• HD8000 series medium voltage engineering frequency converter
  • HD8000 series medium voltage engineering frequency converter
HD8000 series medium voltage engineering frequency converter
discuss personally
Model
HD8000
Basic info
Brand RW Energy
Model NO. HD8000 series medium voltage engineering frequency converter
Rated frequency 50/60Hz
Series HD
Product Detail

Overview

1.65kV、2.4kV、3.3kV、4.16kV、6.6kV、10kV、13.8kV、19.8kV; 8MVA~102MVA (stand-alone), which can support up to eight machines in parallel.

Performance characteristics

Engineered reliability design

  • IGCT fault and judgment + bridge arm pass-through protection technology

  • Redundancy design and fault tolerance designof key components

  • IP54 protection design, C4-M anti-corrosion design

  • Double-sided crimped structure power devices

Modular design

  • Modular design of key components

  • Intelligent fault diagnosis system for quick positioning

  • Phase module disassembly time only takes 15 minutes, making maintenance simple and fast

Excellent control

  • Four-quadrant operation to meet the electric and brake energy feedback

  • Adaptable to asynchronous induction motor, permanent magnet synchronous motor and electric excitation synchronous motor

  • Fast torque dynamic response and torsional vibration suppressionfunction

  • Segmented synchronous modulation of the motor to meet the requirements of high speed regulation range such as steel rolling and hoist

  • SHEPWM (specific harmonic cancellation pulse width modulation)

Adaptable

  • Single-motor transmission configuration/multi-motor transmission configuration

  • High-altitude design: no derating required for use within 2000m

  • Grid adaptability design: The system has the ability to adapt to grid imbalance, power grid harmonics, grid frequency flicker, grid transient drop, and high and low voltage cross-ride.

Communication Protocols & Smart Software

  • Customizable communication protocol

  • Powerful monitoring system can monitor internal data, waveforms, etc. in real time

  • Provide fast debugging tool hopeInsight for quick network debugging

International leading level technology

  • "High-power IGCT AC and Orthogonal Frequency Conversion Speed Regulation Device" and "Key Technologies and Applications of High-Power IGCT AC Orthogonal Frequency Conversion Speed Regulation System" have been identified as international advanced level, and a number of technologies have been identified as international leading level

Main parameters

project

Specifications and technical data

Basic rectification

Input frequency

45Hz~66Hz

Fundamental power factor

≥ 95% (based on 12 pulses and above, rated current, equipped with 2% current input reactor)

PWM rectification

Input frequency

45Hz~66Hz

Factor

1 (Continuously settable)

Protection function

Overload protection, overheat protection, short circuit protection, fault prediction, etc

Inverse

Output voltage

1:1.65kV,2:2.4kV,3:3.3kV, 4:4.16kV,6:6.6kV,

A:10kV,B:13.8kV,C:19.8kV

Output frequency

0~110Hz (higher output frequency can be customized according to requirements)

Steady speed accuracy

OLVC:0.2% ; CLVC:0.01%

Pulsating speed

OLVC:0.4% ; CLVC:0.2%

Start torque

OLVC:150%; CLVC:200%   

Torque control

V/F: Support ; OLVC: Support; CLVC: Yes

Torque accuracy

OLVC:5% ; CLVC: 2% (customizable)

Torque response time

≤5ms

RPM response time

OLVC:100ms ;  CLVC:100ms

Dynamic drop equivalent

OLVC:0.5%*s ;  CLVC:0.25%*s

Machine

efficiency

Second quadrant: ≥99% (excluding rectifier transformer)

Quadrant 4: ≥ 98.5% (excluding rectifier transformer)

temperature

Inlet water temperature ≤35°C (outside water)

elevation

≤2000m (2000m~4000m reduced use)

Protection level

IP54

Cooling method

Water

Anti-corrosion grade

C4-M

 

