• HV500 series engineering single frequency converter
HV500 series engineering single frequency converter
discuss personally
Model
HV500/480V
Basic info
Brand RW Energy
Model NO. HV500 series engineering single frequency converter
Rated frequency 50/60Hz
Series HV
Product Detail

Overview

HV500 series is an engineering single frequency converter with three product concepts: "universal", "easy to use" and "durable" for mid-to-high-end industrial single transmission applications on the basis of inheriting the excellent control performance of HD2000 engineering frequency converters. It can be widely used in metallurgy, nonferrous metals, chemicals, electric power, rubber, cement, lifting, papermaking, mining, textile and municipal industrial occasions.

Performance characteristics

Durability

  • Mechanical vibration level 3M3

  • Independent air duct design

  • Automatic spraying of conformal paint

  • Built-in dynamic junction temperature model to help product safety application

Versatility

  • Certified by a number of international standards and compliant with RoHS Directive

  • Support V/F, OLVC, CLVC control

  • Support multiple communication protocols

  • Support asynchronous and permanent magnet synchronous motors

Ease of use

  • Supports external 24V DC input power supply

  • Built-in brake unit can be used to save installation controls

  • Book-type design supports seamless side-by-side installation

Meet a variety of needs

  • LCD display panel as standard to improve user experience

  • With master-slave control function

  • Expandable communication card, code disk card, voltage detection card

Excellent performance

  • Zero-speed hover

  • Torque response of 1-3ms

  • Excellent robustness

  • Very low dynamic drop and dynamic drop equivalent

  • Accurate off-line/in-line motor model recognition

Quick debugging software in the background

  • Powerful and easy to use

  • Features such as parameter setting, real-time oscilloscope, fault recording, and event recording

Main parameters

project

Specifications and technical data

Power
input
and output

Input voltage Uin

200V (-15%) ~ 240V (+10%) three-phase, 380V (-15%)~480V (+10%) three-phase, 500V (-15%)~690V (+10%) three-phase

Input power frequency

50Hz/60Hz±5%

Input voltage imbalance

≤3%

Output voltage

0V~input voltage

Output frequency

0Hz~500Hz

Power range

2.2kW~560kW

Mainly
control
performance

Motor type

Asynchronous motor/synchronous motor

Control mode

V/F, OLVC (Open-Loop Vector Control), CLVC (Closed-Loop Vector Control)

speed regulation range

1:10  V/F; 1:100  OLVC; 1:1000  CLVC

Start torque

VF:100%(0.5Hz);OLVC:150%(0.5Hz);CLVC:180%(0Hz)

Torque accuracy

≤5%, under vector control mode

Torque pulsation

≤5%, under vector control mode

Steady speed accuracy

OLVC 0.2%; CLVC 0.01%

Torque response

<5ms, under vector control

Dynamic drop equivalent

OLVC<0.5%*s; CLVC<0.3%*s

Increase and deceleration time

0.0s~3200.0s;0.0min~3200.0min

Torque increase

0.0%~30.0%

Overload capacity

150% 1min/5min for heavy-duty applications; Light load application 110% 1min/5min

V/F curve

Various methods: linear VF curve, 5 torque reduction characteristic curve methods; (2.0 powers, 1.8 powers, 1.6 powers, 1.4 powers, 1.2 powers)

User-defined VF curves

Input frequency resolution

The digital setting is 0.01Hz, and the analog setting is 0.01Hz

Main
control
functions

acceleration and deceleration curves

Straight line, S-curve

Multi-speed operation

16 speed operation is achieved through the control terminal

Automatic Voltage Regulation (AVR)

When the grid voltage changes within a certain range, it can automatically keep the output voltage constant

Fixed length control

Given length control

Built-in PID

It can be easily formed as a closed-loop control system

Enhancements

Free function blocks

Input
and output
functions

Frequency setting method

Keyboard given, UP/DOWN terminal, multi-speed give, terminal pulse given, communication

Analog input terminals

AI1: 0V~10V/-10V~10V; AI2 : 0V~10V/0(4)mA~20mA

Digital input terminals

DI1-DI6, 6 programmable digital inputs, optocoupler-isolated, drain/source compatible inputs

Digital input and output terminals

DIO1: Fast pulse output, normal input/output; DIO2: Fast pulse input, normal input/output

Analog output terminals

2 channels 0V~10V/0(4)mA~20mA

Relay output

2-way contact type FormC

Motor temperature detection

Support type PT100/PT1000/KTY84

STO interface

SIL3/PLe level safety torque shutdown function

communication

Communication protocol

Modbus RTU (standard), Profibus, CANopen, profinet, Devicenet, ControlNet

Usage
environment

altitude

no derating is required within 2000 meters above sea level; At an altitude of 2000 meters ~ 4000 meters, the current must be reduced by 1% for every 100 meters of elevation

