13.8‑36 kV pole‑mounted smart auto‑recloser, 560A rated continuous current, 12kA short‑circuit breaking, programmable 1‑4 reclosing sequences, IP65 RTU, multi‑protocol communication & cyber‑security features for 60 Hz overhead distribution‑network.

Última atualização2026.09
IdiomaEnglish
ArquivoPDF · 447 KB
Saudi Electricity Company(SEC)SpecificationSmart Auto-Recloser

Descrição do Documento

This PDF is Saudi Electricity Company utility‑grade technical specification for pole‑mounted smart medium‑voltage auto‑recloser, for EPC contractors, bidders and design‑institutes for tender response, technical gap‑analysis and pre‑award evaluation. The pole‑mounted auto‑recloser complies with IEC 62271‑100, IEEE C37.60, IEC 60870‑5, IEC 61850 and SEC local project requirements.

Key ratings cover 13.8‑36 kV, 560A continuous current, 12kA 3‑second short‑time withstand & breaking capacity, adjustable phase‑trip, earth‑fault and sensitive earth‑fault thresholds, 1‑4 configurable trip‑reclose‑lockout sequences.

It adopts vacuum / SF6 interrupting medium, stainless‑steel tank, polymer bushings, independent IP65 tropical‑rated RTU supporting local‑HMI and remote SCADA control, multi‑communication protocols including DNP3.0, IEC 60870‑5‑101/104, IEC 61850, cellular / fiber / PLC media access, comprehensive cyber‑security controls such as access‑control, audit‑logging and encryption. Integrated VT/CT sensors provide metering & protection signals; maintenance‑free backup battery offers minimum 8‑hour runtime with 50 switching operations under power‑loss condition.

This specification defines full mechanical‑structural requirements, marking (English+Arabic), type‑test / routine‑test / sample‑inspection rules, 5‑year product guarantee, spare‑parts scope, on‑site training obligation and complete tender‑phase & post‑award document deliverables including clause‑by‑clause compliance matrix, type‑test‑reports, CAD drawings, bilingual user‑manual and technical‑data‑schedule.

Custom‑parameter tuning, accessory adaptation and project‑specific FAT can be performed for hot‑climate overhead‑distribution tender projects. Please contact us for compliance‑check template and full qualification documents.