• MC Series Flexible Cable For Coal-mining
  • MC Series Flexible Cable For Coal-mining
MC Series Flexible Cable For Coal-mining
discuss personally
Model
TYPE A MC-0.38/0.66
Basic info
Brand Wone
Model NO. MC Series Flexible Cable For Coal-mining
Rated voltage 0.38/0.66kV
芯数 3+1+3-core
alloy code TU2
Series MC
Product Detail

Application

It is suitable for rated voltage Uo/U 1.9/3.3KV coalmining machine and the similar equipments.

Application conditions

The long-term permissible working temperature of cable conductor for rated voltage up to and including 0.38/0.66kV is 90 ,Black jacket.

The long-term permissible working temperature of cable conductor for rated voltage up to and including 0.66/1.44kV is 90 ,Yellow jacket . and that of the cable conductor of rated voltage1.9/3.3kV is 90℃ It’s smallest bending radiusis 6 times than the size of cable diameter. The yellow sheathed cables can’t be exposed in the sun for a long time.

Model and names

用途.png

Structure diagram

结构.png

Specification size

Rated voltage 0.66/1.14kV cable dimensions

规格.png

Rated voltage 0.38/0.66kV cable dimensions

规格2.png

 Rated voltage 1.9/3.3kV cable dimensions

规格3.png

Technical parameter

Finished DC resistance

 技术特性1.png

Finished insulation resistance

技术特性2.png

    a. Conductor temperature of  90℃ to allow work;

    b. it has the anti-bending characteristics;

    c. it has the anti-extrusion and anti-pressure characteristics;

    d. Insulation tensile strength greater than 6.5Mpa, more than 200% elongation;

    e. Max anti-bending 11.0 N/mm2, Max anti-tensible force>250%;

    f. No damage under rated voltage 0.38/0.66kV for 3.0kV/5min,0.66/1.14kV for 3.7kV/5min, 1.9/3.3kV for 6.8kV/0.5min respectively;

    g. It complies with fire-proof feature based on MT386-1995.


Q: What is MC cable? 

A: MC Cable is Metal Clad Cable. It consists of a combination of insulated wires and is covered with a metal sheath. This cable has good mechanical protection performance and can resist external physical damage such as extrusion and collision to a certain extent. 

Q: What are the main application scenarios of MC cables? 

A: MC cable is often used in commercial buildings, industrial facilities, mining sites and other places. In commercial buildings, such as shopping malls, office buildings, etc., it can be used for electrical wiring systems to power lighting, sockets and other equipment. In industrial facilities, such as factory floors, due to the complex environment, the metal sheathing of MC cables can provide additional protection and is suitable for connecting power to various types of machines and equipment. Because of its excellent defensive performance, it is often used in mining, metallurgy and other fields. 

Q: What are the advantages of MC cable? 

A: Its advantages include high safety, metal sheath can be used as a grounding path; The installation is relatively flexible, and can be laid under a variety of ways such as bridge and cable trough. And has a good electromagnetic compatibility, can reduce the electromagnetic interference to the surrounding equipment.



Know your supplier
Wone
Main Categories
High voltage/Low voltage/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$50,000,000
Professional Experience
1 years
Workplace
65666m²m²
占位
占位
Related Products
Related Knowledges
Analysis of Transformer Capacity, Load Rate and Number of Units Selection Issues
Analysis of Transformer Capacity, Load Rate and Number of Units Selection Issues
The safe and economical operation of power transformers is related to the safety, economy, stability, and reliability of the operations of various industries. The limitations of conditions such as the investment economic indicators for its selection, the economic benefits of maintenance and operation, and the adaptability in the new environment (access of distributed power sources, configuration of energy storage, etc.) make it impossible to include comprehensive factors in other aspects.The cap
Leon
07/17/2025
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
1 IntroductionLow - voltage current transformers for metering, with a through - core type epoxy resin structure, are widely used in distribution transformer areas and for small - to - medium - sized industrial and commercial electricity consumption. As a range expander for electric energy metering, their performance directly relates to electricity consumption safety and the accuracy of users' trade calculations. Studying long - term immersion's impact on these transformers is practically signifi
Felix Spark
07/17/2025
What is reactive power measurement?
What is reactive power measurement?
The power which exists in the circuit when the voltage and current are out of phase to each other, such type of power is known as the reactive power. The formula measures the reactive power in the circuitReactive Power Measurement & VarmetersReactive power measurement is critical as it indicates circuit power loss: low reactive power worsens load power factor, increasing system losses. Varmeters (volt-ampere reactive meters) measure reactive power and are categorized by circuit phases:Single
Edwiin
07/17/2025
How to Design and Install a Solar PV System?
How to Design and Install a Solar PV System?
Design and Installation of Solar PV SystemsModern society relies on energy for daily needs like industry, heating, transport, and agriculture, mostly met by non-renewable sources (coal, oil, gas). However, these cause environmental harm, are unevenly distributed, and face price volatility due to limited reserves—driving demand for renewable energy.Solar energy, abundant and capable of meeting global needs, stands out. Standalone PV systems (Fig 1) offer energy independence from utilities.
Edwiin
07/17/2025
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
Low-voltage current transformers, as indispensable measurement and protection devices in power systems, often encounter various faults when used in combination with other power equipment due to environmental factors, equipment linkage issues, and improper installation and maintenance. These faults not only affect the normal operation of power equipment but may also endanger personal safety. Therefore, it is necessary to gain an in-depth understanding of fault types, judgment methods, and prevent
Felix Spark
07/17/2025
What are the monitoring methods and future development trends of low-voltage voltage transformers?
What are the monitoring methods and future development trends of low-voltage voltage transformers?
With the continuous advancement of smart grid technology, intelligent monitoring systems are playing an increasingly important role in preventing and addressing faults in voltage transformers. These modern intelligent monitoring systems can collect key parameters from voltage transformers in real time—such as partial discharge levels, temperature, and oil quality—and use data analysis algorithms to assess the health status of the equipment, enabling early fault warnings and precise l
Echo
07/16/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!