• KW-1 Series simulation rain - shower tester
KW-1 Series simulation rain - shower tester
discuss personally
Model
KW-1
Basic info
Brand Wone Store
Model NO. KW-1 Series simulation rain - shower tester
Rated voltage 220V
Series KW-1 Series
Product Detail

Overview

  • With the rapid development of modern industrial technology, the application fields of electrical and electronic products are becoming increasingly wide, and the environmental conditions they endure are becoming more and more complex and diverse. Only by reasonably specifying the environmental conditions of products and correctly selecting the environmental protection measures for products can we ensure that the products are free from damage during storage and transportation and are safe and reliable during the use process. Therefore, conducting artificial simulation environmental tests on electrical and electronic products is an essential and important link to ensure their high quality. Artificial simulation environmental tests are a scientific generalization of the impact of the actual environment, with characteristics such as typification, standardization, convenience of use, and ease of comparison. The diversification of environmental conditions and the importance of environmental tests also pose more stringent requirements for environmental test equipment.

  • The damage caused by natural rainwater to products and materials incurs incalculable economic losses every year. The damages mainly include corrosion, fading, deformation, strength reduction, swelling, mildew, etc. Especially, electrical products are prone to short - circuits due to rainwater, which can easily lead to fires. Therefore, it is an essential and crucial procedure to conduct the enclosure protection water test for specific products or materials. This set of waterproof test equipment can be used to assess and determine whether the enclosures and seals of electrical and electronic products and automotive parts can ensure the good working performance of the equipment and components after or during the water test. The equipment can fully simulate the external rain - shower environment and fully reproduce the impact of the external rain - shower environment on products.

  • This equipment conducts artificial simulation rain - shower tests, excluding rainfall with strong wind speeds, and does not consider the large - scale water inflow caused by the temperature difference between the test sample and the rainwater temperature.

  • This equipment can provide corresponding environmental simulation and acceleration tests for scientific research, product development, and quality control. The performance indicators of the equipment all meet the requirements specified in national standards GB/T 4208 - 2008, GB/T 4942 - 93, and GB/T 2423.38.

Application environment

  • For the convenience of ventilation, operation, and maintenance, a certain space should be left between the equipment and adjacent items or walls to facilitate the operation of workers. There should be a space of not less than 1 - 1.5 meters in front of, behind, to the left, and to the right of the cabinet.

  • It should be installed in a place without direct sunlight.

  • It should be installed away from combustibles, explosives, and high - temperature heat sources.

  • Install it as close as possible to the power supply.

  • It is best to install the equipment in an independent room to avoid damage to other equipment that may be caused by excessive moisture during the operation.

  • The workroom should be equipped with ventilation facilities to allow for ventilation at any time.

  • The workroom should have an AC220V power supply.

  • To stabilize the performance and functions of the equipment, it should be in a working environment with an annual temperature of 15°C - 28°C and a relative humidity not higher than 85%.

  • Sharp changes in the ambient temperature and humidity of the installation site are strictly prohibited.

  • It should be installed on a level ground.

  • After the equipment is installed, sunlight should not directly shine on the surface of the equipment.

Know your supplier
Wone Store
Main Categories
High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment/Instrument Transformer/Equipment Parts
Business Type
Sales
Highest Annual Export (USD)
$300000000
Professional Experience
1 years
Workplace
1000m²
占位
占位
Related Products
Related Knowledges
What safety protection facilities are there in the transformer body structure?
What safety protection facilities are there in the transformer body structure?
Transformer Main Body Construction and Safety Protection DevicesA power transformer is equipped with several critical safety protection devices to ensure reliable and safe operation. These components play essential roles in monitoring, protecting, and maintaining the integrity of the transformer under varying operating conditions.1. Oil Cushion (Conservator Tank)The oil cushion, also known as the conservator tank, typically has a capacity of approximately 8–10% of the total transformer oil
Rockwell
08/09/2025
Analysis on Live Testing of 10kV SF₆ Ring Main Units
Analysis on Live Testing of 10kV SF₆ Ring Main Units
1 Live Testing AnalysisDetection of Issues through Live TestingIn October of a certain year, during live partial discharge (PD) testing on 10kV ring main units (RMUs) under our jurisdiction, the maintenance and testing team observed significantly elevated signal amplitudes in several units (Transient Earth Voltage (TEV) readings around 18 dB, and ultrasonic readings around 20 dB). Most of these units were from the same manufacturer. Consequently, a unified test was conducted on 15 RMUs from this
Oliver Watts
08/09/2025
Analysis of Two Faults in 10kV SF6 Ring Main Units
Analysis of Two Faults in 10kV SF6 Ring Main Units
1. Introduction to 10kV SF6 Ring Main Units (RMUs)A 10kV SF6 ring main unit typically consists of three main parts: the gas compartment (tank), the operating mechanism compartment, and the cable connection compartment.The gas compartment is the core component of the RMU. It is filled with SF6 gas and houses critical elements such as the load switch, busbars, and switch shaft. The load switch features a three-position design—comprising closing, opening, and grounding functions—and is
Felix Spark
08/09/2025
A Brief Analysis of Technical Issues in SF6 Fully Insulated Gas-Insulated Ring Main Units
A Brief Analysis of Technical Issues in SF6 Fully Insulated Gas-Insulated Ring Main Units
SF6 Fully Insulated Gas-Insulated Ring Main Units (hereinafter referred to as RMUs) primarily consist of load switch units and high-voltage AC load switch-fuse combination appliances (hereinafter referred to as combination appliances). Depending on user requirements, they can be configured as either common-tank or unitized structures.In practical engineering applications, electrical connections are typically established using either top-mounted solid-insulated busbars or side-mounted plug-in bus
Ron
08/09/2025
Advantages of SF6 Fully Insulated Ring Main Units in Power Supply Systems
Advantages of SF6 Fully Insulated Ring Main Units in Power Supply Systems
Current Power Supply Method Using SF6 Ring Main UnitsTo enhance grid performance, the design of traditional SF6 ring main units (RMUs) has been further optimized. A key feature of second-generation SF6 RMUs is the use of a grounded, enclosed epoxy resin housing, with SF6 gas as the insulating medium. Two three-position load switches and one three-position arc-rotating circuit breaker are integrated into a single sealed unit, equipped with a pressure relief safety valve. In the event of arc-quenc
Echo
08/09/2025
What types of transformer voltage regulation are there?
What types of transformer voltage regulation are there?
Transformer voltage regulation can be achieved through on-load tap changing (OLTC) and off-load tap changing:On-load voltage regulation allows the transformer to adjust its tap position while in operation, thereby changing the turns ratio to regulate voltage. There are two methods: line-end regulation and neutral-point regulation. Line-end regulation involves placing the tap on the line end of the high-voltage winding, whereas neutral-point regulation places the tap on the neutral end of the hig
Vziman
08/09/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!