• DS7B 72.5kV 145kV 252kV 363kV 420kV 550kV 800kV High voltage disconnect switch
DS7B 72.5kV 145kV 252kV 363kV 420kV 550kV 800kV High voltage disconnect switch
discuss personally
Model
DS7B-800D/5000-63
DS7B-550D/3150-63
DS7B-420D/3150-63
DS7B-363D/5000-63
DS7B-363D/3150-63
DS7B-252D/5000-63
DS7B-252D/4000-63
DS7B-252D/3150-50
DS7B-252D/2500-50
DS7B-252D/2000-50
DS7B-145D/2000-40
DS7B-145D/1250-31.5
DS7B-72.5D/4000-50
DS7B-72.5D/3150-50
DS7B-72.5D/2500-50
DS7B-72.5D/2000-40
DS7B-72.5D/1250-40
Basic info
Brand ROCKWILL
Model NO. DS7B 72.5kV 145kV 252kV 363kV 420kV 550kV 800kV High voltage disconnect switch
Rated voltage 800kV
Rated normal current 5000A
Rated frequency 60hz
Rated peak value withstand current 160kA
Rated short-time withstand current 63kA
Series DS7B
Product Detail

Product introduction

DSDS7B series Switch Disconnector is a kind of outdoor HV electricity transmission equipment’s at three-phase AC frequency of 50Hz/60Hz. it is used for breaking or correcting HV lines under no loads so that these lines can be changed and connected and the way the electricity runs is changed. in addition, it can be used to exercise safe electrical insulation for such HV electric apparatuses as bus and breaker. The switch can open and close inductance/capacitance currant and is able to open and close the bus to switch current.

This product has three posts with horizontal open breaks. JW10 grounding switches may be attached to the product at one or two sides 72.5-252kV Switch Disconnector adopts C2 or SRCJ2 manual actuator to realize the tri-pole linkage. The earthing switch adopts CS11 or SRCR manual actuator to actualize tr-pole linkage,.363kV disconnect switch adopts SRCJ2 motor's actuator to realize the single pole operation; while the earthing switch takes SRCS manual actuator or SRCJ2 motor's actuator to realize the single pole operation and also tri-pole linkage.

This product has been verified by the Chinese competent authority as having uniqueness in design and reaching international advanced level of similar products.

GW7B Switch Disconnector comprises three single poles and actuator. Each single pole is made of a base, post insulator and conductive part. Three insulating posts are installed onto a long base, with two static contacts mounted at both ends to fix the top of the insulating post, and the conductive knife switch mounted onto the top of the rotating insulating post in between.

The actuator drives the rotating post in the middle to bring the conductive knife switch circumgyrate to open or close the breaker by contacting or detaching the static contacts fixed on the both ends of the post, Two horizontal insulating open breaks in series will appear at the closing moment.

In the opening and closing process, the conductive knife switch will horizontally swing and auto-rotate, with the aid of the turnover mechanism, to reduce the operating force and impact that occur in the opening and closing process and to improve the contact’s ability self-cleaning.

Main characteristic

  • The Switch Disconnector is of the turnover-type, and the conductive tube will move in two steps. At the closing moment, the conductive tube will rotate by some 70" on the horizontal surface, When the contacts at both ends are blocked up after having been placed in the static contact base, the turnover mechanism will drive the conductive tube to auto-rotate by about 45° when the movable contact will be in reliable contact with the touch finger. This process requires small operating force, thus causing no impacts on the insulators fixed at both ends. The main contact has the self-cleaning ability.
  • One end of the U-shaped finger within the static contact is fixed onto the contact base, forming a fixed connection and ensuring the reliable conduction; while the other end will produce contact pressure on the movable contact as a result of the influence of external spring and the own elastic force of the contact finger, and the gripping force will automatically increase when the short-circuit current passes through the contact. The contact spring is made of stainless steel and is equipped with insulating gasket, The spring will not corrupt nor shunt.
  • Provide one-key sequential control "double confirmation" function expansion.
  • The rotating parts of the disconnect switch are designed to be free of maintenance. The rotating base is designed into a closure structure which denies the access of moisture, dust and harmful gases so that the low-temperature lubricating cream within the bearing will not run off or harden.
  • 363kV and above earthing switch is in the single-arm standing and openable structure, with the structurally simple plug-type contact, The conductive rod for grounding will move in twosteps at the moments of opening and closing. At the moment of closing, the conductive rod will rotate vertically and rise up lo the fixed contact, and then automatically plug itself into the star-shaped contact, By doing so, the contact will be made reliable and be able to sustain the heavy short-circuit current.

