| Marca | Wone Store |
| Numerus Modeli | JDZW2-36 Transformer Voltae Externus |
| Frequenta nominata | 50/60Hz |
| Tensio primitivus | 33kV |
| voltus secundarius | 110V |
| Series | JDZW |
Product Overview
JDZW2-36 voltage transformer, outdoor epoxy resin casting and double pole insulated VT, is widely used for measuring current, electric energy and protective relaying in the isolated neutral system with the frequency 50Hz or 60Hz and insulation voltage 36 kV (Up to 40.5kV).
The iron core adopts advanced cold-rolled silicon steel sheet. High voltage outgoing line of primary winding was fetched out from top of the product; outgoing line of secondary winding was fetched out from transverse side of the product.
Key Features
Totus clausus structura insulatoria: Productum hoc structuram posticam totius clausam cum strato insulatorio silicis rubri externo praebet, quae polluti et humiditatis resistit. Hoc design non solum humectationem resistentiam augeat, sed etiam performance anti-fouling flashover significanter meliorat, idoneum pro ambientibus exteriis altae pollutionis et operationem longa tempora fideliter sub conditionibus duris assecurans.
Transformatio alti praecisionis voltus: Hic transformator voltus accurate mensurat, convertens 36kV altum voltum in voltum parvum ad dispositiva mensurationis et protectionis aptum. Cum errore ratio voltus intra minimam rangem contineatur, satisfacit exigentias alti praecisionis mensurationis et protectionis, data fidelia de voltu pro stabilitate systematis electrici praebens et operationem temporalem et accuratam dispositivorum protectionis relais assecurans.
Compactus, levis & facilis installationis: Gratiarum actione processus totius clausi castigandi resinae epoxy, transformator est compactus, levis, et in quovis loco et orientamento posset installari. Solutionem convenientem installationis praebet pro locis restrictis spatii ut stationes transformationis et cistellae distributionis exteri, spatiolum et costus installationis salvando.
Electrica excellentia: Equipatus fusibili interno, transformator cito circuitum secat in casu defectus ad protectendum transformatorem voltus (PT), cum facile fusibile substitui possit. Terminales exitus secundarii metallica opercula protectiva sigillantur ne corpora aliena intrare possint, ulterius perficientia performance insulatoria electrica et securitatem augendo, et periculum defectuum ex problematibus connectionis electrica reducendo.
Main technical parameter
Voltus primarius nominatus: 30 kV vel 33 kV vel 35 kV etc.
Voltus secundarius nominatus: 100 V vel 110 V
Voltus sustinendi nominatus frequentiae: 70kV
Voltus sustinendi nominatus fulminis: 170kV
Norma technica IEC 60044-2.2003 conformatur.
Alia parametri vide infra:

Nota: Ex petitione laetamur offerre transformatores secundum alias normas vel cum speciebus technicis non standard.