• High-Current Current-Limiting Circuit Breaker/Short-Circuit Current Limiter(FCL)
High-Current Current-Limiting Circuit Breaker/Short-Circuit Current Limiter(FCL)
discuss personally
Model
DDXK1-20/1250
Basic info
Brand RW Energy
Model NO. High-Current Current-Limiting Circuit Breaker/Short-Circuit Current Limiter(FCL)
Rated voltage 20kV
Rated normal current 1250A
Rated frequency 50/60Hz
Series DDXK
Product Detail

Product Introduction

A core protection component for high-capacity power systems (35kV-220kV grids, industrial parks), the FCL responds in ≤10ms to short-circuit faults. It limits peak fault current to 15%-50% of the expected value before safe breaking, shielding generators/transformers. Supporting 630A-4000A current ratings, it fits AC/DC systems and integrates with switchgear for stable grid operation.

Feature

  • High-Speed Interruption: It operates and interrupts the short-circuit current at the front part of the first power frequency half-cycle of the short-circuit current—well before the current rises to its peak. The total interruption time is 2–5 ms, approximately 10–20 times faster than that of conventional circuit breakers.

  • Current-Limiting Interruption: It starts limiting the short-circuit current 1 ms after a short-circuit occurs, and finally restricts the short-circuit current to 15%–45% of the expected value.

  • High Interruption Capacity: The rated prospective short-circuit interruption current ranges from 63 kA to 200 kA, while the rated short-circuit interruption current of currently common circuit breakers usually only reaches 40.5 kA to 50 kA.

  • Built-in Rogowski Current Sensor: It features accurate measurement, fast response speed, and can be arranged in a phase-separated manner or integrated into switchgear cabinets.

  • High Reliability: One of the product’s competitive advantages is its outstanding reliability. Special design and craftsmanship ensure the product’s high reliability, which has been verified and well-received in on-site applications.

Main Parameters

No.

Item


Unit

Technical Parameters

1

Rated Current

A

630~6300

2

Rated Voltage

kV

7.2/12/20/40.5

3

Rated Frequency

Hz

50/60

4

Rated Prospective Short - Circuit Breaking Current

kA

63/80/120

5

Rated Insulation Level (Power Frequency / Lightning)

7.2kV

kV

 23/60 kV

12kV

42/75 kV

20kV

50/125 kV

40.5kV

95/185 kV

6

Breaking Time


ms

2~5ms

7

Cut - off Current / Prospective Short - Circuit Current Peak Value

%

20~45

8

DC Resistance of Main Circuit

μΩ

<40

9

Operating Current Setting Range

kA

6kA~60kA

10

Rated Breaking Current of Fuse

kA

63/120

11

Rated Short - time Withstand Current of Main Circuit

kA/s

31.5/2

12

Rated Peak Withstand Current of Main Circuit

kA

80

Figure 4: Using DDXK1 as rapid short-circuit protection for generators and transformers
(a) Rapid short-circuit protection at the 10kV/35kV side outlet of transformers
(b) Rapid short-circuit protection at generator outlets
(c) Rapid short-circuit protection for power plant branch busbars
(d) Rapid short-circuit protection at grid-connected generator outlets

Know your supplier
RW Energy
Zhejiang Rockwell Energy Technology Co., Ltd. is an international enterprise specializing in the research, development and manufacturing of recloser controllers, power quality management, power monitoring systems and other high-end power equipment. In today's critical period of global energy transition and power system upgrading, the company has gathered a group of top talents in the fields of power engineering, automation control, software development, etc., who carry the enthusiasm and persistence for the power business, and are committed to overcoming the complex problems in the power system, and promoting the intelligent development of the power industry with innovative technology. Mission: To make global electricity smarter, more reliable and more efficient with innovative technology. Vision: To be the leader in global power intelligence.
Main Categories
High Voltage Electrical Apparatus/New energy/Tester
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$100000000
Professional Experience
12 years
Workplace
30000m²
占位
占位
Related Products
Related Knowledges
Technical Analysis of 220 kV High-Voltage Cable Construction in Winter
Technical Analysis of 220 kV High-Voltage Cable Construction in Winter
1.Work Environment Requirements and Safeguard MeasuresBased on technical requirements for cable equipment storage, laying, transportation, laying, transposition, testing, and cable terminations, the project owner and construction units have conducted extensive trials and implemented protective measures regarding ambient temperature, humidity, bending radius, traction control, and route optimization. These measures ensure high-voltage cable quality and on-site safety under harsh winter conditions
James
09/03/2025
Withstand voltage test of high-voltage cables
Withstand voltage test of high-voltage cables
Withstand voltage test is an insulation test, but it is a destructive test that can reveal insulation defects difficult to detect in non-destructive testing.The test cycle for high-voltage cables is three years, and it must be conducted after non-destructive tests. In other words, the withstand voltage test is performed only after all non-destructive tests have been passed.Most high-voltage cables used today are cross-linked polyethylene (XLPE) cables, which can have large cross-sections and cov
Oliver Watts
09/03/2025
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
I. Introduction to Cable Grounding Loop CurrentCables rated 110 kV and above use a single-core structure. The alternating magnetic field generated by the operating current induces a voltage on the metallic sheath. If the sheath forms a closed circuit through the earth, a grounding loop current will flow on the metallic sheath. Excessive grounding loop current (loop current exceeding 50 A, more than 20% of the load current, or a ratio of maximum-to-minimum phase current greater than 3) not only a
Felix Spark
09/03/2025
Considerations and Recommendations for Flame-Retardant Selection of High-Voltage Cables
Considerations and Recommendations for Flame-Retardant Selection of High-Voltage Cables
1.Flame-Retardant Cable Classification StandardsThe flame-retardant standard system is divided into two main categories. The first category follows the "Classification of Burning Behavior for Electric and Optical Fiber Cables" GB 31247. Cables complying with this standard system are widely used in densely populated areas such as high-speed railways and subways. This standard imposes strict requirements on parameters such as smoke density, heat release, and total smoke production, and cables typi
James
09/03/2025
Repair of high-voltage cable metallic sheaths
Repair of high-voltage cable metallic sheaths
I. Functions of Metallic Sheaths and Necessity of RepairThe metallic sheath of high-voltage cables is a metal shielding structure laid outside the insulation layer, including types such as lead sheaths, aluminum sheaths, and steel wire armor. Its core functions include mechanical protection (resisting external impact and compression), electrochemical corrosion protection (isolating moisture and soil pollutants), electromagnetic shielding (reducing electromagnetic interference to the environment)
Felix Spark
09/03/2025
What factors need to be considered when designing a transformer?
What factors need to be considered when designing a transformer?
Transformer design is a complex process that requires consideration of multiple factors to ensure safe and efficient operation. In addition, compliance with international and local regulations is essential to guarantee that transformers meet safety and performance standards. Below are key factors to consider in transformer design and the relevant regulations to follow:Transformer Design Factors: Voltage and Frequency: Determine the input and output voltage levels and the operating frequency. The
Vziman
09/02/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!