Know your supplier
RW Energy
Zhejiang Rockwell Energy Technology Co., Ltd. is an international enterprise specializing in the research, development and manufacturing of recloser controllers, power quality management, power monitoring systems and other high-end power equipment. In today's critical period of global energy transition and power system upgrading, the company has gathered a group of top talents in the fields of power engineering, automation control, software development, etc., who carry the enthusiasm and persistence for the power business, and are committed to overcoming the complex problems in the power system, and promoting the intelligent development of the power industry with innovative technology. Mission: To make global electricity smarter, more reliable and more efficient with innovative technology. Vision: To be the leader in global power intelligence.
Main Categories
High Voltage Electrical Apparatus/New energy/Tester
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$100000000
Professional Experience
12 years
Workplace
30000m²
占位
占位
Related Products
Related Knowledges
What is the difference between a dielectric and an insulator?
What is the difference between a dielectric and an insulator?
Dielectrics and insulators are distinguished primarily by their applications. One of the main differences is that a dielectric can store electrical energy by becoming polarized in an electric field, whereas an insulator resists the flow of electrons to prevent current conduction. Other key differences between them are outlined in the comparison chart below.Definition of DielectricA dielectric material is a type of insulator that contains few or no free electrons. When subjected to an electric fi
Edwiin
08/30/2025
Fault Analysis and Treatment of Oil-Immersed Transformers
Fault Analysis and Treatment of Oil-Immersed Transformers
Oil Leakage at Welded JointsOil leakage at welded joints primarily stems from poor welding quality, such as incomplete or detached welds, and defects like pinholes and gas pores. Although oil-immersed transformers are initially coated with solder and paint during manufacturing, potentially masking these issues temporarily, the defects tend to surface during operation. Additionally, electromagnetic vibration can cause weld cracks, leading to oil leakage.To resolve such leaks, the first critical s
Edwiin
08/29/2025
What losses occur during operation of the transformer? How to reduce losses?
What losses occur during operation of the transformer? How to reduce losses?
Transformers experience various types of losses during operation, primarily categorized into two main types: copper losses and iron losses.Copper LossesCopper losses, also known as I²R losses, are caused by the electrical resistance of the transformer windings—typically made of copper. As current flows through the windings, energy is dissipated in the form of heat. These losses are proportional to the square of the load current (I²R), meaning they increase significantly with high
Rockwell
08/29/2025
Cable Fault Detection, Testing, Location and Repair
Cable Fault Detection, Testing, Location and Repair
I. Methods for Cable Testing and Inspection:Insulation Resistance Test: Use an insulation resistance tester to measure the insulation resistance value of the cable. A high insulation resistance value indicates good insulation, while a low value may suggest insulation problems requiring further investigation.Voltage Withstand Test: Apply a high-voltage test using a high-voltage tester to verify whether the cable can withstand high voltage under its rated operating conditions. Under normal circums
Leon
08/29/2025
Cable Quality Inspection and Cable Detection & Testing
Cable Quality Inspection and Cable Detection & Testing
Power cable quality inspection and cable testing are conducted to ensure that the cable's quality and performance meet specified requirements, thereby guaranteeing the safe and stable operation of power systems. Below are some common contents of power cable quality inspection and cable testing:Visual Inspection: Check the cable surface for physical defects such as damage, deformation, or scratches to ensure the cable's exterior is intact.Dimensional Measurement: Measure dimensional parameters su
Edwiin
08/29/2025
Transformer Detection, Testing, Maintenance and Servicing
Transformer Detection, Testing, Maintenance and Servicing
Transformer testing, inspection, and maintenance are essential tasks to ensure normal operation and extend the service life of transformers. Below are some recommended steps:Visual Inspection: Regularly inspect the transformer's exterior, including the enclosure, cooling system, and oil tank. Ensure the enclosure is intact, free from corrosion, damage, or leakage.Insulation Resistance Testing: Use an insulation resistance tester to check the transformer's insulation system. Verify that the insul
Vziman
08/29/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!