Main technical parameters

Order notice 

Product model, rated voltage, rated current, rated short-time withstand current, creepage distance and method of combination must be specified at the goods ordering time;

The methods of attaching earthing switches to Switch Disconnectores (left, right and both left and right);

Note: the way to judge the method of grounding: when one faces the name plate, the left grounding will be confirmed if the earthing switch is at the left hand side, and right grounding if at the right hand side;

The actuator's model and name, motor's voltage, control voltage and the number of contacts for auxiliary switch;

Current transformers are ordered by purchasers; however, it must be ensured that fixed contacts can be mounted onto such transformers:

When the Switch Disconnector is used at the incoming and outgoing terminals of the substation in the double loop parallel overhead power transmission line, if the earthing switch requires the opening/closing induction current, then such requirement shall be specified, Besides, the parameters and the side at which the earthing switch is set shall be defined. (Special notice: Not all earthing switches attached to the earthing switches and disconnect switches at the substation shall require the opening/closing induction current.)

 

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Analysis of Transformer Capacity, Load Rate and Number of Units Selection Issues
Analysis of Transformer Capacity, Load Rate and Number of Units Selection Issues
The safe and economical operation of power transformers is related to the safety, economy, stability, and reliability of the operations of various industries. The limitations of conditions such as the investment economic indicators for its selection, the economic benefits of maintenance and operation, and the adaptability in the new environment (access of distributed power sources, configuration of energy storage, etc.) make it impossible to include comprehensive factors in other aspects.The cap
Leon
07/17/2025
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
1 IntroductionLow - voltage current transformers for metering, with a through - core type epoxy resin structure, are widely used in distribution transformer areas and for small - to - medium - sized industrial and commercial electricity consumption. As a range expander for electric energy metering, their performance directly relates to electricity consumption safety and the accuracy of users' trade calculations. Studying long - term immersion's impact on these transformers is practically signifi
Felix Spark
07/17/2025
What is reactive power measurement?
What is reactive power measurement?
The power which exists in the circuit when the voltage and current are out of phase to each other, such type of power is known as the reactive power. The formula measures the reactive power in the circuitReactive Power Measurement & VarmetersReactive power measurement is critical as it indicates circuit power loss: low reactive power worsens load power factor, increasing system losses. Varmeters (volt-ampere reactive meters) measure reactive power and are categorized by circuit phases:Single
Edwiin
07/17/2025
How to Design and Install a Solar PV System?
How to Design and Install a Solar PV System?
Design and Installation of Solar PV SystemsModern society relies on energy for daily needs like industry, heating, transport, and agriculture, mostly met by non-renewable sources (coal, oil, gas). However, these cause environmental harm, are unevenly distributed, and face price volatility due to limited reserves—driving demand for renewable energy.Solar energy, abundant and capable of meeting global needs, stands out. Standalone PV systems (Fig 1) offer energy independence from utilities.
Edwiin
07/17/2025
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
Low-voltage current transformers, as indispensable measurement and protection devices in power systems, often encounter various faults when used in combination with other power equipment due to environmental factors, equipment linkage issues, and improper installation and maintenance. These faults not only affect the normal operation of power equipment but may also endanger personal safety. Therefore, it is necessary to gain an in-depth understanding of fault types, judgment methods, and prevent
Felix Spark
07/17/2025
What are the monitoring methods and future development trends of low-voltage voltage transformers?
What are the monitoring methods and future development trends of low-voltage voltage transformers?
With the continuous advancement of smart grid technology, intelligent monitoring systems are playing an increasingly important role in preventing and addressing faults in voltage transformers. These modern intelligent monitoring systems can collect key parameters from voltage transformers in real time—such as partial discharge levels, temperature, and oil quality—and use data analysis algorithms to assess the health status of the equipment, enabling early fault warnings and precise l
Echo
07/16/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!