• 35kV Short-Circuit Current Limiter
  • 35kV Short-Circuit Current Limiter
35kV Short-Circuit Current Limiter
discuss personally
Model
DDX1-40.5/1250
Basic info
Brand RW Energy
Model NO. 35kV Short-Circuit Current Limiter
Rated voltage 40.5kV
Rated normal current 1250A
Series DDX
Product Detail

Product Introduction

The DDX1 Short-Circuit Current Limiter is a high-speed switch capable of interrupting short-circuit currents. It can break the short-circuit current within 10ms after a short-circuit fault occurs—well before the instantaneous value of the short-circuit current rises to its expected peak.Integrating fast cutting technology, high-voltage current limiting technology, electronic measurement and control technology, and high-voltage insulation technology, it enables rapid current limiting and interruption of short-circuit currents in power generation, distribution, and consumption systems. This protects key power equipment such as generators and transformers from the impact of catastrophic short-circuit currents.Meanwhile, it can also optimize the operation mode of the distribution system, achieving effects such as energy conservation and consumption reduction, improved power quality, and enhanced power supply reliability.

Product Features and Benefits

  • Strong short-circuit breaking capacity (large capacity), rated breaking short-circuit current of 50kA~200kA.

  • Fast breaking speed (high speed), the whole breaking time is less than 10ms.

  • The opening process has obvious current limiting characteristics (current limiting).

  • The action criterion uses the instantaneous value of current and the instantaneous value of current change rate.

  • The current sensor is integrated with a fast isolator for a simplified structure.

  • The electronic controller works independently in three phases through high temperature and strong interference tests to ensure the overall reliability of the product.

Electrical parameters

serial number

Parameter Name

unit

Technical parameters

1

Rated voltage

kV

40.5

2

Rated current

A

630-6300

3

Rated expected short-circuit breaking current

kA

50-200

4

Current limit coefficient = cut-off current / expected short-circuit current peak

%

15~50

5

Insulation level

Power frequency withstand pressure

       kV/1min

95

Lightning impact withstand pressure

           kV

185

Product Applications

  • Bypass current-limiting reactor: Enables energy conservation and consumption reduction, eliminates reactor reactive power, and improves power supply quality.

  • Parallel operation of sectioned busbars in large-capacity distribution systems: Optimizes load distribution and reduces network impedance.

  • Short-circuit protection for generator outlets or transformer low-voltage sides.

  • Short-circuit protection for power plant branch busbars and station service high-voltage transformers.

Know your supplier
RW Energy
Zhejiang Rockwell Energy Technology Co., Ltd. is an international enterprise specializing in the research, development and manufacturing of recloser controllers, power quality management, power monitoring systems and other high-end power equipment. In today's critical period of global energy transition and power system upgrading, the company has gathered a group of top talents in the fields of power engineering, automation control, software development, etc., who carry the enthusiasm and persistence for the power business, and are committed to overcoming the complex problems in the power system, and promoting the intelligent development of the power industry with innovative technology. Mission: To make global electricity smarter, more reliable and more efficient with innovative technology. Vision: To be the leader in global power intelligence.
Main Categories
High Voltage Electrical Apparatus/New energy/Tester
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$100000000
Professional Experience
12 years
Workplace
30000m²
占位
占位
Related Products
Related Knowledges
Technical Analysis of 220 kV High-Voltage Cable Construction in Winter
Technical Analysis of 220 kV High-Voltage Cable Construction in Winter
1.Work Environment Requirements and Safeguard MeasuresBased on technical requirements for cable equipment storage, laying, transportation, laying, transposition, testing, and cable terminations, the project owner and construction units have conducted extensive trials and implemented protective measures regarding ambient temperature, humidity, bending radius, traction control, and route optimization. These measures ensure high-voltage cable quality and on-site safety under harsh winter conditions
James
09/03/2025
Withstand voltage test of high-voltage cables
Withstand voltage test of high-voltage cables
Withstand voltage test is an insulation test, but it is a destructive test that can reveal insulation defects difficult to detect in non-destructive testing.The test cycle for high-voltage cables is three years, and it must be conducted after non-destructive tests. In other words, the withstand voltage test is performed only after all non-destructive tests have been passed.Most high-voltage cables used today are cross-linked polyethylene (XLPE) cables, which can have large cross-sections and cov
Oliver Watts
09/03/2025
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
I. Introduction to Cable Grounding Loop CurrentCables rated 110 kV and above use a single-core structure. The alternating magnetic field generated by the operating current induces a voltage on the metallic sheath. If the sheath forms a closed circuit through the earth, a grounding loop current will flow on the metallic sheath. Excessive grounding loop current (loop current exceeding 50 A, more than 20% of the load current, or a ratio of maximum-to-minimum phase current greater than 3) not only a
Felix Spark
09/03/2025
Considerations and Recommendations for Flame-Retardant Selection of High-Voltage Cables
Considerations and Recommendations for Flame-Retardant Selection of High-Voltage Cables
1.Flame-Retardant Cable Classification StandardsThe flame-retardant standard system is divided into two main categories. The first category follows the "Classification of Burning Behavior for Electric and Optical Fiber Cables" GB 31247. Cables complying with this standard system are widely used in densely populated areas such as high-speed railways and subways. This standard imposes strict requirements on parameters such as smoke density, heat release, and total smoke production, and cables typi
James
09/03/2025
Repair of high-voltage cable metallic sheaths
Repair of high-voltage cable metallic sheaths
I. Functions of Metallic Sheaths and Necessity of RepairThe metallic sheath of high-voltage cables is a metal shielding structure laid outside the insulation layer, including types such as lead sheaths, aluminum sheaths, and steel wire armor. Its core functions include mechanical protection (resisting external impact and compression), electrochemical corrosion protection (isolating moisture and soil pollutants), electromagnetic shielding (reducing electromagnetic interference to the environment)
Felix Spark
09/03/2025
What factors need to be considered when designing a transformer?
What factors need to be considered when designing a transformer?
Transformer design is a complex process that requires consideration of multiple factors to ensure safe and efficient operation. In addition, compliance with international and local regulations is essential to guarantee that transformers meet safety and performance standards. Below are key factors to consider in transformer design and the relevant regulations to follow:Transformer Design Factors: Voltage and Frequency: Determine the input and output voltage levels and the operating frequency. The
Vziman
09/02/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!