GRV8-1UVR Relais de Tension Inférieure Monophasé

  • GRV8-1UVR Single Phase Undervoltage Relay

Attributa principalia

Marca Switchgear parts
Numerus Modeli GRV8-1UVR Relais de Tension Inférieure Monophasé
Frequenta nominata 45Hz-65Hz
Series GRV8

Descriptiones productorum a fornitori

Descriptio

Product Highlight:

Protegimento Fidelis: Praesidium pro motoribus, systematibus aeris conditi, et aliis oneribus inductivis ab conditionibus subvoltage noxiis.

Mensura Veri RMS: Praebet praecisam observationem voltage, etiam in ambientibus cum harmonicis vel formis undarum distortis.

Lata Compatibilitas: Functio in ambitu 45Hz ad 65Hz, adaptabilis ad diversa systemata electrica.

Alta Praecisio: Offert accuratam mensuram voltage minus quam 1% pro performance constans.

Design Amicus Usoris: Habet indicatorem status LED et formatum compactum 1-MODULE pro facili montatura in rail DIN.

GEYA GRV8-1UVR est relais subvoltage uniphasicum specialiter designatum pro usibus industrialibus et commercialibus. Destinatum est ad protegendum onera inductiva, sicut systemata aeris conditi et motores, ab damno causato per fluctuationes subvoltage repentinas. Utilizando technologiam advancedam mensurae veri RMS, hoc instrumentum continenter monitorat tensionem supply in tempore reali et prompte disjungit onus quando voltage cadit sub limen praestabilitum, efficaciter preveniens damnum aequipmentorum et interruptiones productionis.

Function: Subvoltage

Tensio supply nominata (Un):220V/230V/240V

Frequensia supply nominata:45Hz-65Hz

Limen subvoltage:Fixum 75% de Un

Applicationes:

Productus utilisatur pro oneribus inductivis fluctuantibus maxime sicut Aer.

Conditioning system in Industrial and commercial establishments.

Protexit systematis aequipmentorum et oneris ab fluctuationibus subvoltage repentinis.

Item GRV8-1UVR Relais Subvoltage Uniphasicum
Function Subvoltage
Terminales monitoring L-N
Terminales supply L-N
Tensio supply nominata (Un) 220V/230V/240V
Frequensia supply nominata 45Hz-65Hz
Limen subvoltage R:fixum 75% de Un
Tempus morae disjunctio (Tu) 0.1s
Hysteresis 5V
Error mensurae ≤1%
Tempus morae supply (Td) Adjustabile: 5min-15min
Tempus morae recuperationis (Tr) Adjustabile: 5min-15min
Accuratia setting konb 10% de scala valoris
Indicatio supply LED viridis
Indicatio output LED rubrum
Output 1×SPDT
Rating currentis 10A/AC1
Voltage commutationis 250VAC/24VDC
Vita mechanica 1*107
Vita electrica (AC1) 1*105
Temperatura operationis -20℃ ad +55℃(-4℉ ad 131℉)
Temperatura storage -35℃ ad +75℃(-22℉ ad 158℉)
Montage/DIN rail Din rail EN/IEC 60715
Gradus protectionis IP40 pro fronte panel/IP20 terminales
Positio operationis cualibet
Categoria overvoltage III
Gradus pollutionis 2
Max.Cable size(mm²) solid wire max.1×2.5or 2×1.5/with sleeve max.1×2.5(AWG 12)
Torque tightening 0.8Nm
Dimensiones 90×18×64mm
Pondus 63g,65g
Standards EN 60255-1,IEC60947-5-1
Cognosce tui fornitori
Venditio Online
Ratio praestabilitae tradendae
Tempus responsionis
100.0%
≤4h
Brevis Descriptio Societatis
Locus Operis: 1000m² Numerus omnium laborantium: Summa Annua Exportatio (USD): 300000000
Locus Operis: 1000m²
Numerus omnium laborantium:
Summa Annua Exportatio (USD): 300000000
Servitia
Genus Negotii: Venditio
Categorias Principales: pars componentium/Instrumenta inspectionis/apparatus electrum altum voltus/Apparatus electri bassa tensione/Instrumenta et mensurae/Instrumenta productiva/Ferramentae electricitatis
Gubernatio vitae
Servitia gestionis curae integralis pro quaestu, usu, conservatione et post-venditionem apparatus electricorum, securitatem operationis, continuationem imperii et usum electricitatis sine cura garantia.
Fornitori instrumentorum praeteritus est certificationem qualificationis platformae et iudicium technicum, ut ex fonte conformitas, professionalitas et fiducia servantur.

