• 6.6kV Three-phase Power Distribution Transformer
6.6kV Three-phase Power Distribution Transformer
discuss personally
Model
S11-1500/6.6
Basic info
Brand Vziman
Model NO. 6.6kV Three-phase Power Distribution Transformer
Rated capacity 1500kVA
Voltage grade 6.6KV
Series Distribution Transformer
Product Detail

Product overview:

  • High reliability of operation verification in more than 50 countries and regions around the world.

  • Mainly used in power generation enterprises, industrial and mining enterprises, water conservancy facilities, petrochemical enterprises 6.6 kV power distribution system.

  • Products are mainly exported to southeast Asia, East Asia, Central Asia and other developing countries and regions.

  • Standards: IEC 60076 series, IEC 6013, IEC 60214-1, IEC 60296; GB1094 series, GB/T6451-2015, GB/T7597-2007, etc.

Product advantages

Leading technology:

  • High pressure copper tape winding technology, improve lightning resistance.

  • Low voltage copper foil winding technology, high quality A class insulation material insulation.

  • Small magnetic leakage, high mechanical strength, strong short circuit resistance.

  • Iron core 45° full oblique joint step laminated structure.

The shell:

  • Mitsubishi laser cutting machine and CNC punching, reducing, folding and other equipment to ensure the accuracy of processing.

  • ABB robot automatic welding, laser detection, to avoid leakage, qualified rate of 99.99998%.

  • Electrostatic spray treatment, 50 years of paint (coating corrosion resistance within 100h, hardness ≥0.4.

  • Fully sealed structure, maintenance-free and maintenance-free, normal operation life of more than 30 years.

The iron core

  • The core material is high quality cold rolled grain oriented silicon steel sheet with mineral oxide insulation (from Baosteel, Wisco, China).

  • Minimize loss level, no-load current and noise by controlling the cutting and stacking process of silicon steel sheet.

  • The iron core is specially reinforced to ensure the transformer structure is firm during normal operation and transportation.

winding:

  • Low voltage winding is made of high quality copper foil, excellent insulation resistance.

  • The high voltage windings are usually made of insulated copper wire, using the patented technology of Hengfengyou Electric.

  • Very good resistance to radial stress caused by short circuit.

 High quality material:

  •  Baowu Steel Group production of silicon steel sheet.

  • High quality anaerobic copper from China.

  • CNPC (Kunlun Petroleum) High quality transformer oil (25# 40#).

 Other instructions:

  • The low-voltage outgoing terminal is tinned copper bar.

  • The high-voltage outlet terminals are ring tinned bolts.

  • Default no-load voltage regulation (on-load voltage regulation can be customized) Tap switch 5 or 7 speed adjustment.

  • Transformers above 630KVA are protected by gas relays.

Ordering instructions:

  • Main parameters of transformer (voltage, capacity, loss and other main parameters.

  • Transformer operating environment (altitude, temperature, humidity, location, etc.

  • Other customization requirements (tap switch, color, oil pillow, etc.

  • The minimum order quantity is 1 sets, worldwide delivery within 7 days.

    Normal delivery period of 30 days, worldwide fast delivery.

How to choose the parameters of three-phase distribution transformer?

Main Parameters of a Transformer

Rated Capacity:

  • Definition: The rated capacity of a transformer is the apparent power it can output under rated operating conditions. The unit is kilovolt-amperes (kVA) or megavolt-amperes (MVA).

  • Common Values: For a common 6.6 kV three-phase distribution transformer, the rated capacities include 100 kVA, 200 kVA, 315 kVA, 400 kVA, 500 kVA, 630 kVA, etc.

Rated Voltage:

  • Definition: Rated voltage includes the rated voltage on the high-voltage side and the rated voltage on the low-voltage side.

  • Example: For a 6.6 kV transformer, 6.6 kV is the rated voltage on the high-voltage side. The rated voltage on the low-voltage side is typically 0.4 kV or 0.69 kV, depending on the user's requirements.

Short-Circuit Impedance:

  • Definition: Short-circuit impedance is an important parameter of a transformer, indicating the impedance of the transformer under short-circuit conditions. The size of the short-circuit impedance affects the short-circuit current and the voltage drop during a short circuit, which is significant for the protection and operational stability of the transformer.

No-Load Loss:

  • Definition: No-load loss is the power consumed by the transformer when it is in a no-load state (i.e., the secondary side is open). It primarily includes hysteresis losses and eddy current losses in the core, as well as resistance losses in the windings. The smaller the no-load loss, the higher the efficiency of the transformer.

