• ​Digital Multi-function Power Meter
  • ​Digital Multi-function Power Meter
  • ​Digital Multi-function Power Meter
​Digital Multi-function Power Meter
$15.00
Model
RQY-72E
RQY-80E
RQY-96E
Basic info
Brand Wone Store
Model NO. ​Digital Multi-function Power Meter
size 72*72mm
Series RQY
Product Detail

The Digital Multi-function Power Meter is a modern power monitoring core device that integrates high-precision measurement, comprehensive monitoring, and intelligent communication. Utilizing a clear and intuitive digital display interface, it provides full-spectrum real-time data of the power system for you. It is the ideal choice for realizing fine-grained energy consumption management, enhancing operational efficiency, and ensuring power supply security in industrial automation, building management, data centers, and power distribution systems.

Core Functions, At a Glance:

  • Precision Measurement: Monitors critical electrical parameters including three-phase/single-phase voltage, current, active/reactive/apparent power, power factor, frequency, etc., in real-time, with leading accuracy (high precision).

  • Energy Metering: Accurately meters active energy and reactive energy (import/export), providing a reliable basis for energy consumption analysis and billing.

  • Power Quality Insight: Offers optional monitoring of power quality parameters such as harmonic content, voltage/current unbalance, etc., aiding in optimizing power supply quality.

  • Clear Display: Employs a high-brightness LED or LCD display (typically dual-row or multi-row), presenting data clearly and intuitively with rich information, facilitating fast on-site reading.

  • Flexible Communication: Integrates standard communication interfaces such as RS485, supporting mainstream industrial protocols like Modbus-RTU, Profibus, CANopen (depending on model configuration), enabling seamless integration into SCADA, EMS, BMS and other systems for remote monitoring and data acquisition (SCADA).

  • Intelligent Alarming: Provides out-of-limit alarm functionality, promptly detecting potential risks such as voltage anomalies or current overload.

  • Data Logging: Certain models feature historical data logging capability, facilitating history tracing and analysis.

Product Advantages, Worthy of Trust:

  • High Accuracy and Reliability: Ensures stable measurements and accurate, trustworthy data, meeting high-standard application requirements.

  • Comprehensive Function Integration: Addresses multiple monitoring needs with a single meter, reducing installation complexity and cost.

  • Convenient and Flexible Installation: Offers multiple form factors (square or DIN-rail mounted), allowing easy adaptation to various distribution panels/cabinets (switchboard/cabinet).

  • Powerful Compatibility: Utilizes standard communication protocols, ensuring easy integration with existing systems.

  • Rugged and Durable: Features an industrial-grade design, wide operating temperature range (e.g., -25°C to +70°C), and strong interference resistance (high immunity).

  • Assists Energy Efficiency Enhancement: Provides precise data support for energy audits and energy-saving renovations.

Technical Specifications:

Parameter Specification
Connection Three-phase four-wire Y34 / Three-phase three-wire V33
Signal Input - Voltage Range 400V / 100V
Signal Input - Voltage Overload Continuous: 1.2x, Instantaneous: 2x
Signal Input - Voltage Consumption < 1VA
Signal Input - Current Range 5A / 1A
Signal Input - Current Overload Continuous: 1.2x, Instantaneous: 2x
Signal Input - Current Consumption < 1VA
Frequency 40-65Hz
Power Supply AC220V (default) or AC/DC 80-270V
Energy Pulse Output Passive optocoupler collector output
Pulse width: 80ms ±20%
Communication • Interface: RS485 (physically isolated)
       • Protocol: MODBUS-RTU
       • Baud rate: 1200-9600 bps
       • Parity: N81/E81/O81
Analog Output • Range: 0/4-20mA or 0-5/10V
       • Configurable variables via programming
Relay Output • Type: Programmable alarm/trip relay
       • Rating: 5A/250V AC, 5A/30V DC
       • Trigger sources: Battery alarm, DI, AI, remote
Digital Input (DI) • Type: Dry contact
       • Function: Programmable alarm mapping
Accuracy Class • Voltage/Current: 0.5
       • Active Energy: 0.5S
       • Reactive Energy: 1.0
       • Frequency: ±0.1Hz
Display High-definition LCD (integrated nixie tube type)
Environmental • Operating: -10°C to +55°C
       • Storage: -20°C to +75°C
Safety Standards • Insulation resistance: >5MΩ (signal/power/earth)
       • Dielectric strength: >2kV AC (signal/power/output)

