• JDZW2-36 Outdoor Voltage Transformer
JDZW2-36 Outdoor Voltage Transformer
discuss personally
Model
JDZW2-36
Basic info
Brand Wone Store
Model NO. JDZW2-36 Outdoor Voltage Transformer
Rated frequency 50/60Hz
Primary voltage 33kV
Secondary voltage 110V
Series JDZW
Product Detail

Product Overview

JDZW2-36 voltage transformer, outdoor epoxy resin casting and double pole insulated VT, is widely used for measuring current, electric energy and protective relaying in the isolated neutral system with the frequency 50Hz or 60Hz and insulation voltage 36 kV (Up to 40.5kV).

The iron core adopts advanced cold-rolled silicon steel sheet. High voltage outgoing line of primary winding was fetched out from top of the product; outgoing line of secondary winding was fetched out from transverse side of the product.

Key Features

  • Fully Enclosed Insulation Structure:The product features a fully enclosed post-type structure with an outer silicone rubber insulation layer, effectively resisting pollution and moisture. This design not only enhances moisture resistance but also significantly improves anti-fouling flashover performance, making it ideal for high-pollution outdoor environments and ensuring long-term reliable operation under harsh conditions.

  • High-Precision Voltage Transformation:This voltage transformer accurately measures voltage, converting 36kV high voltage into low voltage suitable for measurement and protection devices. With voltage ratio error controlled within a minimal range, it meets high-precision metering and protection requirements, providing reliable voltage data for power system stability and ensuring timely and accurate operation of relay protection devices.

  •  Compact, Lightweight & Easy Installation:Thanks to the fully enclosed epoxy resin casting process, the transformer is compact, lightweight, and can be installed in any position and orientation. It offers a convenient installation solution for space-constrained locations such as substations and outdoor distribution boxes, saving installation space and costs.

  • Excellent Electrical Performance:Equipped with a built-in fuse, the transformer quickly cuts off the circuit during faults to protect the voltage transformer (PT), with easy fuse replacement. The secondary outlet terminals are sealed with metal protective covers to prevent foreign objects from entering, further enhancing electrical insulation performance and safety while reducing the risk of faults caused by electrical connection issues.

Main technical parameter

  • Rated primary voltage:30 kV or 33 kV or 35 kV  etc.

  • Rated secondary voltage:100 V or 110 V

  • Rated power-frequency withstand voltage: 70kV

  • Rated lightning impulse withstand voltage: 170kV

  • Technical standard accords with IEC 60044-2.2003.

Other parameters pls see as follow:

Remarks: Upon request we are glad to offer transformers according to other standards or with non-standard technical specs.

Outline drawing

Know your supplier
Wone Store
Main Categories
High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment/Instrument Transformer/Equipment Parts
Business Type
Sales
Highest Annual Export (USD)
$300000000
Professional Experience
1 years
Workplace
1000m²
占位
占位
Related Products
Related Knowledges
Analysis of Issues and Causes in Smart Meter Testing
Analysis of Issues and Causes in Smart Meter Testing
1. Issues and Cause Analysis in Smart Electricity Meter TestingDuring the verification of smart electricity meters, inspections must be conducted on the meter’s appearance, as well as the clarity and integrity of nameplate markings. Additionally, careful checks are required for physical damage and whether the display can show digits completely. A power-on inspection is also necessary. If error codes appear on the display after power-up, faults should be identified and addressed according to the
Oliver Watts
09/01/2025
Analysis of Common Operational Fault Causes in Smart Electricity Meters
Analysis of Common Operational Fault Causes in Smart Electricity Meters
With the continuous development of smart grids, smart electricity meters are being increasingly widely applied, and various types of operational faults in smart meters are frequently encountered in energy measurement work. This paper analyzes the causes of smart meter failures and proposes corresponding solutions, using several actual operational fault cases as examples.1. Black ScreenA black screen refers to a powered meter with no display, which is the most commonly occurring fault in field-op
Felix Spark
09/01/2025
What tests are required for a qualified smart electricity meter?
What tests are required for a qualified smart electricity meter?
In today's world, not wearing a watch is no longer unusual, but not having an electricity meter is a serious issue. As a measuring instrument vital to people's daily lives, the electricity meter is an essential tool for power consumption measurement and billing in every household. According to current national strategic requirements for smart grid development, smart electricity meters have been widely applied and promoted, bringing entirely new and extensive market opportunities to the metering
Oliver Watts
09/01/2025
Discussion on Fault Diagnosis and Handling Technologies for Smart Meters in Electricity Inspections
Discussion on Fault Diagnosis and Handling Technologies for Smart Meters in Electricity Inspections
1 Analysis of Smart Meter Faults and Their Impact on the Power Grid1.1 Introduction to Smart Meter Functions and Their Critical Role in Modern Power GridsSmart meters exchange data in real time with power companies through two-way communication, enabling functions such as remote meter reading and dynamic tariff adjustment. This capability allows users to adjust their consumption based on real-time pricing, achieving energy savings and cost reduction. Meanwhile, smart meters support grid automati
Felix Spark
09/01/2025
Analysis of the Integrated Application of Smart Meters and Meter Reading, Verification, and Billing Information Systems
Analysis of the Integrated Application of Smart Meters and Meter Reading, Verification, and Billing Information Systems
Meter reading, verification, and billing are critical operations for power companies, and their efficiency directly impacts the company's sustainable development. In recent years, with the widespread adoption of intelligent technologies, smart meters have been promoted and applied in power companies, driving transformation in meter reading and billing operations. The integrated application of smart meters and meter reading, verification, and billing information systems has become a key developme
Echo
09/01/2025
What is the difference between a dielectric and an insulator?
What is the difference between a dielectric and an insulator?
Dielectrics and insulators are distinguished primarily by their applications. One of the main differences is that a dielectric can store electrical energy by becoming polarized in an electric field, whereas an insulator resists the flow of electrons to prevent current conduction. Other key differences between them are outlined in the comparison chart below.Definition of DielectricA dielectric material is a type of insulator that contains few or no free electrons. When subjected to an electric fi
Edwiin
08/30/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!