DS5A 40.5kV 72.5kV 126kV disiector superior voltaginis altae

  • DS5A 40.5kV 72.5kV 126kV High voltage disconnect switch source supplier

Attributa principalia

Marca ROCKWILL
Numerus Modeli DS5A 40.5kV 72.5kV 126kV disiector superior voltaginis altae
Votum nominatum 40.5kV
currus electricus nominatus 1250A
Frequenta nominata 50/60Hz
Valorem culminis tolerabilis 50kA
Rated short-time withstand current 20kA
Series DS5A

Descriptiones productorum a fornitori

Descriptio

Introductio producti:

DS5A Interruptor Disiunctivus est genus apparati electricitatis ad altum tensio pro transmissione foris. Adhibetur ad disiungendum vel iungendum lineas ad altum tensio sine onere, ut lineae electricitatis possint mutari et iungi, et via qua electricitas currit mutari. Praeterea, adhiberi potest ad exercendam securam insulationem electricam pro talibus apparatibus electricis ad altum tensio sicut bus et interruptor.

Hoc productum habet duas columnas cum rupituris apertis horizontaliter. Est apertabilis in medio et accessibilis ad interruptorem terrae ex una parte vel ex utraque parte. Interruptores disiunctivi et terre cum motu 90° adoptant mechanismum manuale operativum CS11 ad exequendam tri-polaris nexus; interruptores disiunctivi cum motu 180° adoptant mechanismum manuale operativum CS11 vel CS14g ad exequendam tri-polaris nexus; interruptor terre adoptat actuatum manuale CS11 ad realisandum tri-polaris nexus.

DS5A Interruptor Disiunctivus constat ex tribus polis singulis et actuatore. Unusquisque polus singularis fit ex basi, insulator columnae et parte conductiva. Duo insulatores columnares rotantes sunt installati in basi formantes angulum 50° et dispositi in forma V. Brachia digitorum contactuum et brachia capitum contactuum partis conductivae gladii separatae fixantur ad extremum insulatoris columnaris.

Actuator movet unam partem insulatoris columnaris ad gyrandum, et movet alteram partem insulatoris columnaris ad gyrandum reversim per 90° per rotellam anguli vel levam nexus, ut gladius sit in circumgyratione ad realisandum apertionem et clausuram Interruptoris Disiunctivi. Ruptura insulatoris aperta horizontaliter apparebit in momento clausurae.

Characteristica principalia:

  • Bracchium conductivum factum ex tubis Al-alloy rectangularibus characterizatur fortitudine magna, levi pondere, area radiativa magna et forti resistencia adversus corruptionem.
  • DS5A adhibet particularem aeruginem ad developendum contactum integrum. Punctum contactus est strictum vi elasticitate ipsius contactus. Springa contactus eliminatur ut evitentur possibilia decrementa in vis tenacitatis contactus propter corrosionem et shunting springae, possibilia incrementa caloris et annealing, possibilia incrementa in resistentia contactus, et possibilis vitiosus circulus crescentis caloris vel contactus. Contactus fit ex lamina curva aeruginis, formans magnam aream iunctionis cum bracchio conductivo. In processibus apertionis et clausurae, est brevis cursus frictionis inter contactum et digitum, et vis operativa exigua est. Pars conductiva fuit agnita ab auctoritate competente Sinica ut novum et practicum patentem. (Patent No.: 2103 2 20022.6)
  • Partes rotantes Interruptoris Disiunctivi sunt designatae ut sint liberae a maintenance. Basis rotans est designata in structura clausa quae negat accessum umiditatis, pulveris et gasorum noxiorum, ut cremor lubricans ad bassum temperaturam intra gaudium non defluat vel indurat. Intra basin gaudii sunt gaudium ball thrust et gaudium ball radial, utrumque quod partietur gravitatem et componentem horizontalem Interruptoris Disiunctivi, ut momentum operativum non crescat post longam operationem interruptoris disiunctivi.
  • Bibliotheca Documentorum Rerum
    Restricted
    12 to 800kV Center Vee Center Break Disconnect Switch Installation and Instruction Manuals
    Installation Manual
    English
    Consulting
    Consulting
    FAQ pro
    Q: Quae sunt praecipua consideranda in electione disiunctionum in regionibus altitudinis magna (>3000m)?
    A:

    Correptio altitudinis necessaria est. Puncta principalia includunt:

    • Incrementum distantiæ insulationis externæ: ≥15%

    • Tensio nominata degradata

    • Design contra condensationem mechanicae

    Modellica recommendata:

    • Rockwill: DS27-550/5000

    • Pinggao: GW27-550(W)-H

    • Siemens: 3DN3-550 cum "Kit Altitudinis Alta"

    • Hitachi Energy: DSSP-550 cum insulatoribus creepage extensis

    Cognosce tui fornitori
    Venditio Online
    Ratio praestabilitae tradendae
    Tempus responsionis
    100.0%
    ≤4h
    Brevis Descriptio Societatis
    Locus Operis: 108000m²m² Numerus omnium laborantium: 700+ Summa Annua Exportatio (USD): 150000000
    Locus Operis: 108000m²m²
    Numerus omnium laborantium: 700+
    Summa Annua Exportatio (USD): 150000000
    Servitia
    Genus Negotii: Design/Fabricatio/Venditio
    Categorias Principales: apparatus electrum altum voltus/transformator
    Gubernatio vitae
    Servitia gestionis curae integralis pro quaestu, usu, conservatione et post-venditionem apparatus electricorum, securitatem operationis, continuationem imperii et usum electricitatis sine cura garantia.
    Fornitori instrumentorum praeteritus est certificationem qualificationis platformae et iudicium technicum, ut ex fonte conformitas, professionalitas et fiducia servantur.

Producta Connexa

Cognitio Connexa

  • Accidentia Transformatoris Principalis et Questiones Operationis Gas Luminis
    1. Registri accidentis (XIX Martii, MMXIX)Hora XVI:XIIX die XIX Martii, MMXIX, monitorium background reportavit actionem gas levis transformatoris principis numeri III. Conformiter Codex Operationis Transformatorum Electricitatis (DL/T572-2010), personale operationis et maintenance (O&M) inspectavit statum in situ transformatoris principis numeri III.Confirmatio in situ: Panel non-electricus protectionis WBH transformatoris principis numeri III reportavit actionem gas levis phase B corpus tr
    02/05/2026
  • Culpae et Tractatio Terrae Unipolaris in Lineis Distributionis 10kV
    Characteristica et Instrumenta Detegendi Defectus Terrae Monofasiales1. Characteristica Defectuum Terrae MonofasialiumSigna Centralia Admonitionis:Campanula admonitionis sonat, et lucerna indicativa inscripta „Defectus Terrae in Sectione Omnibus [X] kV [Y]“ accenditur. In systematibus ubi punctum neutrum per bobinam Petersen (bobinam suppressionis arcus) ad terram connectitur, lucerna indicativa „Bobina Petersen Operatur“ etiam accenditur.Indicationes Voltmetri Monitoris Isolationis:Tensio phase
    01/30/2026
  • Modus operationis terre iunctae puncti neutralis pro transformatoribus retis electricitatis 110kV~220kV
    Dispositio modi operis terrae puncti neutralis pro transformatoribus rete electricitatis 110kV~220kV debet exigentias tolerationis insulationis puncti neutralis transformatorum complere, et simul conari ut impedimentum sequentiae nullae stationum transformationis fere immutatum maneat, dum certatur ne impedimentum sequentiae nullae compositum in quocumque puncto raptus circuiti systematis ultra ter impedimentum sequentiae positivae compositum excedat.Pro transformatoribus 220kV et 110kV in novis
    01/29/2026
  • Cur Quare Substationes Lapidem Gravem Calculos et Rupem Fractam Utuntur
    Cur Quare Substationes Utuntur Lapidibus, Gravibus, Piscinis et Saxis Tritis?In stationibus transformationis, instrumenta ut transformatores electricitatis et distributionis, lineae transmissionis, transformatores tensionis, transformatores currentis et commutatores disiunctionis omnia terram exigunt. Praeter terram, nunc profundius explorabimus cur gravia et saxa trita in stationibus transformationis saepe utuntur. Quamquam videantur ordinaria, isti lapides partem criticam iuxtaque functionalem
    01/29/2026
  • Cur autem nucleus transformatoris tantum in uno puncto terram tangere debet Nonne terra multipuncta fidelius est
    Cur ergo nucleus transformatoris terram tangere debet?In operatione, nucleus transformatoris, simul cum structuris, partibus et componentibus metallicis quae fixant nucleum et spiras, in forti campo electrico situs est. Sub influentia huius campi electrici, potentialem relativum altum ad terram comparatum acquirunt. Si nucleus non terra tangitur, differentia potentialis inter nucleum et structuras claudicantes et vas terratum existet, quae possit ad intermitterentiam dismissionem ducere.Praetere
    01/29/2026
  • Intellegere Terram Neutralis Transformatoris
    I. Quid est Punctum Neutrum?In transformatoribus et generatoribus, punctum neutrum est locus specificus in spira ubi absoluta tensio inter hunc locum et singula terminalia externa aequalis est. In diagrammate infra, punctumOrepraesentat punctum neutrum.II. Cur Punctum Neutrum Terrendum Est?Modus connexionis electricae inter punctum neutrum et terram in systemate AC triphasico diciturmodus terrendi puncti neutri. Hic modus directe afficit:Securitatem, fidem et oeconomiciam retelectrici;Selectione
    01/29/2026

