2026 RHD Dead tank SF6 gas circuit breaker
SF6 dead‑tank circuit‑breaker, voltage range 11‑550kV, rated current 1600‑5000A, short‑circuit breaking current 25‑63kA, self‑blast arc‑extinguishing, spring‑operated mechanism for outdoor substation.
SF6 dead‑tank circuit‑breaker, voltage range 11‑550kV, rated current 1600‑5000A, short‑circuit breaking current 25‑63kA, self‑blast arc‑extinguishing, spring‑operated mechanism for outdoor substation.
This 2026‑version PDF product manual serves for tendering, equipment selection, substation engineering design and on‑site installation‑maintenance reference.
The equipment complies with IEC 62271‑100, GB/T 1984 and related CEI, JB, DL standards. This manual explains self‑blast arc‑extinguishing operating principle, single‑/three‑phase post‑type porcelain‑insulator structure, dual‑seal flange design and pointer‑type density relay for gas condition monitoring.
It lists complete performance indicators including partial discharge value, SF₆ alarm‑blocking pressure, allowable gas moisture content, annual gas leakage rate ≤0.5%, mechanical endurance up to 10000 operations, special reclosing duty O‑0.3s‑CO‑180s‑CO and full set of timing parameters.
It defines service environmental conditions covering ‑40℃~+55℃ ambient temperature, maximum installation altitude of 3000 m and seismic resistance up to 9‑degree intensity, and provides outline dimension drawings, power‑supply requirements for heater, energy‑storage motor and control circuit, after‑sales service instructions. Custom‑built design, assembly and testing solutions are available. P
lease contact us for editable CAD files and complete type‑test reports.
230-252kV Dead-Tank SF6 Breaker: 9-degree seismic, ≤1% leakage. High-reliability for 220kV+ grids & new energy bases.
420kV Dead Tank SF6 Circuit Breaker provides high reliability and fast arc extinction for stable grid operation with a robust design.
Dead Tank SF6 Circuit Breaker (550kV) offers high performance and reliable arc interruption. Its robust design ensures stability for ultra high voltage systems.
SF6 gazı aşırı düşük sıcaklıklarda sıvılaşabilir ve bu durum ark söndürme performansını düşürebilir. Soğuk bölge projeleri için uygun teknik önlemler alınmalıdır. Düşük sıcaklık çözümleri için lütfen bizimle iletişime geçin.
Ortam sıcaklığı aralığına, yükseklik düşürme gereksinimine, sismik şiddete ve ortam kirlilik sınıfına dikkat ediniz. Standart koşulların dışındaki durumlar için özel modifikasyonlar gereklidir. Ortama uyum önerileri için lütfen bizimle iletişime geçiniz.
Çift contalı tasarım, su geçirmez dış halkayı ve gaz geçirmez iç halkayı ayırarak SF6 gazı sızıntısını etkili bir şekilde azaltır ve dış ortam çevresel uyumluluğunu artırır. Yapısal çizim referansı için lütfen bizimle iletişime geçin.