• CLMD Series Capacitors unit
CLMD Series Capacitors unit
discuss personally
Model
CLMD45-30/0.38
CLMD45-20/0.38
CLMD45-5/0.38
CLMD45-2.5/0.38
CLMD33S-16/0.23
CLMD33S-10/0.23
Basic info
Brand Wone Store
Model NO. CLMD Series Capacitors unit
Rated voltage 380V
Rated capacity 30KVA
Series CLMD Series
Product Detail

Overview

Design

The building block of each CLMD capacitor unit is a capacitor winding. These windings undergo vacuum treatment to ensure consistent electrical characteristics. Each winding is then placed in a plastic case and

encapsulated in thermo-setting resin in order to obtain a perfectly sealed element. Elements are combined together to form the capacitor unit.

Electrical characteristics

Dielectric losses are less than 0.2 Watt per kvar. Total losses, including discharge resistors, are less than 0.5 Watt per kvar.

Available for single and three-phase systems The elements are placed inside a box made of sheet steel and connected in such a way as to supply the single or three-phase power at the required voltage and frequency.

Safe performance throughout the capacitor’s life
● The dry type dielectric makes the CLMD capacitors leakage free, minimizing the impact on the environment.
● The sheet steel box is filled with vermiculite which is an inorganic, inert and fireproof material that can absorb the energy produced or extinguish any flames in case of a possible defect at the end of an element’s life.
● In the event of a fault developing in the dielectric of the capacitor, the metallized electrode adjacent to the fault is immediately vaporized, thus isolating the fault. The capacitor then continues normal operation. This is commonly called the ‘self-healing’ principle.
● The capacitor windings are provided with a sequential disconnecter ensuring that each element can be reliably and selectively disconnected from the circuit at the end of its life.
● CLMD capacitors are provided with thermal equalizers to ensure effective heat dissipation. Discharge resistors are also included.
● The use of robust terminals minimizes the risk of damage during installation and reduces maintenance requirements.
● The capacitors comply with the requirements of IEC 60831-1 & 2.

High performance in-house metallized film
Completely integrated manufacturing process has resulted in the development of a special high-performance in-house metallized film from which all CLMD capacitors bene-fit. This film gives high breakdown strength, excellent peak cur-rent handling capability, and high capacitance stability and has an optimal self-healing design and a long life.

Technology parameters

Know your supplier
Wone Store
Main Categories
High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment/Instrument Transformer/Equipment Parts
Business Type
Sales
Highest Annual Export (USD)
$300000000
Professional Experience
1 years
Workplace
1000m²
占位
占位
Documents
Restricted.
capacitors CLMD Data sheet
White paper English
Consulting
Related Products
Related Knowledges
Research and Application of Communication Security Strategies for Smart Meters
Research and Application of Communication Security Strategies for Smart Meters
1. Security Threats Facing Smart Meter Communications1.1 Physical Layer Security ThreatsPhysical layer security threats refer to factors that damage or interfere with the hardware devices and physical connections of smart meters, directly affecting their normal operation and data transmission. From the perspective of equipment damage, harsh natural environments such as lightning strikes, floods, and earthquakes can directly destroy the hardware circuits and structures of smart meters, rendering
Echo
09/01/2025
Analysis of Issues and Causes in Smart Meter Testing
Analysis of Issues and Causes in Smart Meter Testing
1. Issues and Cause Analysis in Smart Electricity Meter TestingDuring the verification of smart electricity meters, inspections must be conducted on the meter’s appearance, as well as the clarity and integrity of nameplate markings. Additionally, careful checks are required for physical damage and whether the display can show digits completely. A power-on inspection is also necessary. If error codes appear on the display after power-up, faults should be identified and addressed according to the
Oliver Watts
09/01/2025
Analysis of Common Operational Fault Causes in Smart Electricity Meters
Analysis of Common Operational Fault Causes in Smart Electricity Meters
With the continuous development of smart grids, smart electricity meters are being increasingly widely applied, and various types of operational faults in smart meters are frequently encountered in energy measurement work. This paper analyzes the causes of smart meter failures and proposes corresponding solutions, using several actual operational fault cases as examples.1. Black ScreenA black screen refers to a powered meter with no display, which is the most commonly occurring fault in field-op
Felix Spark
09/01/2025
What tests are required for a qualified smart electricity meter?
What tests are required for a qualified smart electricity meter?
In today's world, not wearing a watch is no longer unusual, but not having an electricity meter is a serious issue. As a measuring instrument vital to people's daily lives, the electricity meter is an essential tool for power consumption measurement and billing in every household. According to current national strategic requirements for smart grid development, smart electricity meters have been widely applied and promoted, bringing entirely new and extensive market opportunities to the metering
Oliver Watts
09/01/2025
Discussion on Fault Diagnosis and Handling Technologies for Smart Meters in Electricity Inspections
Discussion on Fault Diagnosis and Handling Technologies for Smart Meters in Electricity Inspections
1 Analysis of Smart Meter Faults and Their Impact on the Power Grid1.1 Introduction to Smart Meter Functions and Their Critical Role in Modern Power GridsSmart meters exchange data in real time with power companies through two-way communication, enabling functions such as remote meter reading and dynamic tariff adjustment. This capability allows users to adjust their consumption based on real-time pricing, achieving energy savings and cost reduction. Meanwhile, smart meters support grid automati
Felix Spark
09/01/2025
Analysis of the Integrated Application of Smart Meters and Meter Reading, Verification, and Billing Information Systems
Analysis of the Integrated Application of Smart Meters and Meter Reading, Verification, and Billing Information Systems
Meter reading, verification, and billing are critical operations for power companies, and their efficiency directly impacts the company's sustainable development. In recent years, with the widespread adoption of intelligent technologies, smart meters have been promoted and applied in power companies, driving transformation in meter reading and billing operations. The integrated application of smart meters and meter reading, verification, and billing information systems has become a key developme
Echo
09/01/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!