

4. Modular Design & Flexible Expansion

It supports on-demand configuration of built-in current transformers (CTs), with up to 15 CTs available for measurement or protection purposes. The standardized module interface allows flexible combination to meet diverse substation design and layout requirements, especially suitable for space-constrained scenarios.

5. Strong Environmental Adaptability

The breaker operates stably in extreme conditions: ambient temperature ranging from -40℃ to +55℃, maximum daily temperature difference of 32K, altitude up to 3,000m, and air pollution level up to Class IV. It also resists wind pressure of 700Pa (equivalent to 34m/s wind speed) and icing thickness of up to 20mm.

6. Comprehensive Safety Protection

Equipped with anti-mis operation interlocking devices, it effectively prevents accidents caused by incorrect operations. Before delivery, the breaker undergoes lightning impulse tests to eliminate insulation discharge risks from production and assembly, ensuring reliable quality.

7. Maintenance-Free Operating Mechanism

It adopts a spring-operated mechanism that is oil-free, gas-free, and maintenance-free. This mechanism delivers stable performance, low noise, and high reliability, reducing long-term operational workload.

Technology Parameters

Item Unit Parameters
customization of Rated Voltage kV

3.6 kV/4.76 kV/7.2 kV/8.25 kV/12 kV /13.2 kV/11kV/12kV/13.8kV/15kV/15.5 kV /17.5 kV/22kV/22.9 kV/24 kV/25.8 kV/27 kV/33kV/36 kV/38 kV/40.5 kV/44kV/60kV/63kV/66kV/69kV/88kV/115kV/123kV/125kV/126kV/132kV/138kV/145kV/

150kV/170kV/184kV/204kV/220kV/225kV/230kV/245kV/275kV/330kV/345kV/400kV/765kV/800kV

customization of Rated  current A 1250 to 6300
Rated frequency Hz 50/60
1min Power frequency withstand voltage kV Max to 750
Lightning impulse withstand voltage kV Max to 1675
First open pole factor   1.5/1.3/1.55
Rated short circuit breaking current kA 16 to 63
Rated short - circuit duration s 4,3
Rated out - of - phase breaking current   10
Rated cable charging current   10/50/125
Rated peak value withstand current kA 80/100/125
Rated making current (peak) kA 80/100/125
Creepage distance mm/kV 25 - 31
SF6 gas leakage rate (per year)   ≤1%
Rated SF6 gas pressure(20℃ gauge pressure) Mpa 0.5/0.4,0.5,0.6
Alarm/blocking pressure(20℃ gauge pressure) Mpa 0.45/0.4,0.35/0.33,0.45/0.40,0.55/0.50
SF6 annual gas leakage rate   ≤0.5
Gas moisture content Ppm(v) ≤150
Heater voltage   AC220/DC220
Voltage of control circuit DC DC110/DC220/DC230
Voltage of energy - store motor V DC 220/DC 110/AC 220/DC230
Applied standards   GB/T 1984/IEC 62271 - 100

 

Name unit Parameters
Opening time ms 27±3
Closing time ms 90±9
Minute and conjunction time ms 300
Together--ivide the time ms ≤60
Simultaneity of opening ms ≤3
Closing simultaneity ms ≤5
Moving contact stroke mm 150+2-4
Contact contact stroke mm 27±4
Opening speed m/s 4.5±0.5
Closing speed m/s 2.5±0.4
Mechanical life times 6000
Operation sequence   O - 0.3s - CO - 180s - CO
Note: The opening and closing speed and time are the characteristic values of the circuitbreaker when it is single divided and closed under rated conditions. The closing speed is theaverage speed of the moving contact from the rigid closing point to 10 ms before closing, andthe opening speed is the average speed of the moving contact within 10 ms from the justequinox to 10 ms after the separation.

Application Scenarios

  1. Large Hub Substations

Ideal for 220kV+ key hub substations, the customized RHD breaker controls and protects main power circuits. Its non-standard voltage adaptability ensures seamless integration into existing or upgraded grid architecture.

  1. New Energy Grid-Connection Systems

Suitable for high-voltage grid connections in wind and solar power bases. Custom voltage ratings ensure reliable integration of renewable energy into the main grid, even in projects with unique voltage requirements.

  1. Industrial High-Voltage Power Systems

Perfect for heavy industries (metallurgy, chemicals) with specialized voltage needs. The breaker’s robust performance and customizability guarantee stable power supply for high-power industrial equipment.

 

 

 

Dokümantasyon Kaynak Kütüphanesi Dead Tank Circuit Breaker

Restricted
RHD-Dead Tank SF6 Circuit Breaker Catalog RHD-Dead Tank SF6 Circuit Breaker Catalog
Catalogue
English
PDF
Restricted
138kV Dead-Tank Circuit Breaker Technical Specification | IEC Compliant 138kV Dead-Tank Circuit Breaker Technical Specification | IEC Compliant
Technical Data
Chinese
PDF
Restricted
138kV Dead‑Tank Circuit Breaker Technical Specification | IEEE & ANSI Compliant 138kV Dead‑Tank Circuit Breaker Technical Specification | IEEE & ANSI Compliant
Technical Data
English
PDF
Restricted
2026 RHD Dead tank SF6 gas circuit breaker 2026 RHD Dead tank SF6 gas circuit breaker
Catalogue
English
PDF
Public.
Rockwill Electric Group Profile Rockwill Electric Group Profile
Brochure
English
Public.
RHD-362 SF6 Gas Dead tank Circuit Breaker FLYER RHD-362 SF6 Gas Dead tank Circuit Breaker FLYER
Brochure
English
Public.
RHD-420 SF6 Gas Dead tank Circuit Breaker FLYER RHD-420 SF6 Gas Dead tank Circuit Breaker FLYER
Brochure
English
Public.
RHD-362 SF6 Gas Dead tank Circuit Breaker RHD-362 SF6 Gas Dead tank Circuit Breaker
Drawings
English

