• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


RHP-145+PT Hybrid Gas Insulated Switchgear
Çizim · ROCKWILL

RHP-145+PT Hybrid Gas Insulated Switchgear

**Brand: ROCKWILL** >132kV transmission substations, solar/wind farm booster stations, urban power grid, projects requiring bay-side voltage measurement without separate outdoor PT.

Son Güncelleme2026.09
DilEnglish
DosyaPDF · 282.8 KB
Hybrid Gas Insulated Switchgear

Belge Açıklaması

With the development of the power industry, the miniaturization of power equipment is the trend of future development and also the urgent need of current power users. Miniaturized electrical equipment can not only save and and civil engineering costs, etc., but also reduce the use of greenhouse gas SF6, meeting the requirements of the environmental protection situation. Combining years of high-voltage electrical design experience and absorbing the world's most advanced technical design concepts, our company has developed the latest generation of gasinsulated metal composite combined electrical appliance (HGIS). This combined electrical appliance has a compact structure and is particularly suitable for urban and mountainous substations. It is also the best choice for the renovation of old substations. In addition, this product is also very suitable for 40.5kV digital substations and can be used as digital electrical equipment.

RHP-145+PT is ROCKWILL segregated-tank hybrid gas insulated switchgear (HGIS) rated at 145kV, complying with IEC 62271-203, IEC 62271-100, IEC 61869 and KEMA type tested. It adopts self-blast SF6 circuit breaker with bistable spring or spring-hydraulic operating mechanism. Available rated current:2000A,2500A,3150A; rated short-circuit breaking current:31.5kA,40kA,50kA. Differing from standard RHP-145, this version integrates PT (voltage transformer) inside the SF6 tank alongside CB, DS, ES and CT, while main busbar uses air insulation. It provides integrated voltage & current signals for metering, protection and synchronism check. Widely used in 132kV transmission substations, renewable energy booster stations and urban power grid projects requiring bay voltage measurement

İlgili Ürünler

Sıkça Sorulan Sorular

  1.  Arazi tasarrufu: AIS'e göre 40%-60% iz bırakma tasarrufu;
  2. Maliyet avantajı: GIS yatırımından %30 düşük ve toplam yatırımdan %45 - %50 düşük;
  3. Az bakım: 25 yıl bakımsız, mekanik ömrü 6000 kez;
  4. Çevre koruması: GIS'in sadece %20'si kadar SF6 kullanımı, yıllık sızıntı oranı ≤ 0,5%.
  1. Tam dijitalleşme: Bilgi toplama, iletim ve işleme tamamen dijitaldir, kabloların yerine optik fiber kablolar kullanılır;
  2. Yüksek uyumluluk: IEC 61850 standardına uygun olarak, cihazlar birbirleriyle bağlantılı ve birlikte çalışabilirler;
  3. Genişletmeye kolay: Yeni özellikler mevcut cihazların değiştirilmesini gerektirmez, sadece ağa bağlanmaları yeterlidir.

IEC uluslararası standartlarına tam olarak uygundur. Kısmi deşarj ≤3pC olan optimize edilmiş elektrik alan tasarımını, standartlaştırılmış uzun ömürlü yay mekanizmasını (6000 döngü) ve yanlış işletim risklerini ortadan kaldırmak için eksiksiz beş önleme mekanik kilitleme sistemini benimser. Yıllık SF6 sızıntı oranı ≤%0,5 olup, şebekenin istikrarlı ve güvenli işletimini sağlar.

WhatsApp
Talep
+86
Dosya yüklemek için tıklayın
İndir
IEE Business Uygulamasını Al
IEE-Business uygulamasını ekipman bulmak için kullanın çözümler elde edin uzmanlarla bağlantı kurun ve sektör işbirliğine katılın her yerde her zaman güç projelerinizin ve işlerinizin gelişimini tamamen destekleyerek
Giriş
veya devam et
Burada yeni misiniz?
Kayıt