Load Loss:

  • Definition: Load loss is the power consumed by the transformer when it is in a loaded state (i.e., the secondary side is connected to a load). It primarily includes resistance losses in the windings and additional losses due to leakage flux. Load loss is proportional to the square of the load current and is an important indicator of transformer performance.

  • This translation provides a clear and concise explanation of the main parameters of a transformer, including rated capacity, rated voltage, short-circuit impedance, no-load loss, and load loss.

Know your supplier
Vziman
Zhejiang Vziman Electric Group Co., Ltd. is a high-tech enterprise specializing in R&D, manufacturing, and service of power electrical equipment. Committed to innovation, quality, and customer satisfaction, it supplies smart solutions for global power sectors, covering grid construction, new energy, and industrial distribution. Core Business • Switchgear (GIS, circuit breakers, Recloser, Load break switch) • Distribution equipment (transformers, RMU, smart terminals) • Power automation systems • Engineering services (installation, maintenance, consulting) Technical Strength • Provincial R&D center, multiple patents • Modern production, ISO/GB/IEC/CE/UL certified • High capacity, large-scale delivery support Market & Vision Serves State Grid, Southern Grid, and global projects (Asia, Africa, Europe, etc.). Aims to lead in smart grids and new energy, promoting sustainable energy development.
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150000000
Professional Experience
3 years
Workplace
10000m²
占位
占位
Related Products
Related Knowledges
What is the difference between a dielectric and an insulator?
What is the difference between a dielectric and an insulator?
Dielectrics and insulators are distinguished primarily by their applications. One of the main differences is that a dielectric can store electrical energy by becoming polarized in an electric field, whereas an insulator resists the flow of electrons to prevent current conduction. Other key differences between them are outlined in the comparison chart below.Definition of DielectricA dielectric material is a type of insulator that contains few or no free electrons. When subjected to an electric fi
Edwiin
08/30/2025
Fault Analysis and Treatment of Oil-Immersed Transformers
Fault Analysis and Treatment of Oil-Immersed Transformers
Oil Leakage at Welded JointsOil leakage at welded joints primarily stems from poor welding quality, such as incomplete or detached welds, and defects like pinholes and gas pores. Although oil-immersed transformers are initially coated with solder and paint during manufacturing, potentially masking these issues temporarily, the defects tend to surface during operation. Additionally, electromagnetic vibration can cause weld cracks, leading to oil leakage.To resolve such leaks, the first critical s
Edwiin
08/29/2025
What losses occur during operation of the transformer? How to reduce losses?
What losses occur during operation of the transformer? How to reduce losses?
Transformers experience various types of losses during operation, primarily categorized into two main types: copper losses and iron losses.Copper LossesCopper losses, also known as I²R losses, are caused by the electrical resistance of the transformer windings—typically made of copper. As current flows through the windings, energy is dissipated in the form of heat. These losses are proportional to the square of the load current (I²R), meaning they increase significantly with high
Rockwell
08/29/2025
Cable Fault Detection, Testing, Location and Repair
Cable Fault Detection, Testing, Location and Repair
I. Methods for Cable Testing and Inspection:Insulation Resistance Test: Use an insulation resistance tester to measure the insulation resistance value of the cable. A high insulation resistance value indicates good insulation, while a low value may suggest insulation problems requiring further investigation.Voltage Withstand Test: Apply a high-voltage test using a high-voltage tester to verify whether the cable can withstand high voltage under its rated operating conditions. Under normal circums
Leon
08/29/2025
Cable Quality Inspection and Cable Detection & Testing
Cable Quality Inspection and Cable Detection & Testing
Power cable quality inspection and cable testing are conducted to ensure that the cable's quality and performance meet specified requirements, thereby guaranteeing the safe and stable operation of power systems. Below are some common contents of power cable quality inspection and cable testing:Visual Inspection: Check the cable surface for physical defects such as damage, deformation, or scratches to ensure the cable's exterior is intact.Dimensional Measurement: Measure dimensional parameters su
Edwiin
08/29/2025
Transformer Detection, Testing, Maintenance and Servicing
Transformer Detection, Testing, Maintenance and Servicing
Transformer testing, inspection, and maintenance are essential tasks to ensure normal operation and extend the service life of transformers. Below are some recommended steps:Visual Inspection: Regularly inspect the transformer's exterior, including the enclosure, cooling system, and oil tank. Ensure the enclosure is intact, free from corrosion, damage, or leakage.Insulation Resistance Testing: Use an insulation resistance tester to check the transformer's insulation system. Verify that the insul
Vziman
08/29/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!