alataline on-line UPS elektritoe (3-faasiline sisend 1-faasiline väljund)

  • low frequency on-line UPs power supply (3phase input 1phase output)

Olulised atribuudid

Bränd Switchgear parts
Mudeli number alataline on-line UPS elektritoe (3-faasiline sisend 1-faasiline väljund)
Nominaalsagedus 50/60Hz
Väljundvool 405VDC/220VDC
Sisendpinge 380V
Võimekusega 10kVA
Seeriad HBD

Tarnijalt saadud tootekirjeldused

Kirjeldus

Toote omadused

Targem digitaalne juhtimistehnoloogia
Kasutab Intel kiirtoonikuid ja programmeeritavaid loogikaseadmeid, et saavutada toiteahela juhtimine, parameetrite seadistamine, töö haldamine, täiustatud eneseanalüüs ja enesekontrolli funktsioonid. See suudab teha eneseanalüüsi ja veapuude analüüsi kõigil sõltumatutel toiteahela ühendustel. Võite täielikult usaldada digitaalselt teisendatud siinuslaine pinge peale ning uue lahenduse täiuslikuks tööks, et vastata teie tegelikele vajadustele.
Tõhus IGBT (Insulateeritud väravaga bipolartransistor) inversoritehnoloogia
IGBT-l on suurepärase kiirusega lülitusomadused; Omab kõrge pinge ja kõrge vooluga töötamise omadusi; Kasutab pingetüüpi juhtimist, nõudes ainult väikest juhtimisvõimsust. Kuues põlvkond IGBT-d on madalama küllastuslangusega, kõrgema inversori tõhususega ja kõrgema usaldusväärsusega.
Erakordne koormusomadused
Võimaldab täielikult rahuldada koormuse muutumist 0–100% piirkonnas ilma üleminekuta mööditraassile, tagades stabiilse ja usaldusväärse väljundi.
Inimkeskne suure ekraaniga LCD-näidik nii hiina kui ka inglise keeles
Suur ekraan kuvab menüüd nii hiina kui ka inglise keeles, selge vooludiagramm näitab tööolekut, võimaldades paindlikku inimese-masin dialoogi. Intuitiivsed LED-olekunäidikud, töövoostilised olekunäidikud – kõik selgelt ülevaatlik.
Kõrge jõudlusega dünaamilised omadused
Rakendatakse mitmeid tagasiside kontrollimeetodeid, sealhulgas hetk-kontrolli ja efektiivväärtuse kontrolli, et saavutada kõrge dünaamiline reguleerimine ja vähendada väljundpinge moonutusi.
Täielik kaitsefunktsioon
Mitmetugeste süsteemikaitsed ja hoiatusfunktsioonid, sealhulgas sisendi/väljundi ülepinge kaitse, sisendlülitusimpulsi kaitse, faasijärjekorra kaitse, aku madala pinge kaitse, väljundi ülepinge kaitse ja kõrge temperatuuri kaitse.
Targem aku haldamine
Targem aku laadimine: Reguleerib automaatselt aku laadimisparameetreid vastavalt kasutaja aku konfiguratsioonile ning teeb tasakaalustatud ja ujumislaadimise ülemineku, temperatuurikompensoeritud laadimise ja tühjenduse halduse vastavalt toiteallikate keskkonnale. Pikendab aku eluiga ja vähendab haldajate koormust.
Kasutatakse 6-pulsilist (valikuliselt 12-pulsiline) alalisvooluks muundurit koos sisendharmonilise filtriga
Tõhusalt vähendab sisendharmonilist saastumist, parandab UPS-toiteallika sisendvõimsustegurit ja vähendab sisendharmonilist voolu.
Targem jälgimine
RS232 ja RS485 sideportsid võimaldavad tõepoolest mitmekülgset sidet ja kaugjälgimist. Valikuline SNMP-kaart kaugjälgimiseks ja võrguhalduseks; valikuline kuivkontaktliides, kasutades passiivseid kontakte UPS-i oleku jälgimiseks.

Rakendusalad
Sobib finants-, side-, börsi-, maksu-, transpordi-, kindlustus-, riigi-, hoonevalgustuse, teede valgustuse, elektrienergia ning tööstus- ja kaevandusettevõtete valdkonda.

