NOV-40 protector automaticus pro superet sub tensio

  • NOV-40 self resetting overvoltage and undervoltage protector
  • NOV-40 self resetting overvoltage and undervoltage protector
  • NOV-40 self resetting overvoltage and undervoltage protector
  • NOV-40 self resetting overvoltage and undervoltage protector

Attributa principalia

Marca Switchgear parts
Numerus Modeli NOV-40 protector automaticus pro superet sub tensio
Votum nominatum AC220V
currus electricus nominatus 40A
Frequenta nominata 50/60Hz
Series NOV

Descriptiones productorum a fornitori

Descriptio

NOV typus automatica super- et sub-voltatia protector est intelligenti distributio protectionis dispositivum, cuius principale officium est lineae voltatis monitorare. Cum voltas excesserit securitatis limites (sub-voltatia 140V-210V, super-voltatia 230V-300V), potestas intra 0.5 secundorum automatica intercipitur; postquam voltas ad normam redierit, per praeset temporis moram (regibile a 1-600 secundis) sine manu operante reconnexio fiat. Suae IP20 protectionis gradus conventionalibus distributionis cassetis installationis requirit satisfacit.

NOV typus automatica super- et sub-voltatia protectoris beneficia:
1. Accurata protectio: cum erroris ambitu ± 2%, protectivum agmen est precisum et fidelem.
2. Celer responsus: super- et sub-voltatiae actus mora tantum 0.5 secunda, celeriter periculosam potentiam intercipiens.
3. Flexibilis restitutio sui: regibile tempus restitutionis 1-600 secundis, ad diversarum machinarum renascendi necessitates accommodatum.
4. Durabilis et longaevus: usque ad 100000 electrica circulorum et 1 millionem mechanicorum circulorum, stabilitate praeditus.
5. Lata compatibilitas: ad AC 220V/50-60Hz reticula aptus, cum validitate applicabilitatis.
NOV typus automatica super- et sub-voltatia protectoris characteristica:
1. Latus limen protectio:
Sub-voltatia protectio ab 140V ad 210V, super-voltatia vero ab 230V ad 300V, efficaciter respondens variis voltatia abnormalibus casibus.
2. Alta praecisionis monitoratio:
± 2% erroris controllo, exactus voltatia iudicium, evitans mala operationem vel defluxionis protectionem.
3. Celer responsus mechanismus:
Post anomalam voltatiam detectam, solum 0.5 secundi ad potentiam intercipientem actionem perficiendum opus est, periculum machinarum damni minuens.
4. Intelligentia restitutio:
Flectibilis mora restitutionis regulamenta a 1 secundo ad 600 secundos offerens, ad varias electrica ut aeratorum et refrigerantium compressorum tutum renovandi intervallorum exigentias satisfaciens.
5. Duplex longaevus design:
Electrica elementa habent vita interruptiva 100000 vicibus, structura mecanica vero supportat usque ad 1 millionem operationes, longinqua stabili operatione assecurans.
6. Standardis protectio:
IP20 tegumenti protectio magnas solidas alienas corpora efficaciter prohibet intrare, ad standardis distributionis cassetis ambientes instalationis idoneam.

Bibliotheca Documentorum Rerum
Restricted
NOV-40 Voltage protector
Catalogue
English
Consulting
Consulting
FAQ
Q: Quae sunt principia utilitatis protectoris NOV-40 contra supra et infra tensionem se ipso reparatoris?
A:

·Protectio accurata et celer, sine angulo mortuo pro fluctuationibus voltage: Limitem super-voltus et sub-voltus accurate adiustare potest intra ambitum 230-300V/140-210V, et tempus responsionis trip est tantum 0.5 secundorum, quod potest instanter dissecare circuitum voltagis anormalis ut evitentur insulatio fractura aequipmenti et combustio componentium.

·Reset automaticus et sine cura, laboris costus reductus: Postquam voltagus redit ad normam, ipse reclosetur, nec clausura manualis vel substitutio accessorum requiritur. Praesertim idoneum in scenariis sine custode (sicut PV power stations, equipmenta remote control), operatio et manutentio costus reductus est per 80%.

·Design altae durabilitatis ad operationem stabilius fidelius: Usurpatu conchae ABS flammifugae cum protectione IP20, praetendit pulvere et concussione; vita electrica est ≥10⁵ vices et vita mechanica est ≥10⁶ vices, supportans longam et frequentem protectionem fluctuationis voltagis cum vita servicii plus quam 8 annos.

·Adaptatio scenarii latioris, installatio flexibiliter et efficienter: Compatibile cum AC 80V-400V ampla input voltagis, idonea pro 220V distributione potestatis domesticarum et 380V controlis industrialibus; usurpando installationem DIN rail standard 35mm, compacta est magnitudine et posse densiter disponi cum circuit breakers et relays, reducta tempora installationis per 50%.

Q: Quid est NOV-40 Self-Resetting Overvoltage and Undervoltage Protector?
A:

NOV-40 Sui Se Restituens Protector a Supravoltagine et Subvoltagine est dispositivum electricum intelligentem specialiter pro protectione voltaginis systematum distributionis unipolarium/tripolarium. Cum correntia nominata 40A, id compatibile est cum scenariis voltaginis AC 220V/380V, praebens protectionem dualem supravoltaginis et subvoltaginis pariterque functionem restitutivam automaticam. Quando voltaginis rete superat limen positum (supravoltaginis ≥230-300V/subvoltaginis ≤140-210V), dispositivum cito interrompit circuitum intra 0.5 secundas; postquam voltaginis revertitur ad normam, id potest reclosuram facere automaticam intra 1-600 secundas sine operatione manuali. Latissime usus in distributionibus electricis domesticis, aedificiis commercialibus, controllo industriali, distributione PV et aliis scenariis, id protegit apparatos domesticos et instrumenta precisionis ab damno causato fluctuationibus voltaginis.

