| Marca | POWERTECH |
| Numerus Modeli | Reactores Shunt Nucleo Ferroso |
| Votum nominatum | 35kV |
| Frequenta nominata | 50/60Hz |
| Series | BKSC |
Product Overview
Product Model: BKSC-XX (Rated Capacity)/XX (Voltage Level).Typical Model Example: BKSCKL-15,000/35 Main Application Areas: Substations, User Power Distribution Stations, and other 35kV and below power systems.
Suitable for 35kV and below power systems, with a rated capacity range of 100~16,000kvar, a noise level below 58dB, and F (H) insulation class, for indoor use. Widely applied in substations and user power distribution stations.
Shunt reactors are applied in power systems, connected between phase and ground, phase and neutral, or between phases, to compensate for capacitive currents. They are typically installed at the high-voltage terminal of step-up substations, intermediate interconnection stations, and converter stations of high-voltage direct current transmission, connected in parallel to the 35kV and below low-voltage circuits of substations. They have many functions, such as compensating reactive power in the grid, reducing grid losses, improving transmission capacity, suppressing grid resonance overvoltage, preventing generator self-excitation, eliminating the capacitive effects of unloaded long lines and high-voltage cables, and suppressing power frequency overvoltage, which can save energy and improve the operational stability and reliability of the power system.
Three-Phase rated capacity: 100~16,000kvar
Rated voltage: 35kV and below
Noise level: ≤58dB
Thermal class: F (H)
Usage conditions: indoor

Summarium Producti
Modello Producti: BKSC-XX (Capacitas Nominalis)/XX (Niveles Voltus). Exemplum Modello Typicum: BKSCKL-15,000/35 Principales Areae Applicationis: Stationes Substationales, Stationes Distributionis Potentiae Usuarii, et alia systemata potentiae 35kV et infra.
Adaptatum ad systemata potentiae 35kV et infra, cum amplitudine capacitatis nominalis 100~16,000kvar, nivele soni infra 58dB, et classe insulationis F (H), pro usu intus. Largiter applicatur in stationibus substationalibus et stationibus distributionis potentiae usuarii.
Reactoribus shunt applicantur in systematibus potentiae, coniunctis inter phasim et terram, phasim et neutrum, vel inter phasis, ad compensationem currentium capacitarum. Saepe collocantur ad terminalem altae tensionis stationum substationalium incrementalis, stationum interconnectionis intermediarum, et stationum converteris transmissionis directae currentis altae tensionis, coniunctis in parallelo ad circuitus voltus inferioris 35kV et infra substationum. Habent multas functiones, sicut compensationem potentiae reactivae in reticulo, reductionem perditorum reticuli, meliorationem capacitatis transmissionis, suppressionem overvoltus resonantis reticuli, preventionem autoexcitationis generatoris, eliminationem effectuum capacitarum lineae longae non oneratae et cablorum altae tensionis, et suppressionem overvoltus frequentiae potenciae, quae possunt servare energiam et meliorare stabilitatem et fiduciam operationis systematis potentiae.
Capacitas Nominalis Triphasica: 100~16,000kvar
Voltus Nominalis: 35kV et infra
Nivele Soni: ≤58dB
Classis Thermica: F (H)
Conditiones Usus: intus