Tehnilised andmed

Model HBD-6KS HBD-10KS HBD-15KS HBD-20KS HBD-30KS HBD-40KS HBD-50KS HBD-60KS HBD-80KS
Nominal Capacity 6KVA 10KVA 15KVA 20KVA 30KVA 40KVA 50KVA 60KVA 80KVA
Working Mode and Principle Online Power Supply, Static Bypass Switch (No-break Switching), Double Conversion Technology Online Power Supply, Static Bypass Switch (No-break Switching), Double Conversion Technology Online Power Supply, Static Bypass Switch (No-break Switching), Double Conversion Technology Online Power Supply, Static Bypass Switch (No-break Switching), Double Conversion Technology Online Power Supply, Static Bypass Switch (No-break Switching), Double Conversion Technology Online Power Supply, Static Bypass Switch (No-break Switching), Double Conversion Technology Online Power Supply, Static Bypass Switch (No-break Switching), Double Conversion Technology Online Power Supply, Static Bypass Switch (No-break Switching), Double Conversion Technology Online Power Supply, Static Bypass Switch (No-break Switching), Double Conversion Technology
AC Input                  
Phase Number Three Phase (A, B, C+N+G) Three Phase (A, B, C+N+G) Three Phase (A, B, C+N+G) Three Phase (A, B, C+N+G) Three Phase (A, B, C+N+G) Three Phase (A, B, C+N+G) Three Phase (A, B, C+N+G) Three Phase (A, B, C+N+G) Three Phase (A, B, C+N+G)
Input Nominal Voltage 380 VAC 380 VAC 380 VAC 380 VAC 380 VAC 380 VAC 380 VAC 380 VAC 380 VAC
Input Voltage Range ± 25% ± 25% ± 25% ± 25% ± 25% ± 25% ± 25% ± 25% ± 25%
Nominal Frequency 50Hz ± 10%, 60Hz ± 10% 50Hz ± 10%, 60Hz ± 10% 50Hz ± 10%, 60Hz ± 10% 50Hz ± 10%, 60Hz ± 10% 50Hz ± 10%, 60Hz ± 10% 50Hz ± 10%, 60Hz ± 10% 50Hz ± 10%, 60Hz ± 10% 50Hz ± 10%, 60Hz ± 10% 50Hz ± 10%, 60Hz ± 10%
Voltage Harmonic Distortion <5% <5% <5% <5% <5% <5% <5% <5% <5%
Soft Start 0~100% 5sec 0~100% 5sec 0~100% 5sec 0~100% 5sec 0~100% 5sec 0~100% 5sec 0~100% 5sec 0~100% 5sec 0~100% 5sec
Battery (Maintenance-free Lead-acid Battery)                  
Nominal Voltage 360VDC/192VDC 360VDC/192VDC 360VDC/192VDC 360VDC/192VDC 360VDC/192VDC 360VDC/192VDC 360VDC/192VDC 360VDC/192VDC 360VDC/192VDC
Quantity Unit 30 cells/12V in series (16 cells/12V in series) 30 cells/12V in series (16 cells/12V in series) 30 cells/12V in series (16 cells/12V in series) 30 cells/12V in series (16 cells/12V in series) 30 cells/12V in series (16 cells/12V in series) 30 cells/12V in series (16 cells/12V in series) 30 cells/12V in series (16 cells/12V in series) 30 cells/12V in series (16 cells/12V in series) 30 cells/12V in series (16 cells/12V in series)
Charging                  
Maximum Output Voltage 405VDC/220VDC 405VDC/220VDC 405VDC/220VDC 405VDC/220VDC 405VDC/220VDC 405VDC/220VDC 405VDC/220VDC 405VDC/220VDC 405VDC/220VDC
Float Voltage 405VDC/220VDC (Automatic Battery Equalization Once Every 3 Months, Charging Voltage 435VDC/232VDC) 405VDC/220VDC (Automatic Battery Equalization Once Every 3 Months, Charging Voltage 435VDC/232VDC) 405VDC/220VDC (Automatic Battery Equalization Once Every 3 Months, Charging Voltage 435VDC/232VDC) 405VDC/220VDC (Automatic Battery Equalization Once Every 3 Months, Charging Voltage 435VDC/232VDC) 405VDC/220VDC (Automatic Battery Equalization Once Every 3 Months, Charging Voltage 435VDC/232VDC) 405VDC/220VDC (Automatic Battery Equalization Once Every 3 Months, Charging Voltage 435VDC/232VDC) 405VDC/220VDC (Automatic Battery Equalization Once Every 3 Months, Charging Voltage 435VDC/232VDC) 405VDC/220VDC (Automatic Battery Equalization Once Every 3 Months, Charging Voltage 435VDC/232VDC) 405VDC/220VDC (Automatic Battery Equalization Once Every 3 Months, Charging Voltage 435VDC/232VDC)
Microcomputer-set Charging Current 1A~50A (Automatically Adjusted to 0.1C According to Battery Capacity) 1A~50A (Automatically Adjusted to 0.1C According to Battery Capacity) 1A~50A (Automatically Adjusted to 0.1C According to Battery Capacity) 1A~50A (Automatically Adjusted to 0.1C According to Battery Capacity) 1A~50A (Automatically Adjusted to 0.1C According to Battery Capacity) 1A~50A (Automatically Adjusted to 0.1C According to Battery Capacity) 1A~50A (Automatically Adjusted to 0.1C According to Battery Capacity) 1A~50A (Automatically Adjusted to 0.1C According to Battery Capacity) 1A~50A (Automatically Adjusted to 0.1C According to Battery Capacity)