Ambient temperature

-25&deg;C~+40&deg;C (40&deg;C to 55&deg;C derating is allowed)

humidity

15%~95%, no condensation

vibration

3M3,IEC60721-3-3

Storage temperature

-40℃~+70℃

Place of use

Indoors, there is no direct sunlight, no flammable and corrosive gases, liquids and conductive particles

Options:

code disk card, communication expansion card, voltage detection card

Protection function

Short circuit, overcurrent, overload, overvoltage, undervoltage, phase loss, overheating, external faults, etc

efficiency

5.5kW~22kW:&ge;93%; 30kW and above: &ge;95%

Installation method:

Loading machines and containers

Protection level

IP20

Cooling method

Forced wind cooling

Know your supplier
RW Energy
Zhejiang Rockwell Energy Technology Co., Ltd. is an international enterprise specializing in the research, development and manufacturing of recloser controllers, power quality management, power monitoring systems and other high-end power equipment. In today's critical period of global energy transition and power system upgrading, the company has gathered a group of top talents in the fields of power engineering, automation control, software development, etc., who carry the enthusiasm and persistence for the power business, and are committed to overcoming the complex problems in the power system, and promoting the intelligent development of the power industry with innovative technology. Mission: To make global electricity smarter, more reliable and more efficient with innovative technology. Vision: To be the leader in global power intelligence.
Main Categories
High Voltage Electrical Apparatus/New energy/Tester
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$100000000
Professional Experience
12 years
Workplace
30000m²
占位
占位
Related Products
Related Knowledges
What is the difference between a dielectric and an insulator?
What is the difference between a dielectric and an insulator?
Dielectrics and insulators are distinguished primarily by their applications. One of the main differences is that a dielectric can store electrical energy by becoming polarized in an electric field, whereas an insulator resists the flow of electrons to prevent current conduction. Other key differences between them are outlined in the comparison chart below.Definition of DielectricA dielectric material is a type of insulator that contains few or no free electrons. When subjected to an electric fi
Edwiin
08/30/2025
Fault Analysis and Treatment of Oil-Immersed Transformers
Fault Analysis and Treatment of Oil-Immersed Transformers
Oil Leakage at Welded JointsOil leakage at welded joints primarily stems from poor welding quality, such as incomplete or detached welds, and defects like pinholes and gas pores. Although oil-immersed transformers are initially coated with solder and paint during manufacturing, potentially masking these issues temporarily, the defects tend to surface during operation. Additionally, electromagnetic vibration can cause weld cracks, leading to oil leakage.To resolve such leaks, the first critical s
Edwiin
08/29/2025
What losses occur during operation of the transformer? How to reduce losses?
What losses occur during operation of the transformer? How to reduce losses?
Transformers experience various types of losses during operation, primarily categorized into two main types: copper losses and iron losses.Copper LossesCopper losses, also known as I²R losses, are caused by the electrical resistance of the transformer windings—typically made of copper. As current flows through the windings, energy is dissipated in the form of heat. These losses are proportional to the square of the load current (I²R), meaning they increase significantly with high
Rockwell
08/29/2025
Cable Fault Detection, Testing, Location and Repair
Cable Fault Detection, Testing, Location and Repair
I. Methods for Cable Testing and Inspection:Insulation Resistance Test: Use an insulation resistance tester to measure the insulation resistance value of the cable. A high insulation resistance value indicates good insulation, while a low value may suggest insulation problems requiring further investigation.Voltage Withstand Test: Apply a high-voltage test using a high-voltage tester to verify whether the cable can withstand high voltage under its rated operating conditions. Under normal circums
Leon
08/29/2025
Cable Quality Inspection and Cable Detection & Testing
Cable Quality Inspection and Cable Detection & Testing
Power cable quality inspection and cable testing are conducted to ensure that the cable's quality and performance meet specified requirements, thereby guaranteeing the safe and stable operation of power systems. Below are some common contents of power cable quality inspection and cable testing:Visual Inspection: Check the cable surface for physical defects such as damage, deformation, or scratches to ensure the cable's exterior is intact.Dimensional Measurement: Measure dimensional parameters su
Edwiin
08/29/2025
Transformer Detection, Testing, Maintenance and Servicing
Transformer Detection, Testing, Maintenance and Servicing
Transformer testing, inspection, and maintenance are essential tasks to ensure normal operation and extend the service life of transformers. Below are some recommended steps:Visual Inspection: Regularly inspect the transformer's exterior, including the enclosure, cooling system, and oil tank. Ensure the enclosure is intact, free from corrosion, damage, or leakage.Insulation Resistance Testing: Use an insulation resistance tester to check the transformer's insulation system. Verify that the insul
Vziman
08/29/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!