Producta Connexa

Cognitio Connexa

  • Accidentia Transformatoris Principalis et Questiones Operationis Gas Luminis
    1. Registri accidentis (XIX Martii, MMXIX)Hora XVI:XIIX die XIX Martii, MMXIX, monitorium background reportavit actionem gas levis transformatoris principis numeri III. Conformiter Codex Operationis Transformatorum Electricitatis (DL/T572-2010), personale operationis et maintenance (O&M) inspectavit statum in situ transformatoris principis numeri III.Confirmatio in situ: Panel non-electricus protectionis WBH transformatoris principis numeri III reportavit actionem gas levis phase B corpus tr
    02/05/2026
  • Culpae et Tractatio Terrae Unipolaris in Lineis Distributionis 10kV
    Characteristica et Instrumenta Detegendi Defectus Terrae Monofasiales1. Characteristica Defectuum Terrae MonofasialiumSigna Centralia Admonitionis:Campanula admonitionis sonat, et lucerna indicativa inscripta „Defectus Terrae in Sectione Omnibus [X] kV [Y]“ accenditur. In systematibus ubi punctum neutrum per bobinam Petersen (bobinam suppressionis arcus) ad terram connectitur, lucerna indicativa „Bobina Petersen Operatur“ etiam accenditur.Indicationes Voltmetri Monitoris Isolationis:Tensio phase
    01/30/2026
  • Modus operationis terre iunctae puncti neutralis pro transformatoribus retis electricitatis 110kV~220kV
    Dispositio modi operis terrae puncti neutralis pro transformatoribus rete electricitatis 110kV~220kV debet exigentias tolerationis insulationis puncti neutralis transformatorum complere, et simul conari ut impedimentum sequentiae nullae stationum transformationis fere immutatum maneat, dum certatur ne impedimentum sequentiae nullae compositum in quocumque puncto raptus circuiti systematis ultra ter impedimentum sequentiae positivae compositum excedat.Pro transformatoribus 220kV et 110kV in novis
    01/29/2026
  • Cur Quare Substationes Lapidem Gravem Calculos et Rupem Fractam Utuntur
    Cur Quare Substationes Utuntur Lapidibus, Gravibus, Piscinis et Saxis Tritis?In stationibus transformationis, instrumenta ut transformatores electricitatis et distributionis, lineae transmissionis, transformatores tensionis, transformatores currentis et commutatores disiunctionis omnia terram exigunt. Praeter terram, nunc profundius explorabimus cur gravia et saxa trita in stationibus transformationis saepe utuntur. Quamquam videantur ordinaria, isti lapides partem criticam iuxtaque functionalem
    01/29/2026
  • Cur autem nucleus transformatoris tantum in uno puncto terram tangere debet Nonne terra multipuncta fidelius est
    Cur ergo nucleus transformatoris terram tangere debet?In operatione, nucleus transformatoris, simul cum structuris, partibus et componentibus metallicis quae fixant nucleum et spiras, in forti campo electrico situs est. Sub influentia huius campi electrici, potentialem relativum altum ad terram comparatum acquirunt. Si nucleus non terra tangitur, differentia potentialis inter nucleum et structuras claudicantes et vas terratum existet, quae possit ad intermitterentiam dismissionem ducere.Praetere
    01/29/2026
  • Intellegere Terram Neutralis Transformatoris
    I. Quid est Punctum Neutrum?In transformatoribus et generatoribus, punctum neutrum est locus specificus in spira ubi absoluta tensio inter hunc locum et singula terminalia externa aequalis est. In diagrammate infra, punctumOrepraesentat punctum neutrum.II. Cur Punctum Neutrum Terrendum Est?Modus connexionis electricae inter punctum neutrum et terram in systemate AC triphasico diciturmodus terrendi puncti neutri. Hic modus directe afficit:Securitatem, fidem et oeconomiciam retelectrici;Selectione
    01/29/2026
Non invenisti adhuc opportunos fornitoris ut te inveniant Citationem Nunc Accipe
Non invenisti adhuc opportunos fornitoris ut te inveniant
Citationem Nunc Accipe
Inquiry
+86
Click to upload file
Descarica
Obtine Applicatio Commerciale IEE-Business
Utiliza app IEE-Business ad inveniendum apparatus obtinendumque solutiones coniungendum cum peritis et participandum in collaboratione industriale ubique et semper propter totam supportionem tuorum projectorum electricitatis et negotiorum