Circuitus Interruptor Limitans Currentum Altam/Currentum Limitans Circuitus Brevis(FCL)

  • High-Current Current-Limiting Circuit Breaker/Short-Circuit Current Limiter(FCL)

Attributa principalia

Marca Rw Energy
Numerus Modeli Circuitus Interruptor Limitans Currentum Altam/Currentum Limitans Circuitus Brevis(FCL)
Votum nominatum 20kV
currus electricus nominatus 1250A
Frequenta nominata 50/60Hz
Series DDXK

Descriptiones productorum a fornitori

Descriptio

Introductio Producti

Componentis protectivus nuclearis pro systematibus electricis magnae capacitatis (retes 35kV-220kV, areae industriales), FCL responde in ≤10ms ad defectus circuitus brevis. Limitat currentem defectus ad 15%-50% valoris expectati ante fracturam securam, protegens generatores/transformatores. Supportans ratings currentis 630A-4000A, id convenit systematibus AC/DC et integratur cum apparatu commutationis pro operatione retis stabilis.

Characteristica

  • Interruptio Celeris: Operatur et interrumpit currentem defectus in parte frontali primi semicycli frequentiae potentiae defectus—longe antequam currentis ascendat ad suum culmen. Tempus interruptionis totale est 2–5 ms, fere 10–20 vicibus celerius quam interruptores circuitus consuetudinarii.

  • Limitatio Currentis Interruptiva: Incipit limitare currentem defectus 1 ms post defectum, et denique restricts currentem defectus ad 15%–45% valoris expectati.

  • Capacitas Interruptiva Magna: Amplitudo prospectiva rated short-circuit interruptionis currentis variat ab 63 kA ad 200 kA, dum amplitudo rated short-circuit interruptionis currentis interruptorum circuitus communium solito tantum attingit 40.5 kA ad 50 kA.

  • Sensor Currentis Rogowski Integratus: Praebet mensurationem accuratam, celeritatem responsionis velociorem, et potest disponi modo separato per phase aut integrari in armarios apparatorum commutationis.

  • Fides Alta: Una ex competitivis producti est fides eius eminentis. Designatio specialis et artificium asseverant fidem altam producti, quae verificata est et bene accepta in applicationibus in loco.

Parametri Principales

No.

Item


Unitas

Parametri Technici

1

Currentis Rated

A

630~6300

2

Voltage Rated

kV

7.2/12/20/40.5

3

Frequensia Rated

Hz

50/60

4

Rated Prospective Short - Circuit Breaking Current

kA

63/80/120

5

Niveles Insulationis Rated (Frequensia Potentiae / Fulgur)

7.2kV

kV

 23/60 kV

12kV

42/75 kV

20kV

50/125 kV

40.5kV

95/185 kV

6

Tempus Interruptionis


ms

2~5ms

7

Currentis Interruptionis / Peak Value Prospective Short - Circuit Current

%

20~45

8

Resistensia DC Circuiti Principalis

μΩ

<40

9

Range Setting Currentis Operationis

kA

6kA~60kA

10

Rated Breaking Current of Fuse

kA

63/120

11

Rated Short - time Withstand Current of Main Circuit

kA/s

31.5/2

12

Rated Peak Withstand Current of Main Circuit

kA

80

Figura 4: Uti DDXK1 ut protectionis rapidae circuitus brevis pro generatoribus et transformatoribus
(a) Protectio rapidae circuitus brevis ad outlet 10kV/35kV lateris transformatorum
(b) Protectio rapidae circuitus brevis ad outlets generatorum
(c) Protectio rapidae circuitus brevis pro busbaris rami plantarum electricarum
(d) Protectio rapidae circuitus brevis ad outlets generatorum coniunctarum rete

FAQ pro
Q: Quae est resistentia directa circuitus principalis
A:

Minus quam 40 microohmorum (μ Ω), cum conductionis periculis extremis parvis, non afficit normaliter systematis operationis efficientiam.

Q: Quam multum potest amperage post current limiting minui
A:

Fluxus maximus interruptus ad 20% usque ad 45% valoris expectati limitari potest, onus stabilitatis dynamicae et thermicae in apparatus tali qualis transformatores et barras distributivas significantissime minuens.

Q: Quibus tensionibus est DDXK1 idoneus
A:

Copertus 7.2kV, 12kV, 20kV, et 40.5kV, aptus pro systematibus distributionis magnae capacitatis in principibus reteis 35kV ad 220kV et magnis industriarum parvis.