AC Output                  
Rated Power (KW COSφ=0.8) Nominal Power × 0.8 Nominal Power × 0.8 Nominal Power × 0.8 Nominal Power × 0.8 Nominal Power × 0.8 Nominal Power × 0.8 Nominal Power × 0.8 Nominal Power × 0.8 Nominal Power × 0.8
Phase Number Single Phase (L+N+G) Single Phase (L+N+G) Single Phase (L+N+G) Single Phase (L+N+G) Single Phase (L+N+G) Single Phase (L+N+G) Single Phase (L+N+G) Single Phase (L+N+G) Single Phase (L+N+G)
Nominal Phase Voltage 220VAC ± 1% (Stable Load), 220VAC ± 5% (Load Fluctuation) 220VAC ± 1% (Stable Load), 220VAC ± 5% (Load Fluctuation) 220VAC ± 1% (Stable Load), 220VAC ± 5% (Load Fluctuation) 220VAC ± 1% (Stable Load), 220VAC ± 5% (Load Fluctuation) 220VAC ± 1% (Stable Load), 220VAC ± 5% (Load Fluctuation) 220VAC ± 1% (Stable Load), 220VAC ± 5% (Load Fluctuation) 220VAC ± 1% (Stable Load), 220VAC ± 5% (Load Fluctuation) 220VAC ± 1% (Stable Load), 220VAC ± 5% (Load Fluctuation) 220VAC ± 1% (Stable Load), 220VAC ± 5% (Load Fluctuation)
Nominal Frequency 50Hz ± 0.1% (Battery Power Supply) 50Hz ± 0.1% (Battery Power Supply) 50Hz ± 0.1% (Battery Power Supply) 50Hz ± 0.1% (Battery Power Supply) 50Hz ± 0.1% (Battery Power Supply) 50Hz ± 0.1% (Battery Power Supply) 50Hz ± 0.1% (Battery Power Supply) 50Hz ± 0.1% (Battery Power Supply) 50Hz ± 0.1% (Battery Power Supply)
Frequency Stability: Asynchronous < ± 0.1% < ± 0.1% < ± 0.1% < ± 0.1% < ± 0.1% < ± 0.1% < ± 0.1% < ± 0.1% < ± 0.1%
Frequency Stability: Synchronous < ± 5% < ± 5% < ± 5% < ± 5% < ± 5% < ± 5% < ± 5% < ± 5% < ± 5%
Crest Factor 3: 1 3: 1 3: 1 3: 1 3: 1 3: 1 3: 1 3: 1 3: 1
Output Waveform Sine Wave Sine Wave Sine Wave Sine Wave Sine Wave Sine Wave Sine Wave Sine Wave Sine Wave
Total Harmonic Distortion Linear Load < 3%; Non-linear Load < 5% Linear Load < 3%; Non-linear Load < 5% Linear Load < 3%; Non-linear Load < 5% Linear Load < 3%; Non-linear Load < 5% Linear Load < 3%; Non-linear Load < 5% Linear Load < 3%; Non-linear Load < 5% Linear Load < 3%; Non-linear Load < 5% Linear Load < 3%; Non-linear Load < 5% Linear Load < 3%; Non-linear Load < 5%
Operating Temperature 0~40℃ 0~40℃ 0~40℃ 0~40℃ 0~40℃ 0~40℃ 0~40℃ 0~40℃ 0~40℃
Relative Humidity 30%~90% (No Condensation) 30%~90% (No Condensation) 30%~90% (No Condensation) 30%~90% (No Condensation) 30%~90% (No Condensation) 30%~90% (No Condensation) 30%~90% (No Condensation) 30%~90% (No Condensation) 30%~90% (No Condensation)
Operating Altitude < 1000 meters (Power Drops by 1% for Every 100 Meters Increase, Maximum 3000 Meters) < 1000 meters (Power Drops by 1% for Every 100 Meters Increase, Maximum 3000 Meters) < 1000 meters (Power Drops by 1% for Every 100 Meters Increase, Maximum 3000 Meters) < 1000 meters (Power Drops by 1% for Every 100 Meters Increase, Maximum 3000 Meters) < 1000 meters (Power Drops by 1% for Every 100 Meters Increase, Maximum 3000 Meters) < 1000 meters (Power Drops by 1% for Every 100 Meters Increase, Maximum 3000 Meters) < 1000 meters (Power Drops by 1% for Every 100 Meters Increase, Maximum 3000 Meters) < 1000 meters (Power Drops by 1% for Every 100 Meters Increase, Maximum 3000 Meters) < 1000 meters (Power Drops by 1% for Every 100 Meters Increase, Maximum 3000 Meters)
Options RS485 Network Adapter (SNMP) / Cabinet Size Can Be Designed According to Requirements RS485 Network Adapter (SNMP) / Cabinet Size Can Be Designed According to Requirements RS485 Network Adapter (SNMP) / Cabinet Size Can Be Designed According to Requirements RS485 Network Adapter (SNMP) / Cabinet Size Can Be Designed According to Requirements RS485 Network Adapter (SNMP) / Cabinet Size Can Be Designed According to Requirements RS485 Network Adapter (SNMP) / Cabinet Size Can Be Designed According to Requirements RS485 Network Adapter (SNMP) / Cabinet Size Can Be Designed According to Requirements RS485 Network Adapter (SNMP) / Cabinet Size Can Be Designed According to Requirements RS485 Network Adapter (SNMP) / Cabinet Size Can Be Designed According to Requirements
Dimensions (W×D×H) mm 390×659×860 430×760×1350 710×720×1450 710×850×1500 - - - 1100×860×1680 -
Main Unit Weight 150 199 220 305 380 480 566 590 986

