  • DNRH8 Combined Switch in Energy Storage System
  • DNRH8 Combined Switch in Energy Storage System

Attributa principalia

Marca Switchgear parts
Numerus Modeli Commutator DNRH8 in Systemate Energetico Storaggio
Votum nominatum DC 1500V
currus electricus nominatus 630A
Series DNRH8

Descriptiones productorum a fornitori

Descriptio

Commutator DNRH8 est solutio unica pro commutatione et isolatione oneris DC, apta usque ad 1500 VDC et 630 A. Confectus ut respondeat categoriis utilitatis DC-PV1, DC-PV2, et DC-21B, integrat relays principale et praecargandum in unum corpus compactum, classificatum IP67. Optimum pro systematibus photovoltaicis (PV), systematibus storationis energiae batteriarum (BESS), et applicationibus industrialibus DC, DNRH8 simplificat installationem, minuit errores cabling, et praebet commutationem celerem et fidelem cum protectione subvoltage.

Voltage & Current: DC 1500 V, current operativus 200 A–630 A.

Capacitas Commutationis: Capacitas faciendi/tolerandi 15 kA (0.1 s) / 10 kA (1 s); currentus brevis circuitus conditionalis 100 kA.

Praestatio Arcus: Distantia arcus minima; tempus arcing < 3 ms.

Gradus Protectionis: IP67 (externus); IP20 (internus).

Modi Controlis: Manualis vel controlis remotus 24 V cum selectione auto/manualis.

Modulus Subvoltage: Optiones trip activae/passivae (responsum < 0.5 s, backup perditio potentiae 2 minuta).

Modulus Relais Optionalis: Series JDQMK integra relays principale/praecargandum et resistores.

Tolerantia Ambientalis: –40 °C ad +80 °C (derating supra +60 °C); altitudo usque ad 5000 m cum derating.

Durabilitas: > 10,000 cycles mechanicorum; 400–2000 cycles electricorum.

Parameter Valorem
Voltage Operativum Ratingatum (VDC) 1500 V
Currentus Operativus Ratingatus (A) 200, 225, 250, 275, 325, 400, 500, 630
Voltage Insulationis Ratingatum (Ui) 1500 V
Capacitas Faciendi (Icm) 15 kA
Capacitas Tolerandi (Icw) 15 kA @0.1 s / 10 kA @1 s
Currentus Brevis Circuitus Conditionalis (Iq) 100 kA
Longevitas Electrica (cycles) 400–2000
Longevitas Mechanica (cycles) > 10 000
Methodus Controlis Manualis / Remotus (24 V)
Temperatura Ambientalis –40 °C ad +80 °C (derate >60 °C)
Humiditas ≤ 50% @40 °C; ≤ 90% @20 °C
Altitudo ≤ 2000 m (derate to 5000 m)
Gradus Pollutionis III
Categoria Installationis IV (potentia), III (controlis)
Protectio Ingressus IP20 (internus) / IP67 (externus)
Functiones Optionales Modulus Subvoltage, Modulus Relais

Cognosce tui fornitori
Venditio Online
Ratio praestabilitae tradendae
Tempus responsionis
100.0%
≤4h
Brevis Descriptio Societatis
Locus Operis: 1000m² Numerus omnium laborantium: Summa Annua Exportatio (USD): 300000000
Locus Operis: 1000m²
Numerus omnium laborantium:
Summa Annua Exportatio (USD): 300000000
Servitia
Genus Negotii: Venditio
Categorias Principales: pars componentium/Instrumenta inspectionis/apparatus electrum altum voltus/Apparatus electri bassa tensione/Instrumenta et mensurae/Instrumenta productiva/Ferramentae electricitatis
Gubernatio vitae
Servitia gestionis curae integralis pro quaestu, usu, conservatione et post-venditionem apparatus electricorum, securitatem operationis, continuationem imperii et usum electricitatis sine cura garantia.
Fornitori instrumentorum praeteritus est certificationem qualificationis platformae et iudicium technicum, ut ex fonte conformitas, professionalitas et fiducia servantur.

