• JDZX16-12R voltage transformer
JDZX16-12R voltage transformer
discuss personally
Model
JDZX16-12R
Basic info
Brand Wone Store
Model NO. JDZX16-12R voltage transformer
Rated frequency 50/60Hz
Primary voltage 22/√3kV
Secondary voltage 110/√3V
Series JDZX
Product Detail

Product Overview

JDZX16-12R voltage transformer, epoxy resin casting and full enclosed construction, is used indoor switch cabinet to measure the current, electric energy and protective relaying in single phase or three phase AC circuit with the frequency 50Hz or 60Hz and highest voltage for equipment 17.5/24 kV.

The iron core adopts advanced cold-rolled silicon steel sheet. High voltage outgoing line of primary winding was fetched out from top of the product; outgoing line of secondary winding was fetched out from transverse side of the product.

Key Features

  • Anti-Fouling Flashover & High Insulation Performance:With external insulation creepage distance ≥31mm/kV, equipped with anti-fouling flashover skirts and hydrophobic coatings, suitable for Class Ⅲ pollution areas. Partial discharge ≤5pC, passing 12kV/42kV/75kV power frequency/impulse withstand voltage tests, effectively reducing the risk of fouling flashover and ensuring long-term reliable operation in harsh environments.
  • Compact Design & Flexible Installation:Volume reduced by 40% compared to traditional oil-immersed transformers, weighing only 80kg, supporting vertical or horizontal installation. Compatible with mainstream medium-voltage switchgear like KYN28 and XGN15, simplifying substation layout and saving space costs.
  • Intelligent Monitoring Interface:Optional Modbus RTU digital output module for real-time voltage data transmission to monitoring systems, supporting remote condition monitoring and fault early warning. Compatible with smart grid architecture to facilitate digital upgrading of substations.
  • International Standard Compliance:Complies with IEC 60044-2 and GB/T 1207-2022 standards, certified by CE and RoHS. Insulation system meets UL94 V-0 flame retardant grade, with internationally recognized product quality and safety, suitable for domestic and foreign power engineering projects.

Technical parameter

  • Rated primary voltage: 20/√3 or 15/√3etc.
  • Technical standard accords with IEC 60044-2:2003 Part2 Instrument transformers-Part2: inductive voltage transformers

Remarks: Upon request we are glad to offer transformers according to other standards or with non-standard technical specs.

Know your supplier
Wone Store
Main Categories
High voltage/Low voltage/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment/MV & LV CT PT/Equipment Parts
Business Type
Sales
Highest Annual Export (USD)
$300000000
Professional Experience
1 years
Workplace
1000m²
占位
占位
Related Products
Related Knowledges
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
Low-voltage current transformers, as indispensable measurement and protection devices in power systems, often encounter various faults when used in combination with other power equipment due to environmental factors, equipment linkage issues, and improper installation and maintenance. These faults not only affect the normal operation of power equipment but may also endanger personal safety. Therefore, it is necessary to gain an in-depth understanding of fault types, judgment methods, and prevent
Felix Spark
07/17/2025
What are the monitoring methods and future development trends of low-voltage voltage transformers?
What are the monitoring methods and future development trends of low-voltage voltage transformers?
With the continuous advancement of smart grid technology, intelligent monitoring systems are playing an increasingly important role in preventing and addressing faults in voltage transformers. These modern intelligent monitoring systems can collect key parameters from voltage transformers in real time—such as partial discharge levels, temperature, and oil quality—and use data analysis algorithms to assess the health status of the equipment, enabling early fault warnings and precise l
Echo
07/16/2025
What are the common faults of low-voltage voltage transformers?
What are the common faults of low-voltage voltage transformers?
1. Open - Circuit Fault on the Secondary SideOpen - circuit in the secondary side is a typical fault of low - voltage voltage transformers, showing abnormal voltmeter readings (zero/fluctuation), faulty power meters, buzzing noises, and core overheating. When open - circuited, the secondary voltage spikes (no secondary current to balance the primary EMF), causing core saturation, flux distortion, and potential overheating/damage.Causes include loose terminals, poor contact, or human error. In lo
Oliver Watts
07/16/2025
A Quick Verification Method for Low-Voltage Current Transformers
A Quick Verification Method for Low-Voltage Current Transformers
1. Selection of Low - Voltage Current Transformer ConfigurationThere are many factors leading to wrong selection of low - voltage current transformers in civil construction projects. For example, common factors include design problems: the calculated coefficient designed for the load of electrical equipment is relatively large, or the transformation ratio of the current transformer is selected incorrectly. Such a series of reasons will affect the use of electrical equipment. Therefore, in the co
James
07/16/2025
A Quick Verification Method for Low-Voltage Current Transformers
A Quick Verification Method for Low-Voltage Current Transformers
To ensure safe operation of the power system, power equipment operation must be monitored/measured. General devices can’t connect to primary high - voltage equipment directly; instead, large primary currents are scaled down for current transformation, electrical isolation, and use by measurement/protection devices. For AC large - current measurement, conversion to a unified current eases secondary instrument use.Current transformers split into measurement - and protection - type, with accu
Oliver Watts
07/16/2025
Research on Low - Voltage Anti - DC Current Transformer and Detection Device
Research on Low - Voltage Anti - DC Current Transformer and Detection Device
1. Overview of Components and IssuesTA (low-voltage current transformer) and electric energy meters are key components of low-voltage electric energy metering. The load current of such meters is no less than 60A. Electric energy meters vary in type, model, and anti-DC performance, and are connected in series in the metering device. Due to the lack of anti-DC capability, they suffer from metering errors under DC component loads, usually caused by non-linear loads. With the increasing use of DC or
Dyson
07/16/2025
×