Märkus: Mudel, mis sisaldab sisseehitatud aku ja erilisi pingevõtteid, saab kohandada kasutaja tegeliku olukorra järgi ning eraldi makseta pakkumine antakse.

FAQ
Q: Kuidas lahendada selle UPS-i tavalisi vigu?
A:

① Ülekoormise alarm: ühendage mitteolulised ühefaasilised laadid, või asendage suurema võimsusega UPS; ② Faasi kadumise alarm: kontrollige 3-faasilist sissetulevat juhtmeet ja parandage laske või lahkuvad kaabelid; ③ Aku nõrga aja alarm: laetage pidevalt 12 tundi, asendage vananenud akud, kui alarm jätkub; ④ Väljundvoolu ebatõene: kontrollige väljundjuhtmeid, lülitage UPS uuesti sisse (ühenduseta jääge 5 minutit); ⑤ Trafotööriüleseis: peatage kohe kasutamine, kontrollige ventilatsiooni ja laadi, pöörduge pärastmüügi poole hoolduseks.

Q: Mis on 3-faasise sisendiga 1-faasine väljundiga madala sagedusega võrgus ühendatud reserveeritud jõuvoo (on-line UPS) põhifunktsioon ja tööprintsiip
A:

Tundke oma tarnija

Veebipood
Ajakohane tarne tase
Vastusaja
100.0%
≤4h
Ettevõtte ülevaade
Töökohvik: 1000m² Töötajate arv: Suurim aastane eksport (USA dollari): 300000000
Töökohvik: 1000m²
Töötajate arv:
Suurim aastane eksport (USA dollari): 300000000
Teenused
Äripädevus: Müük
Peamised kategooriad: Seadme lisavarustus/Seadmed kontrollimiseks/Kõrgepinge seadmed/Väikesevooliline elektriseadmeid/Mõõturid ja mõõteseadmed/Tootevahendid/Elektritööriistad
Kogu eluea hooldus haldur
Whole-life care management teenused seadmete hankimiseks, kasutamiseks, hoolduseks ja müügi järelhoolduseks, tagades elektriseadmete ohutu töö, pideva kontrolli ja murevaba elektritarbimise
Varustustarnija on läbinud platvormi kvalifikatsioonikinnituse ja tehnilise hinnangu, tagades nõuetele vastavuse, professionaalsuse ja usaldusväärsuse algallikast

