Series IMB transformatores electrici alti voltus pro exteris

  • IMB Series HV outdoor current transformers

Attributa principalia

Marca Rockwell
Numerus Modeli Series IMB transformatores electrici alti voltus pro exteris
Votum nominatum 800kV
Series IMB Series

Descriptiones productorum a fornitori

Descriptio

Conspectus

Characteristica principalia
● Unica compositio 'impletionis' olei et quartzi ducit ad designum compactum
● Nulla muto olei vel filtratione requiritur, quia camera expansiva / refrigerans impletur Nitrogeno (N2) / plicae metallica
● Omnes partes externae ferreae sunt pictae MS pro protectione contra effectus detrimentales atmosphaerae et chemicorum
● Magna vis seismicorum tolerabilis in directionibus verticali et horizontali
● Designum flexibile ad satisfaciendum requisitionibus specialibus clientium sicut parva currentes, magna onus, creepage et alta altitudo
● Omnes gaskettes sub nive olei sunt assecurantes positivam sigillatam olei

Primaria bobina

Conductor forma crinis cum insulatio graduata assecurat distributionem uniformem voltus. Bobina insulatur cum charta speciali quae habet magnam fortitudinem mechanicam et dielectricam sicut etiam parvos perditas dielectricas et bonam resistentiam ad senectutem.

Selectio rati est generaliter consecuta per apta secundaria tappata in secundaria bobina.

Pro rationibus in multiplicibus usque et inclusivis 1500 A (sicut 1500-750, 1400-700, 1000-500-250, etc.) selectio potest etiam consecuti per primaria bobina reconnectibilis. Primaria bobina dividitur in partes aequales, quae possunt coniungi in serie vel parallelo per nexos externos in capite connectionis.

Rati tempore brevi currentis (STC) est secundum connexionem seriei primariae bobinae (i.e. sectionem minimum). Cum connexionem parallela, rati STC ergo duplicatur.

Primaria bobina constat tubi aperti utrobique permittentis oleum circulare. Perdita caloris dissipantur in camera expansionis / refrigerante.

Terminal mensurae Tan Delta (terminal D3/F)

Pallium externus primariae insulationis connectitur ad bushing in secundaria terminal box et territus. Hoc designatur ut terminal D3/F.

Hic terminal Tan Delta (D3/F) debet terriri ante CT cargetur.

Nucleus

Transformatores Currentis normaliter possunt accommodare usque ad quinque nuclei. Tamen plus nuclei possunt etiam suppeditari de petito. CRGO ferro-silicio gradus alti utitur pro fabrica nucleorum. Exigentiae accuratae strictae nucleorum metriendi consequuntur per utendum nucleis specialibus factis ex alliage nickel-ferro.

Filiae encausticae gradus alti utuntur pro volvendo secundariis gyris in nucleis. Hi distribuuntur aeque per peripheriam nucleorum, reducendo reactancia leakage ad minimum.

Tank & isolator

Portio inferior CT constat tank aluminii vel MS picta in qua nucleos positionantur circa brachium rectum primariae bobinae. Portio superior transformatoris constat isolatoris glazati brunnei gradus alti facti ex porcellana vel polymer. Gaskettes fiunt ex materia oleo-proof.

Parametri technologici

 

Cognosce tui fornitori
Venditio Online
Ratio praestabilitae tradendae
Tempus responsionis
100.0%
≤4h
Brevis Descriptio Societatis
Locus Operis: 60000m² Numerus omnium laborantium: Summa Annua Exportatio (USD): 100000000
Locus Operis: 60000m²
Numerus omnium laborantium:
Summa Annua Exportatio (USD): 100000000
Servitia
Genus Negotii: Design/Fabricatio/Venditio
Categorias Principales: apparatus electrum altum voltus/transformator
Gubernatio vitae
Servitia gestionis curae integralis pro quaestu, usu, conservatione et post-venditionem apparatus electricorum, securitatem operationis, continuationem imperii et usum electricitatis sine cura garantia.
Fornitori instrumentorum praeteritus est certificationem qualificationis platformae et iudicium technicum, ut ex fonte conformitas, professionalitas et fiducia servantur.

