VTG Series Triphas Solid State Relays

  • VTG Series Three Phase Solid State Relays
  • VTG Series Three Phase Solid State Relays
  • VTG Series Three Phase Solid State Relays

Attributa principalia

Marca Switchgear parts
Numerus Modeli VTG Series Triphas Solid State Relays
currens operativus nominatus 25Amps
Series VTG

Descriptiones productorum a fornitori

Descriptio

Series VTG triplex solidus status relais (SSR) est dispositivum commutationis sine contactu, specialiter designatum pro controllo oneris triplex industriali. Basatum super technologia semiconductoria, per signa microelectronica currentem magnam on/off controllat, omnino substituens relais mechanicum traditionale. Haec series duos modos operationis integrat: conductionem transversalem nullam et conductionem casualem, supportans latum ambitum currentis de 3 × 25A ad 150A, aptum pro systematis AC 480V/530V, praebensque controllem stabilem altam pro oneribus sicut motoribus triplex et aequipamento calefactionis.

Advantages of VTG series three-phase solid-state relay products:
1. Longa vita et alta fidelitas
Nulla structura contactus mechanicorum, resistentia ad vibrationes, explosiones et corrosionem, cum vita quae potest decuplare vitam relais traditionalium.
2. Fortis performantia anti-interferentiae
Isolatio electrica 2500V pro terminis input/output, compatibilis cum niveis logicis TTL/DTL/HTL, resistens fortiter interventui electromagneticum.
3. Responsum dynamicum
Tolerantia dv/dt magna (>1000V/μ s), controlle precise inductorum onerum start-stop, et suppressio spicarum tensionis.
4. Administratio intelligentis visibilis
Indicatio status input LED, monitoratio real-time signorum controlis, meliorans efficientiam diagnosi defectuum.
5. Controlle compatibilitatis ampli ambitus
Supportat tensio controlis DC 3-32V vel AC 90-280V, compatibilis cum variis fontibus signalis sicut PLC et controller temperaturae.

Application of VTG series three-phase solid-state relay products:
1. Systema automationis industrialis
Controlle start-stop motorum triplex (ventilator, pompa, fascia transportans)
Regulatio potentiae forni electrici calefactoris et aequipamenti constantis temperature
Administratio potentiae machinarum gravis sicut machinae injectionis et compressores
2. Energia et controlle potentiae
Dispositivum commutationis automaticum pro armario distributionis
Systema commutationis capacitoris compensationis potentiae reactivae
Controlle circuiti auxiliaris inverteris photovoltaici
3. Publica facilitates et administratio edificii
Controlle unitatis aeris conditionati triplex pro edificiis
Commutatio potentiae matrix luminis sceni
Dispatchatio potentiae systematis signalis viarum
4. Agri instrumentorum specialium
Modulus potentiae altus instrumentorum medicorum
Aequipamentum electricum environmentalis explosion-proof (chemicum, minatorium)
Dispositivum controlis precisionis temperature laboratori

Selectio Producti

25Amps 40Amps 60Amps 80Amps 100Amps 120Amps 150Amps
3 to 32VDC 480VAC”Z” VTG25DA48Z VTG40DA48Z VTG60DA48Z VTG80DA48Z VTG100DA48Z VTG120DA48Z VTG150DA48Z
3 to 32VDC 480VAC”R” VTG25DA48R VTG40DA48R VTG60DA48R VTG80DA48R VTG100DA48R VTG120DA48R VTG150DA48R
3 to 32VDC 530VAC”Z” VTG25DA53Z VTG40DA53Z VTG60DA53Z VTG80DA53Z VTG100DA53Z VTG120DA53Z VTG150DA53Z
3 to 32VDC 530VAC”R” VTG25DA53R VTG40DA53R VTG60DA53R VTG80DA53R VTG100DA53R VTG120DA53R VTG150DA53R
90 to 280VAC 480VAC”Z” VTG25AA48Z VTG40AA48Z VTG6OAA48Z VTG80AA48Z VTG100AA48Z VTG120AA48Z VTG150AA48Z
90 to 280VAC 480VAC”R” VTG25AA48R VTG40AAT8R VTG6OAA48R VTG80AA48R VTG10OAA48R VTG120AA48R VTG150AA48R
90 to 280VAC 530VAC”Z” VTG25AA53Z VTG40AA53Z VTG6OAA53Z VTG80AA53Z VTG100AA53Z VTG120AA53Z VTG150AA53Z
90 to 280VAC 530VAC”R” VTG25AA53R VTG40AA53R VTG60AA53R VTG80AA53R VTG100AA53R VTG120AA53R VTG150AA53R
ControlVoltage OutputVoltage Rated Operational Current