Wiring diagram:
  Wiring diagram.png


Know your supplier
Wone Store
Main Categories
High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment/Instrument Transformer/Equipment Parts
Business Type
Sales
Highest Annual Export (USD)
$300000000
Professional Experience
1 years
Workplace
1000m²
占位
占位
Related Products
Related Knowledges
Research and Application of Communication Security Strategies for Smart Meters
Research and Application of Communication Security Strategies for Smart Meters
1. Security Threats Facing Smart Meter Communications1.1 Physical Layer Security ThreatsPhysical layer security threats refer to factors that damage or interfere with the hardware devices and physical connections of smart meters, directly affecting their normal operation and data transmission. From the perspective of equipment damage, harsh natural environments such as lightning strikes, floods, and earthquakes can directly destroy the hardware circuits and structures of smart meters, rendering
Echo
09/01/2025
Analysis of Issues and Causes in Smart Meter Testing
Analysis of Issues and Causes in Smart Meter Testing
1. Issues and Cause Analysis in Smart Electricity Meter TestingDuring the verification of smart electricity meters, inspections must be conducted on the meter’s appearance, as well as the clarity and integrity of nameplate markings. Additionally, careful checks are required for physical damage and whether the display can show digits completely. A power-on inspection is also necessary. If error codes appear on the display after power-up, faults should be identified and addressed according to the
Oliver Watts
09/01/2025
Analysis of Common Operational Fault Causes in Smart Electricity Meters
Analysis of Common Operational Fault Causes in Smart Electricity Meters
With the continuous development of smart grids, smart electricity meters are being increasingly widely applied, and various types of operational faults in smart meters are frequently encountered in energy measurement work. This paper analyzes the causes of smart meter failures and proposes corresponding solutions, using several actual operational fault cases as examples.1. Black ScreenA black screen refers to a powered meter with no display, which is the most commonly occurring fault in field-op
Felix Spark
09/01/2025
What tests are required for a qualified smart electricity meter?
What tests are required for a qualified smart electricity meter?
In today's world, not wearing a watch is no longer unusual, but not having an electricity meter is a serious issue. As a measuring instrument vital to people's daily lives, the electricity meter is an essential tool for power consumption measurement and billing in every household. According to current national strategic requirements for smart grid development, smart electricity meters have been widely applied and promoted, bringing entirely new and extensive market opportunities to the metering
Oliver Watts
09/01/2025
Discussion on Fault Diagnosis and Handling Technologies for Smart Meters in Electricity Inspections
Discussion on Fault Diagnosis and Handling Technologies for Smart Meters in Electricity Inspections
1 Analysis of Smart Meter Faults and Their Impact on the Power Grid1.1 Introduction to Smart Meter Functions and Their Critical Role in Modern Power GridsSmart meters exchange data in real time with power companies through two-way communication, enabling functions such as remote meter reading and dynamic tariff adjustment. This capability allows users to adjust their consumption based on real-time pricing, achieving energy savings and cost reduction. Meanwhile, smart meters support grid automati
Felix Spark
09/01/2025
Analysis of the Integrated Application of Smart Meters and Meter Reading, Verification, and Billing Information Systems
Analysis of the Integrated Application of Smart Meters and Meter Reading, Verification, and Billing Information Systems
Meter reading, verification, and billing are critical operations for power companies, and their efficiency directly impacts the company's sustainable development. In recent years, with the widespread adoption of intelligent technologies, smart meters have been promoted and applied in power companies, driving transformation in meter reading and billing operations. The integrated application of smart meters and meter reading, verification, and billing information systems has become a key developme
Echo
09/01/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!