Producta Connexa

Cognitio Connexa

  • Accidentia Transformatoris Principalis et Questiones Operationis Gas Luminis
    1. Registri accidentis (XIX Martii, MMXIX)Hora XVI:XIIX die XIX Martii, MMXIX, monitorium background reportavit actionem gas levis transformatoris principis numeri III. Conformiter Codex Operationis Transformatorum Electricitatis (DL/T572-2010), personale operationis et maintenance (O&M) inspectavit statum in situ transformatoris principis numeri III.Confirmatio in situ: Panel non-electricus protectionis WBH transformatoris principis numeri III reportavit actionem gas levis phase B corpus tr
    02/05/2026
  • Culpae et Tractatio Terrae Unipolaris in Lineis Distributionis 10kV
    Characteristica et Instrumenta Detegendi Defectus Terrae Monofasiales1. Characteristica Defectuum Terrae MonofasialiumSigna Centralia Admonitionis:Campanula admonitionis sonat, et lucerna indicativa inscripta „Defectus Terrae in Sectione Omnibus [X] kV [Y]“ accenditur. In systematibus ubi punctum neutrum per bobinam Petersen (bobinam suppressionis arcus) ad terram connectitur, lucerna indicativa „Bobina Petersen Operatur“ etiam accenditur.Indicationes Voltmetri Monitoris Isolationis:Tensio phase
    01/30/2026
  • Modus operationis terre iunctae puncti neutralis pro transformatoribus retis electricitatis 110kV~220kV
    Dispositio modi operis terrae puncti neutralis pro transformatoribus rete electricitatis 110kV~220kV debet exigentias tolerationis insulationis puncti neutralis transformatorum complere, et simul conari ut impedimentum sequentiae nullae stationum transformationis fere immutatum maneat, dum certatur ne impedimentum sequentiae nullae compositum in quocumque puncto raptus circuiti systematis ultra ter impedimentum sequentiae positivae compositum excedat.Pro transformatoribus 220kV et 110kV in novis
    01/29/2026
  • Cur Quare Substationes Lapidem Gravem Calculos et Rupem Fractam Utuntur
    Cur Quare Substationes Utuntur Lapidibus, Gravibus, Piscinis et Saxis Tritis?In stationibus transformationis, instrumenta ut transformatores electricitatis et distributionis, lineae transmissionis, transformatores tensionis, transformatores currentis et commutatores disiunctionis omnia terram exigunt. Praeter terram, nunc profundius explorabimus cur gravia et saxa trita in stationibus transformationis saepe utuntur. Quamquam videantur ordinaria, isti lapides partem criticam iuxtaque functionalem
    01/29/2026
  • Cur autem nucleus transformatoris tantum in uno puncto terram tangere debet Nonne terra multipuncta fidelius est
    Cur ergo nucleus transformatoris terram tangere debet?In operatione, nucleus transformatoris, simul cum structuris, partibus et componentibus metallicis quae fixant nucleum et spiras, in forti campo electrico situs est. Sub influentia huius campi electrici, potentialem relativum altum ad terram comparatum acquirunt. Si nucleus non terra tangitur, differentia potentialis inter nucleum et structuras claudicantes et vas terratum existet, quae possit ad intermitterentiam dismissionem ducere.Praetere
    01/29/2026
  • Intellegere Terram Neutralis Transformatoris
    I. Quid est Punctum Neutrum?In transformatoribus et generatoribus, punctum neutrum est locus specificus in spira ubi absoluta tensio inter hunc locum et singula terminalia externa aequalis est. In diagrammate infra, punctumOrepraesentat punctum neutrum.II. Cur Punctum Neutrum Terrendum Est?Modus connexionis electricae inter punctum neutrum et terram in systemate AC triphasico diciturmodus terrendi puncti neutri. Hic modus directe afficit:Securitatem, fidem et oeconomiciam retelectrici;Selectione
    01/29/2026

Solutiones Relatae

Non invenisti adhuc opportunos fornitoris ut te inveniant Citationem Nunc Accipe
Non invenisti adhuc opportunos fornitoris ut te inveniant
Citationem Nunc Accipe
Inquiry
+86
Click to upload file
Descarica
Obtine Applicatio Commerciale IEE-Business
Utiliza app IEE-Business ad inveniendum apparatus obtinendumque solutiones coniungendum cum peritis et participandum in collaboratione industriale ubique et semper propter totam supportionem tuorum projectorum electricitatis et negotiorum