• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


Transmitter Pressionis Protectus PG208

  • PG208 Protected Pressure Transmitter
  • PG208 Protected Pressure Transmitter
  • PG208 Protected Pressure Transmitter
  • PG208 Protected Pressure Transmitter

Attributa principalia

Marca Wone
Numerus Modeli Transmitter Pressionis Protectus PG208
Fornitio electrica 9~30VDC
Typus pressionis Gauge pressure
monstrare Yes
Series PG208

Descriptiones productorum a fornitori

Descriptio

Describendum

Transmitter pressionis protector utilis wafer importatos silicium, cum praecisione alta et stabilitate; ut elementum sensus, nucleus piezoresistivus silicium internam habet circuitum tractationis, qui signum millivolt sensoris in signum standardis voltage et currentis convertit, et cum instrumento unitario, systema DCS, PLC, etc. ad formandum systema automaticum controlis, quod est instrumentum mensurae pressionis ideale in campo automationis industrialis. Est instrumentum mensurae pressionis ideale in campo automationis industrialis ad formandum systema automaticum controlis.

Applicationes industriales

Largiter in variis campis industrialibus (equipmenta automationis et petrolei, chemica, naturalis gas, energia, etc.) ubi pressio fluidi mensuranda est usatur.

Characteristica

Technologia diaphragmatis isolationis adoptata est, quae stabilitatem et fiduciam altas habet.

Chip integratus, alimentatio tensio latior.

 Structura integra funditus aluminis, fortis et fidelis.

 Designatio decurtantis frequentiae, resistens forti, protectio fulminis.

Limitatio currentis, limitatio tensionis, protectio polaritatis inversae (limitatio output currentis).

Praecisio alta, stabilitas bona, celeritas responsus et resistencia impactus.

Parametri technici

Medium mensurae Liquida vel aer (compatibilis cum materialibus contactus)
Amplificatio pressionis - 100 kPa ~ 0 ~ 100 MPa
Modus pressionis Pressio gauge, pressio absoluta, pressio negativa
Signum output 4 ~ 20 mA 0 ~ 10 VDC 0 ~ 5 VDC RS 485 customizatum
Tensio alimentaria 9 ~ 30 VDC
Gradus accuratiae ± 0.25 % FS ± 0.5 % FS Accuratia ostendi capitis 0.5-level, tubulus digitalis (LED) ostendendi
Conditiones operativae Temperatura media -40 ~ 80 °C Temperatura ambientalis -40 ~ 80 °C
Performantia seismica 10 g (20 ... 2000 Hz)
Capacitas overload 1.5 vices ~ 5 vices
Frequensia responsus Output signi analogi ≤ 500 Hz et output signi digitalis ≤ 5 Hz
Stabilitas performantiae ± 0.1 % FS/anno
Driftus temperaturae ±0.01 % FS/°C (in compensatione temperaturae)
Protectio ingressus IP 65 IP 66
Typus explosion-proof Flameproof ExdII.CT 6 Gb Intrinsically Safe ExiaII.CT 6 Ga
Caracteristica oneris Oneris currentis ≤{(Us-7.5)÷0.02 (Us=tensio alimentaria)}Ω Oneris tensionis≥ 100 kΩ

Demonstratio producti

企业微信截图_17157381573209.png

企业微信截图_17157381856397.png

     企业微信截图_17157382114987.png

企业微信截图_17157382354458.png




Cognosce tui fornitori
Venditio Online
Ratio praestabilitae tradendae
Tempus responsionis
100.0%
≤4h
Brevis Descriptio Societatis
Locus Operis: 65666m²m² Numerus omnium laborantium: 300+ Summa Annua Exportatio (USD): 50000000
Locus Operis: 65666m²m²
Numerus omnium laborantium: 300+
Summa Annua Exportatio (USD): 50000000
Servitia
Genus Negotii: Design/Fabricatio/Venditio
Categorias Principales: cable et filum/Energia nova/Instrumenta inspectionis/apparatus electrum altum voltus/Aedificii electritas Apparatus electricus/Apparatus electri bassa tensione/Instrumenta et mensurae/Instrumenta productiva/aestus apparatus/Ferramentae electricitatis
Gubernatio vitae
Servitia gestionis curae integralis pro quaestu, usu, conservatione et post-venditionem apparatus electricorum, securitatem operationis, continuationem imperii et usum electricitatis sine cura garantia.
Fornitori instrumentorum praeteritus est certificationem qualificationis platformae et iudicium technicum, ut ex fonte conformitas, professionalitas et fiducia servantur.