Sıkça Sorulan Sorular

Tam Tank Yapısı:

  • Tam Tank Yapısı: Kesici aralığındaki körük söndürme odası, yalıtım ortamı ve ilgili bileşenler, bir yalıtım gazı (örneğin, sülfür hekzaflorür) veya yalıtım yağı ile doldurulmuş metal tank içinde mühürlenir. Bu, nispeten bağımsız ve mühürlü bir alan oluşturarak, iç bileşenleri etkileyebilecek dış çevresel faktörleri etkili bir şekilde önler. Bu tasarım, ekipmanın yalıtım performansını ve güvenilirliğini artırır, çeşitli sert dış ortamlara uygun hale getirir.

Körük Söndürme Odası Düzeni:

  • Körük Söndürme Odası Düzeni: Körük söndürme odası genellikle tankın içinde yerleştirilir. Yapı, sınırlı bir alanda etkili körük söndürmeyi sağlayacak şekilde kompakt olarak tasarlanmıştır. Farklı körük söndürme ilkelerine ve teknolojilerine bağlı olarak, körük söndürme odasının spesifik yapısı değişebilir, ancak genellikle kontaktlar, püskürtücüler ve yalıtım malzemeleri gibi ana bileşenleri içerir. Bu bileşenler, kesici akımı keserken körüğü hızlı ve etkili bir şekilde söndürmek için birlikte çalışır.

İşletme Mekanizması:

  • İşletme Mekanizması: Yayla çalışan mekanizmalar ve hidrolikle çalışan mekanizmalar yaygın olarak kullanılan mekanizmalardır.

  • Yayla Çalışan Mekanizma: Bu tür mekanizma yapısal olarak basit, oldukça güvenilir ve bakım kolaydır. Yayların enerji depolama ve serbest bırakma yoluyla kesicinin açma ve kapatma işlemlerini sağlar.

  • Hidrolikle Çalışan Mekanizma: Bu mekanizma, yüksek çıkış gücü ve düzgün çalışma avantajları sunar, bu nedenle yüksek gerilimli ve yüksek akımlı sınıf kesiciler için uygundur.

1. Güç ağı seviyesine göre nominal voltajla eşleşen devre kesiciyi seçin
Standart voltaj (40.5/72.5/126/170/245/363/420/550/800/1100kV) güç ağı ile uygun nominal voltajla eşleştirilir. Örneğin, 35kV güç ağı için 40.5kV devre kesici seçilir. GB/T 1984/IEC 62271-100 gibi standartlara göre, nominal voltajın güç ağının maksimum çalışma voltajından ≥ olması sağlanır.
2. Standart olmayan özelleştirilmiş voltaj uygulama senaryoları
Standart olmayan özelleştirilmiş voltaj (52/123/230/240/300/320/360/380kV), eski güç ağı yenileme ve belirli endüstriyel güç senaryoları gibi özel güç ağı için kullanılır. Uygun standart voltajın olmaması nedeniyle üreticiler güç ağı parametrelerine göre özelleştirmek zorundadır ve özelleştikten sonra yalıtım ve arka söndürme performansının doğrulanması gerekir.
3. Yanlış voltaj seviyesini seçmenin sonuçları
Düşük bir voltaj seviyesi seçilmesi yalıtım çökertmesine neden olabilir, bu da SF sızıntısına ve ekipman hasarına yol açar; Yüksek bir voltaj seviyesi seçilmesi maliyetleri önemli ölçüde artırır, işletim zorluklarını artırır ve ayrıca performans uyumsuzluğu sorunlarına da neden olabilir.

Tedarikçilerinizi Tanıyın

Çevrimiçi Mağaza
Zamanında teslim oranı
Tepki süresi
100.0%
≤4h
Şirket Genel Bakış
Çalışma Alanı: 108000m² Toplam Çalışan Sayısı: 700+ En Yüksek Yıllık İhracat (usD): 150000000
Hizmetler
İş Tipi: Tasarım/Üretim/Satış
Ana Kategoriler: Trafomüsterge/Paket Trafo Merkezi ve Prefabrik Elektrik Odası/Yıldırıma Karşı Yalıtım ve Yıldırım Koruması/Yüksek Gerilimli Elektrik Ekipmanları/Elektrik Panelleri ve Kontrol Cihazları/Trasformatör
Talep
+86
Dosya yüklemek için tıklayın
İndir
IEE Business Uygulamasını Al
IEE-Business uygulamasını ekipman bulmak için kullanın çözümler elde edin uzmanlarla bağlantı kurun ve sektör işbirliğine katılın her yerde her zaman güç projelerinizin ve işlerinizin gelişimini tamamen destekleyerek
Giriş
veya devam et
Burada yeni misiniz?
Kayıt