Solutiones Relatae

  • Design Solution of 24kV Siccum Aera Insulatum Ring Main Unit
    Combinatio Solidi Insulationis Adiuvantis + Insulationis Aereae Siccae repraesentat directionem pro RMU 24kV. Per requirementa insulationis cum compactitate equilibrata et adiuvante solidum insulationis, testes insulationis sine magnificatione significativa dimensionum inter phasos et inter phasos et terram transigi possunt. Inclusio columnae pole solidificat insulationem pro interruptore vacuo et conductoribus eius coniunctis.Maintinendo spatium phasorum exiens 24kV ad 110mm, intensitas electri
    08/16/2025
  • Optimizatio Design Schematum pro Unitate Circulorum Principalium Aere Insulata 12kV ad Minuendam Probabilitatem Disruptionis Emissionis
    Cum celeri progressus industriae electricitatis, conceptus ecologicus de carbonis minore, energiae servanda, et conservatione ambientis profundissime integratus est in designum et fabricam productorum electricorum pro distributione et generatione electricitatis. Unitas Distributiva Circuli (RMU) est dispositivum electricum clavem in retibus distributionis. Securitas, conservatio ambientis, fides operativa, efficacia energetica, et oeconomia sunt tendentiae inevitabiles in eius progressu. RMUs tr
    08/16/2025
  • Analyse communium problematum in unitatibus principali circuitu isolatis gas 10kV (RMUs)
    Introductio:​​RMUs insulati gaseis 10kV sunt amplissime usitati propter multas suas utilitates, sicut quod sint perfecte clausi, habeant excellentem insulativam qualitatem, non requirant maintenance, sint compacti, et praebent installationem flexibilem et commodam. In hoc stadio, paulatim facti sunt nodus criticus in rete distributionis urbano anulari et iocabuntur partem significativam in systemate distributionis electricitatis. Difficultates in RMUs insulatis gaseis possunt graviter impingere
    08/16/2025
Non invenisti adhuc opportunos fornitoris ut te inveniant Citationem Nunc Accipe
Non invenisti adhuc opportunos fornitoris ut te inveniant
Citationem Nunc Accipe
Inquiry
+86
Click to upload file
Descarica
Obtine Applicatio Commerciale IEE-Business
Utiliza app IEE-Business ad inveniendum apparatus obtinendumque solutiones coniungendum cum peritis et participandum in collaboratione industriale ubique et semper propter totam supportionem tuorum projectorum electricitatis et negotiorum