| Brand | Switchgear parts | 
| Numero ng Modelo | Pagsusuri ng Dalawang Kamay na Monitoring Relay | 
| Narirating na pagsasalungat | 50/60Hz | 
| Serye | SAFE | 
Ang SAFE-TWO-HAND safety relay ay isang napakompaktong pambuong layunin na seguridad na device para sa dalawang kamay. Ito ay sumasang-ayon sa EN ISO 13851, type IIIC, at ito ay inilaan para sa paggamit sa mga circuit ng seguridad na disenyo ayon sa EN 60204-1, tulad ng sa mga stamping machines, punch presses, at bending equipment. Dahil sa internal error monitoring nito, ang dual hand safety relays ay maaaring gamitin para sa mga aplikasyon na sumasang-ayon sa safety level 4 ng EN ISO 13849-1, SILCL 3 ng EN 62061, o type III C ng EN ISO 13851.
Safety relay para sa dalawang kamay hanggang SIL3 at Type IIIC
Function
2 ligtas na contact ng relay, input bawat push button 1 N/O, 1 N/C, automatic start, Type IIIC, hanggang SIL 3 / Cat. 4, PL e, 24 V AC/DC, lapad: 22.5 mm
Features
2 N/O Safety Contacts
Two-Hand Push Buttons
SIL CL 3 (EN 62061 / IEC 61508)
Type IIIC (EN ISO 13851)
| Parameter | Specification | 
|---|---|
| In compliance with | EN ISO 13851, EN 60204-1, EN ISO 13849-1, EN 62061 | 
| Operating voltage | AC/DC 24 V +/- 10 % | 
| Power consumption | AC 3.5 VA/DC 1.5 W | 
| Rated supply frequency | 50 - 60 Hz | 
| Control voltage at S11 and S22 | DC 24 V | 
| Control current | typical 2 x 40 mA | 
| Safety contacts non-delayed | 2 NO | 
| Max. switching voltage | AC 250 V | 
| Contact rating of safety contacts
 | 
AC: 250 V, 1500 VA, 6 A for resistive load
 | 
| Max. total current through all contacts | 12 A | 
| Minimum contact load | 5 V, 10 mA | 
| External fuses | 10 A gG | 
| Release time for the safety relays after release of a button | < 20 ms | 
| Response delay after actuation of the buttons | < 20 ms | 
| Synchronization time | 0.5 s | 
| Max. length of control line | 1000 m at 0.75 mm² | 
| Wire width | 0.14 - 2.5 mm² | 
| Tightening moment (Min./Max.) | 0.5 Nm/0.6 Nm | 
| Contact material | AgSnO₂ | 
| Service Life | mech. approx. 1×10⁷ | 
| Test voltage | 2.5 kV (control voltage/contacts) | 
| Rated impulse withstand voltage, leakage path/air gap | 4 kV (DIN VDE 0110-1) | 
| Rated insulation voltage | 250 V | 
| Degree of pollution/Overvoltage category | 2/3 (DIN VDE 0110-0) | 
| Protection | IP20 | 
| Temperature range Ambient | -15 °C to +60 °C (max. +40 °C for AC use) | 
| Temperature range Storage | -15 °C to +85 °C | 
| Max. altitude | ≤ 2000 m (above sea level) | 
| Weight approx. | 190 g | 
| Mounting DIN rail according to EN 60715 | TH35 |