Specificationes Input

Amplitudo Tensionis Controlis 3 ad 32VDC 90 ad 280VAC
Cursus Ingressus [Max.] 33/56mADC @=5V/12V 13mAAC @=220V
Parametri Ingressus U A
Tensio Obligatoria Ad Extinguendum 1VDC 10VAC
Tensio Obligatoria Ad Accendendum 3VDC 90VAC
Index Parametrorum Limites Specificationis
Tensio Reversa [Max.] -6VDC /

Specificationes de Exitu

Intervallus Frequentialis Hz 47 ad 63
Amplitudo Currus Onus Arms 3×25 3×40 3×60  3×80  3×100 3×120 3×150
Amplitudo Tensionis Onus [480V] Vrms 48 ad 480
Amplitudo Tensionis Onus [530V] Vrms 53 ad 530
Numerus Modeli:VTG Amps 25 40 60  80  100 120 150
Currens Fugae Status Off [Max.] mArms ≤8
dv/dt Status Off [Min.] V/usec 500
Decrescens Tensionis Status On [Max.] Vrms 1.8
Parametri Output Unitates Limites Specificationis
Currens Surge 20mSec [Max.] Arms 300 400 600  800  1000 1200 1500
Resistentia Thermalis, [Rthjc] °C/W 0.75 0.55 0.46  0.38  0.34 0.23 0.23
Overvoltage Transitoria [480V] Vpk ≥1200
Overvoltage Transitoria [530V] Vpk ≥1400
Tempus Extinctionis [Max.]“A” mSec 10
Tempus Extinctionis [Max.]“D” Cycle 1/2
Tempus Ignitionis [Max.]“Z” Cycle 1/2
Tempus Ignitionis [Max.]”R” mSec 1
Cognosce tui fornitori
Venditio Online
Ratio praestabilitae tradendae
Tempus responsionis
100.0%
≤4h
Brevis Descriptio Societatis
Locus Operis: 1000m² Numerus omnium laborantium: Summa Annua Exportatio (USD): 300000000
Locus Operis: 1000m²
Numerus omnium laborantium:
Summa Annua Exportatio (USD): 300000000
Servitia
Genus Negotii: Venditio
Categorias Principales: pars componentium/Instrumenta inspectionis/apparatus electrum altum voltus/Apparatus electri bassa tensione/Instrumenta et mensurae/Instrumenta productiva/Ferramentae electricitatis
Gubernatio vitae
Servitia gestionis curae integralis pro quaestu, usu, conservatione et post-venditionem apparatus electricorum, securitatem operationis, continuationem imperii et usum electricitatis sine cura garantia.
Fornitori instrumentorum praeteritus est certificationem qualificationis platformae et iudicium technicum, ut ex fonte conformitas, professionalitas et fiducia servantur.