Producta Connexa

Cognitio Connexa

  • Accidentia Transformatoris Principalis et Questiones Operationis Gas Luminis
    1. Registri accidentis (XIX Martii, MMXIX)Hora XVI:XIIX die XIX Martii, MMXIX, monitorium background reportavit actionem gas levis transformatoris principis numeri III. Conformiter Codex Operationis Transformatorum Electricitatis (DL/T572-2010), personale operationis et maintenance (O&M) inspectavit statum in situ transformatoris principis numeri III.Confirmatio in situ: Panel non-electricus protectionis WBH transformatoris principis numeri III reportavit actionem gas levis phase B corpus tr
    02/05/2026
  • Culpae et Tractatio Terrae Unipolaris in Lineis Distributionis 10kV
    Characteristica et Instrumenta Detegendi Defectus Terrae Monofasiales1. Characteristica Defectuum Terrae MonofasialiumSigna Centralia Admonitionis:Campanula admonitionis sonat, et lucerna indicativa inscripta „Defectus Terrae in Sectione Omnibus [X] kV [Y]“ accenditur. In systematibus ubi punctum neutrum per bobinam Petersen (bobinam suppressionis arcus) ad terram connectitur, lucerna indicativa „Bobina Petersen Operatur“ etiam accenditur.Indicationes Voltmetri Monitoris Isolationis:Tensio phase
    01/30/2026
  • Modus operationis terre iunctae puncti neutralis pro transformatoribus retis electricitatis 110kV~220kV
    Dispositio modi operis terrae puncti neutralis pro transformatoribus rete electricitatis 110kV~220kV debet exigentias tolerationis insulationis puncti neutralis transformatorum complere, et simul conari ut impedimentum sequentiae nullae stationum transformationis fere immutatum maneat, dum certatur ne impedimentum sequentiae nullae compositum in quocumque puncto raptus circuiti systematis ultra ter impedimentum sequentiae positivae compositum excedat.Pro transformatoribus 220kV et 110kV in novis
    01/29/2026
  • Cur Quare Substationes Lapidem Gravem Calculos et Rupem Fractam Utuntur
    Cur Quare Substationes Utuntur Lapidibus, Gravibus, Piscinis et Saxis Tritis?In stationibus transformationis, instrumenta ut transformatores electricitatis et distributionis, lineae transmissionis, transformatores tensionis, transformatores currentis et commutatores disiunctionis omnia terram exigunt. Praeter terram, nunc profundius explorabimus cur gravia et saxa trita in stationibus transformationis saepe utuntur. Quamquam videantur ordinaria, isti lapides partem criticam iuxtaque functionalem
    01/29/2026
  • Cur autem nucleus transformatoris tantum in uno puncto terram tangere debet Nonne terra multipuncta fidelius est
    Cur ergo nucleus transformatoris terram tangere debet?In operatione, nucleus transformatoris, simul cum structuris, partibus et componentibus metallicis quae fixant nucleum et spiras, in forti campo electrico situs est. Sub influentia huius campi electrici, potentialem relativum altum ad terram comparatum acquirunt. Si nucleus non terra tangitur, differentia potentialis inter nucleum et structuras claudicantes et vas terratum existet, quae possit ad intermitterentiam dismissionem ducere.Praetere
    01/29/2026
  • Intellegere Terram Neutralis Transformatoris
    I. Quid est Punctum Neutrum?In transformatoribus et generatoribus, punctum neutrum est locus specificus in spira ubi absoluta tensio inter hunc locum et singula terminalia externa aequalis est. In diagrammate infra, punctumOrepraesentat punctum neutrum.II. Cur Punctum Neutrum Terrendum Est?Modus connexionis electricae inter punctum neutrum et terram in systemate AC triphasico diciturmodus terrendi puncti neutri. Hic modus directe afficit:Securitatem, fidem et oeconomiciam retelectrici;Selectione
    01/29/2026
Non invenisti adhuc opportunos fornitoris ut te inveniant Citationem Nunc Accipe
Non invenisti adhuc opportunos fornitoris ut te inveniant
Citationem Nunc Accipe
Inquiry
+86
Click to upload file
Descarica
Obtine Applicatio Commerciale IEE-Business
Utiliza app IEE-Business ad inveniendum apparatus obtinendumque solutiones coniungendum cum peritis et participandum in collaboratione industriale ubique et semper propter totam supportionem tuorum projectorum electricitatis et negotiorum