Seotud tooted

Seotud teadmised

  • DC-ihoone mõju transformatorites taasenergiajaamades lähedal UHVDC maandumiselektroodidele
    DC-põhja mõju transformatorkes ülevooluliste energiajaamade lähedal UHVDC-maanduselustite lähedusesKui ülevoolulise energiaga (UHVDC) edastussüsteemi maanduselust on asetatud lähedal taastuvenergia elektrijaama, võib maapinnal liikuv tagasisidevool põhjustada maapotentsiaali tõusu elustiku ümbruses. See maapotentsiaali tõus viib lähedate kõrgpinge transformatorite neutraalpunkti potentsiaali muutusele, mille tulemusena tekib nende tuumades DC-põhi (või DC-nihke). Selline DC-põhi saab vähendada t
    01/15/2026
  • HECI GCB for Generators – Kiiruslik SF₆ lülitik
    1.Definitsioon ja funktsioon1.1 Tootja ühendussulga rollTootja ühendussulg (GCB) on kontrollitav lahkuva punkt tootja ja tõstmustransformatori vahel, mille kaudu tootja suhtub elektrivõrguga. Selle peamised funktsioonid hõlmavad tootja poolel asuvate vigade eraldamist ja tootja sünkroniseerimisel ning võrguühenduse loomisel operatiivset kontrolli. GCB töötamise printsiip ei ole oluliselt erinev tavalisest ühendussulgast; kuid tootja vigadevoogude kõrge DC komponendi tõttu on GCB-delt nõutud äärm
    01/06/2026
  • Jaamistusseadmete transformaatorite testimine kontrollimine ja hooldus
    1. Transformaatori hooldus ja kontroll Lülitage välja hooldatava transformaatori madalpinge (LV) lüliti, eemaldage juhtimisvoolu sulav, ja riputage lülitikäepidemele hoiatussilt „Ära sulge”. Lülitage välja hooldatava transformaatori kõrgepinge (HV) lüliti, sulgege maanduslüliti, laadige transformaator täielikult tühjaks, lukustage kõrgepinge paneel ja riputage lülitikäepidemele hoiatussilt „Ära sulge”. Kuivtüüpi transformaatori hoolduse puhul: puhastage esmalt porcelaanisolatsioonid ja kaitsekar
    12/25/2025
  • Kuidas testimine jaoturi transformaatorite izoleerimispinge
    Praktilises töös mõõdetakse jaotustransformaatorite isolatsioonitakistust tavaliselt kaks korda: isolatsioonitakistuskõrgepinge (HV) mähisejamahapoolepinge (LV) mähise pluss transformaatori paagi vahel ning isolatsioonitakistusLV mähisejaHV mähise pluss transformaatori paagi vahel.Kui mõlemad mõõtmised annavad vastuvõetavad tulemused, näitab see, et HV-mähise, LV-mähise ja transformaatori paagi vaheline isoleerimine on sobiv. Kui ükski mõõtmine ebaõnnestub, tuleb kõigi kolme komponendi (HV–LV, H
    12/25/2025
  • Põhivõrgu püsiülejooksvate transformaatorite disainiprincipid
    Põhivoolujooneliste jaotustransformatorite disainiprinsipid(1) Asukoha ja paigutuse põhimõttedPõhivoolujoonelise transformatori platvorm tuleb asetada lähedal laadikeskusele või kriitilistele laadidele, järgides "väikese kapatsiteediga, mitmeid asukohti" printsiipi, et lihtsustada seadmete vahetamist ja hooldust. Elamurajooni varustamiseks võib lähedale paigutada kolmefaseilisi transformatoreid, arvestades praegust nõudlust ja tuleviku kasvu prognoose.(2) Kolmefaseiliste põhivoolujooneliste tran
    12/25/2025
  • Transformaatorimüra kontrollimise lahendused erinevate paigaldustele
    1.Müra Vähendamine Maapinnal Asuvatele Sõltumatutele TransformatorkambrileVähendamise Strategia:Esiteks, läbi viiakse voolu väljalülituse ja transformatori hooldus, mis hõlmab vananenud eraldusõli asendamist, kõigi kinnitiste kontrollimist ja karmistamist ning ühiku pööri eemaldamist.Teiseks, tugevdatakse transformatori alust või installitakse vibratsioonideeriv seadmeid – näiteks kummipattude või keelede isolatoore – valik teostatakse sõltuvalt vibratsioonide tõsidusest.Lõpuks, tugevdatakse hel
    12/25/2025
Väljastatud tarnijad leiavad sind Saada pakkumine kohe
Väljastatud tarnijad leiavad sind
Saada pakkumine kohe
Saada hinnapäring
+86
Klõpsa faili üleslaadimiseks

IEE Business will not sell or share your personal information.

Allalaadimine
IEE Businessi rakenduse hankimine
IEE-Business rakendusega leidke varustus saada lahendusi ühenduge ekspertidega ja osalege tööstuslikus koostöös kogu aeg kõikjal täielikult toetades teie elektritööde ja äri arengut