Producta Connexa

Cognitio Connexa

  • Culpae et Tractatio Terrae Unipolaris in Lineis Distributionis 10kV
    Characteristica et Instrumenta Detegendi Defectus Terrae Monofasiales1. Characteristica Defectuum Terrae MonofasialiumSigna Centralia Admonitionis:Campanula admonitionis sonat, et lucerna indicativa inscripta „Defectus Terrae in Sectione Omnibus [X] kV [Y]“ accenditur. In systematibus ubi punctum neutrum per bobinam Petersen (bobinam suppressionis arcus) ad terram connectitur, lucerna indicativa „Bobina Petersen Operatur“ etiam accenditur.Indicationes Voltmetri Monitoris Isolationis:Tensio phase
    01/30/2026
  • Modus operationis terre iunctae puncti neutralis pro transformatoribus retis electricitatis 110kV~220kV
    Dispositio modi operis terrae puncti neutralis pro transformatoribus rete electricitatis 110kV~220kV debet exigentias tolerationis insulationis puncti neutralis transformatorum complere, et simul conari ut impedimentum sequentiae nullae stationum transformationis fere immutatum maneat, dum certatur ne impedimentum sequentiae nullae compositum in quocumque puncto raptus circuiti systematis ultra ter impedimentum sequentiae positivae compositum excedat.Pro transformatoribus 220kV et 110kV in novis
    01/29/2026
  • Cur Quare Substationes Lapidem Gravem Calculos et Rupem Fractam Utuntur
    Cur Quare Substationes Utuntur Lapidibus, Gravibus, Piscinis et Saxis Tritis?In stationibus transformationis, instrumenta ut transformatores electricitatis et distributionis, lineae transmissionis, transformatores tensionis, transformatores currentis et commutatores disiunctionis omnia terram exigunt. Praeter terram, nunc profundius explorabimus cur gravia et saxa trita in stationibus transformationis saepe utuntur. Quamquam videantur ordinaria, isti lapides partem criticam iuxtaque functionalem
    01/29/2026
  • Cur autem nucleus transformatoris tantum in uno puncto terram tangere debet Nonne terra multipuncta fidelius est
    Cur ergo nucleus transformatoris terram tangere debet?In operatione, nucleus transformatoris, simul cum structuris, partibus et componentibus metallicis quae fixant nucleum et spiras, in forti campo electrico situs est. Sub influentia huius campi electrici, potentialem relativum altum ad terram comparatum acquirunt. Si nucleus non terra tangitur, differentia potentialis inter nucleum et structuras claudicantes et vas terratum existet, quae possit ad intermitterentiam dismissionem ducere.Praetere
    01/29/2026
  • Intellegere Terram Neutralis Transformatoris
    I. Quid est Punctum Neutrum?In transformatoribus et generatoribus, punctum neutrum est locus specificus in spira ubi absoluta tensio inter hunc locum et singula terminalia externa aequalis est. In diagrammate infra, punctumOrepraesentat punctum neutrum.II. Cur Punctum Neutrum Terrendum Est?Modus connexionis electricae inter punctum neutrum et terram in systemate AC triphasico diciturmodus terrendi puncti neutri. Hic modus directe afficit:Securitatem, fidem et oeconomiciam retelectrici;Selectione
    01/29/2026
  • Quid est Differentia Inter Transformatores Rectificatores et Transformatores Potentiae?
    Quid est transformator rectificans?"Conversio potentiae" est terminus generalis qui conversionem, inversionem et conversionem frequentiae comprehendit, inter quas conversio praecipue usitatissima est. Apparatus rectificans convertit potentiam AC input in DC output per rectificationem et filtrationem. Transformator rectificans servit ut transformator alimentationis pro talibus apparatibus rectificantibus. In applicationibus industrialibus, plerumque alimenta DC obtinentur per combinandum transfor
    01/29/2026
Non invenisti adhuc opportunos fornitoris ut te inveniant Citationem Nunc Accipe
Non invenisti adhuc opportunos fornitoris ut te inveniant
Citationem Nunc Accipe
Inquiry
+86
Click to upload file
Descarica
Obtine Applicatio Commerciale IEE-Business
Utiliza app IEE-Business ad inveniendum apparatus obtinendumque solutiones coniungendum cum peritis et participandum in collaboratione industriale ubique et semper propter totam supportionem tuorum projectorum electricitatis et negotiorum