Cognosce tui fornitori
Venditio Online
Ratio praestabilitae tradendae
Tempus responsionis
100.0%
≤4h
Brevis Descriptio Societatis
Locus Operis: 1000m² Numerus omnium laborantium: Summa Annua Exportatio (USD): 300000000
Locus Operis: 1000m²
Numerus omnium laborantium:
Summa Annua Exportatio (USD): 300000000
Servitia
Genus Negotii: Venditio
Categorias Principales: pars componentium/Instrumenta inspectionis/apparatus electrum altum voltus/Apparatus electri bassa tensione/Instrumenta et mensurae/Instrumenta productiva/Ferramentae electricitatis
Gubernatio vitae
Servitia gestionis curae integralis pro quaestu, usu, conservatione et post-venditionem apparatus electricorum, securitatem operationis, continuationem imperii et usum electricitatis sine cura garantia.
Fornitori instrumentorum praeteritus est certificationem qualificationis platformae et iudicium technicum, ut ex fonte conformitas, professionalitas et fiducia servantur.

Producta Connexa

Cognitio Connexa

  • Accidentia Transformatoris Principalis et Questiones Operationis Gas Luminis
    1. Registri accidentis (XIX Martii, MMXIX)Hora XVI:XIIX die XIX Martii, MMXIX, monitorium background reportavit actionem gas levis transformatoris principis numeri III. Conformiter Codex Operationis Transformatorum Electricitatis (DL/T572-2010), personale operationis et maintenance (O&M) inspectavit statum in situ transformatoris principis numeri III.Confirmatio in situ: Panel non-electricus protectionis WBH transformatoris principis numeri III reportavit actionem gas levis phase B corpus tr
    02/05/2026
  • Culpae et Tractatio Terrae Unipolaris in Lineis Distributionis 10kV
    Characteristica et Instrumenta Detegendi Defectus Terrae Monofasiales1. Characteristica Defectuum Terrae MonofasialiumSigna Centralia Admonitionis:Campanula admonitionis sonat, et lucerna indicativa inscripta „Defectus Terrae in Sectione Omnibus [X] kV [Y]“ accenditur. In systematibus ubi punctum neutrum per bobinam Petersen (bobinam suppressionis arcus) ad terram connectitur, lucerna indicativa „Bobina Petersen Operatur“ etiam accenditur.Indicationes Voltmetri Monitoris Isolationis:Tensio phase
    01/30/2026
  • Modus operationis terre iunctae puncti neutralis pro transformatoribus retis electricitatis 110kV~220kV
    Dispositio modi operis terrae puncti neutralis pro transformatoribus rete electricitatis 110kV~220kV debet exigentias tolerationis insulationis puncti neutralis transformatorum complere, et simul conari ut impedimentum sequentiae nullae stationum transformationis fere immutatum maneat, dum certatur ne impedimentum sequentiae nullae compositum in quocumque puncto raptus circuiti systematis ultra ter impedimentum sequentiae positivae compositum excedat.Pro transformatoribus 220kV et 110kV in novis
    01/29/2026
  • Cur Quare Substationes Lapidem Gravem Calculos et Rupem Fractam Utuntur
    Cur Quare Substationes Utuntur Lapidibus, Gravibus, Piscinis et Saxis Tritis?In stationibus transformationis, instrumenta ut transformatores electricitatis et distributionis, lineae transmissionis, transformatores tensionis, transformatores currentis et commutatores disiunctionis omnia terram exigunt. Praeter terram, nunc profundius explorabimus cur gravia et saxa trita in stationibus transformationis saepe utuntur. Quamquam videantur ordinaria, isti lapides partem criticam iuxtaque functionalem
    01/29/2026
  • Cur autem nucleus transformatoris tantum in uno puncto terram tangere debet Nonne terra multipuncta fidelius est
    Cur ergo nucleus transformatoris terram tangere debet?In operatione, nucleus transformatoris, simul cum structuris, partibus et componentibus metallicis quae fixant nucleum et spiras, in forti campo electrico situs est. Sub influentia huius campi electrici, potentialem relativum altum ad terram comparatum acquirunt. Si nucleus non terra tangitur, differentia potentialis inter nucleum et structuras claudicantes et vas terratum existet, quae possit ad intermitterentiam dismissionem ducere.Praetere
    01/29/2026
  • Intellegere Terram Neutralis Transformatoris
    I. Quid est Punctum Neutrum?In transformatoribus et generatoribus, punctum neutrum est locus specificus in spira ubi absoluta tensio inter hunc locum et singula terminalia externa aequalis est. In diagrammate infra, punctumOrepraesentat punctum neutrum.II. Cur Punctum Neutrum Terrendum Est?Modus connexionis electricae inter punctum neutrum et terram in systemate AC triphasico diciturmodus terrendi puncti neutri. Hic modus directe afficit:Securitatem, fidem et oeconomiciam retelectrici;Selectione
    01/29/2026
Non invenisti adhuc opportunos fornitoris ut te inveniant Citationem Nunc Accipe
Non invenisti adhuc opportunos fornitoris ut te inveniant
Citationem Nunc Accipe
Inquiry
+86
Click to upload file
Descarica
Obtine Applicatio Commerciale IEE-Business
Utiliza app IEE-Business ad inveniendum apparatus obtinendumque solutiones coniungendum cum peritis et participandum in collaboratione industriale ubique et semper propter totam supportionem tuorum projectorum electricitatis et negotiorum