Cognosce tui fornitori
Venditio Online
Ratio praestabilitae tradendae
Tempus responsionis
100.0%
≤4h
Brevis Descriptio Societatis
Locus Operis: 30000m² Numerus omnium laborantium: Summa Annua Exportatio (USD): 100000000
Locus Operis: 30000m²
Numerus omnium laborantium:
Summa Annua Exportatio (USD): 100000000
Servitia
Genus Negotii: Design/Fabricatio/Venditio
Categorias Principales: robot/Energia nova/Instrumenta inspectionis/apparatus electrum altum voltus/Apparatus electri bassa tensione/Instrumenta et mensurae
Gubernatio vitae
Servitia gestionis curae integralis pro quaestu, usu, conservatione et post-venditionem apparatus electricorum, securitatem operationis, continuationem imperii et usum electricitatis sine cura garantia.
Fornitori instrumentorum praeteritus est certificationem qualificationis platformae et iudicium technicum, ut ex fonte conformitas, professionalitas et fiducia servantur.

Producta Connexa

Cognitio Connexa

  • Accidentia Transformatoris Principalis et Questiones Operationis Gas Luminis
    1. Registri accidentis (XIX Martii, MMXIX)Hora XVI:XIIX die XIX Martii, MMXIX, monitorium background reportavit actionem gas levis transformatoris principis numeri III. Conformiter Codex Operationis Transformatorum Electricitatis (DL/T572-2010), personale operationis et maintenance (O&M) inspectavit statum in situ transformatoris principis numeri III.Confirmatio in situ: Panel non-electricus protectionis WBH transformatoris principis numeri III reportavit actionem gas levis phase B corpus tr
    02/05/2026
  • Culpae et Tractatio Terrae Unipolaris in Lineis Distributionis 10kV
    Characteristica et Instrumenta Detegendi Defectus Terrae Monofasiales1. Characteristica Defectuum Terrae MonofasialiumSigna Centralia Admonitionis:Campanula admonitionis sonat, et lucerna indicativa inscripta „Defectus Terrae in Sectione Omnibus [X] kV [Y]“ accenditur. In systematibus ubi punctum neutrum per bobinam Petersen (bobinam suppressionis arcus) ad terram connectitur, lucerna indicativa „Bobina Petersen Operatur“ etiam accenditur.Indicationes Voltmetri Monitoris Isolationis:Tensio phase
    01/30/2026
  • Modus operationis terre iunctae puncti neutralis pro transformatoribus retis electricitatis 110kV~220kV
    Dispositio modi operis terrae puncti neutralis pro transformatoribus rete electricitatis 110kV~220kV debet exigentias tolerationis insulationis puncti neutralis transformatorum complere, et simul conari ut impedimentum sequentiae nullae stationum transformationis fere immutatum maneat, dum certatur ne impedimentum sequentiae nullae compositum in quocumque puncto raptus circuiti systematis ultra ter impedimentum sequentiae positivae compositum excedat.Pro transformatoribus 220kV et 110kV in novis
    01/29/2026
  • Cur Quare Substationes Lapidem Gravem Calculos et Rupem Fractam Utuntur
    Cur Quare Substationes Utuntur Lapidibus, Gravibus, Piscinis et Saxis Tritis?In stationibus transformationis, instrumenta ut transformatores electricitatis et distributionis, lineae transmissionis, transformatores tensionis, transformatores currentis et commutatores disiunctionis omnia terram exigunt. Praeter terram, nunc profundius explorabimus cur gravia et saxa trita in stationibus transformationis saepe utuntur. Quamquam videantur ordinaria, isti lapides partem criticam iuxtaque functionalem
    01/29/2026
  • Cur autem nucleus transformatoris tantum in uno puncto terram tangere debet Nonne terra multipuncta fidelius est
    Cur ergo nucleus transformatoris terram tangere debet?In operatione, nucleus transformatoris, simul cum structuris, partibus et componentibus metallicis quae fixant nucleum et spiras, in forti campo electrico situs est. Sub influentia huius campi electrici, potentialem relativum altum ad terram comparatum acquirunt. Si nucleus non terra tangitur, differentia potentialis inter nucleum et structuras claudicantes et vas terratum existet, quae possit ad intermitterentiam dismissionem ducere.Praetere
    01/29/2026
  • Intellegere Terram Neutralis Transformatoris
    I. Quid est Punctum Neutrum?In transformatoribus et generatoribus, punctum neutrum est locus specificus in spira ubi absoluta tensio inter hunc locum et singula terminalia externa aequalis est. In diagrammate infra, punctumOrepraesentat punctum neutrum.II. Cur Punctum Neutrum Terrendum Est?Modus connexionis electricae inter punctum neutrum et terram in systemate AC triphasico diciturmodus terrendi puncti neutri. Hic modus directe afficit:Securitatem, fidem et oeconomiciam retelectrici;Selectione
    01/29/2026
Non invenisti adhuc opportunos fornitoris ut te inveniant Citationem Nunc Accipe