Producta Connexa

Cognitio Connexa

  • Accidentia Transformatoris Principalis et Questiones Operationis Gas Luminis
    1. Registri accidentis (XIX Martii, MMXIX)Hora XVI:XIIX die XIX Martii, MMXIX, monitorium background reportavit actionem gas levis transformatoris principis numeri III. Conformiter Codex Operationis Transformatorum Electricitatis (DL/T572-2010), personale operationis et maintenance (O&M) inspectavit statum in situ transformatoris principis numeri III.Confirmatio in situ: Panel non-electricus protectionis WBH transformatoris principis numeri III reportavit actionem gas levis phase B corpus tr
    02/05/2026
  • Culpae et Tractatio Terrae Unipolaris in Lineis Distributionis 10kV
    Characteristica et Instrumenta Detegendi Defectus Terrae Monofasiales1. Characteristica Defectuum Terrae MonofasialiumSigna Centralia Admonitionis:Campanula admonitionis sonat, et lucerna indicativa inscripta „Defectus Terrae in Sectione Omnibus [X] kV [Y]“ accenditur. In systematibus ubi punctum neutrum per bobinam Petersen (bobinam suppressionis arcus) ad terram connectitur, lucerna indicativa „Bobina Petersen Operatur“ etiam accenditur.Indicationes Voltmetri Monitoris Isolationis:Tensio phase
    01/30/2026
  • Modus operationis terre iunctae puncti neutralis pro transformatoribus retis electricitatis 110kV~220kV
    Dispositio modi operis terrae puncti neutralis pro transformatoribus rete electricitatis 110kV~220kV debet exigentias tolerationis insulationis puncti neutralis transformatorum complere, et simul conari ut impedimentum sequentiae nullae stationum transformationis fere immutatum maneat, dum certatur ne impedimentum sequentiae nullae compositum in quocumque puncto raptus circuiti systematis ultra ter impedimentum sequentiae positivae compositum excedat.Pro transformatoribus 220kV et 110kV in novis
    01/29/2026
  • Cur Quare Substationes Lapidem Gravem Calculos et Rupem Fractam Utuntur
    Cur Quare Substationes Utuntur Lapidibus, Gravibus, Piscinis et Saxis Tritis?In stationibus transformationis, instrumenta ut transformatores electricitatis et distributionis, lineae transmissionis, transformatores tensionis, transformatores currentis et commutatores disiunctionis omnia terram exigunt. Praeter terram, nunc profundius explorabimus cur gravia et saxa trita in stationibus transformationis saepe utuntur. Quamquam videantur ordinaria, isti lapides partem criticam iuxtaque functionalem
    01/29/2026
  • Cur autem nucleus transformatoris tantum in uno puncto terram tangere debet Nonne terra multipuncta fidelius est
    Cur ergo nucleus transformatoris terram tangere debet?In operatione, nucleus transformatoris, simul cum structuris, partibus et componentibus metallicis quae fixant nucleum et spiras, in forti campo electrico situs est. Sub influentia huius campi electrici, potentialem relativum altum ad terram comparatum acquirunt. Si nucleus non terra tangitur, differentia potentialis inter nucleum et structuras claudicantes et vas terratum existet, quae possit ad intermitterentiam dismissionem ducere.Praetere
    01/29/2026
  • Intellegere Terram Neutralis Transformatoris
    I. Quid est Punctum Neutrum?In transformatoribus et generatoribus, punctum neutrum est locus specificus in spira ubi absoluta tensio inter hunc locum et singula terminalia externa aequalis est. In diagrammate infra, punctumOrepraesentat punctum neutrum.II. Cur Punctum Neutrum Terrendum Est?Modus connexionis electricae inter punctum neutrum et terram in systemate AC triphasico diciturmodus terrendi puncti neutri. Hic modus directe afficit:Securitatem, fidem et oeconomiciam retelectrici;Selectione
    01/29/2026
Non invenisti adhuc opportunos fornitoris ut te inveniant Citationem Nunc Accipe
Non invenisti adhuc opportunos fornitoris ut te inveniant
Citationem Nunc Accipe
Inquiry
+86
Click to upload file
Descarica
Obtine Applicatio Commerciale IEE-Business
Utiliza app IEE-Business ad inveniendum apparatus obtinendumque solutiones coniungendum cum peritis et participandum in collaboratione industriale ubique et semper propter totam supportionem tuorum projectorum electricitatis et negotiorum