DNESS2 Fusus pro protectionem bateriarum et systematum bateriarum

  • DNESS2 Fuse for battery and battery system Protection
  • DNESS2 Fuse for battery and battery system Protection
  • DNESS2 Fuse for battery and battery system Protection
  • DNESS2 Fuse for battery and battery system Protection
  • DNESS2 Fuse for battery and battery system Protection

Attributa principalia

Marca Switchgear parts
Numerus Modeli DNESS2 Fusus pro protectionem bateriarum et systematum bateriarum
Votum nominatum DC 1500V
currus electricus nominatus 100-630A
Capacitas disiuncionis 250kA
Series DNESS2-S8J/S8L/S8N/S8Q/S8R

Descriptiones productorum a fornitori

Descriptio
Ambitus humectitatis operativi: Ad temperaturam maximam de 40℃, humiditas relativa non excedat 50%. Ad temperaturam maximam de 20℃, humiditas relativa non debet
excedere 90%.
Ambitus normalis temperature operativae: -5℃ ad 40℃. Ambitus permissibilis temperature: -40℃ ad 80℃.
Altitudo: non plus quam 2000m. Quando altitudo hoc valorem excedit:
Temperatura fusoris aucta est circa 0.5k pro singulis 100 metris supra mare.
Pro singulis 100 metris incrementi altitudinis, temperatura ambientis diminuitur in mediam circa 0.5 ℃.
Sub conditionibus normalibus, fusores usi in spatiis apertis possunt negligere effectum altitudinis super currentem nominalem et adhuc eligi secundum conditiones standard.
Fusores usi in spatiis clausis, si temperatura aeris ambientis in capsula vel in capsula non diminuit significanter cum altitudine, atque adhuc potest attingere plus quam 40℃, necessarium est reducere capacitatem currentis nominalem. Formula electionis currentis nominalem fusoris
Specifcatio et modello magnitudo Tensio nominale V Currents nominale A Capacitas interruptiva nominale kA
DNESS2-S8J/S8L/S8N/S8Q/S8R - 100 2 DC 1500V 100 250kA
DNESS2-S8J/S8L/S8N/S8Q/S8R - 125 2 DC 1500V 125 250kA
DNESS2-S8J/S8L/S8N/S8Q/S8R - 160 2 DC 1500V 160 250kA
DNESS2-S8J/S8L/S8N/S8Q/S8R - 200 2 DC 1500V 200 250kA
DNESS2-S8J/S8L/S8N/S8Q/S8R - 250 2 DC 1500V 250 250kA
DNESS2-S8J/S8L/S8N/S8Q/S8R - 315 2 DC 1500V 315 250kA
DNESS2-S8J/S8L/S8N/S8Q/S8R - 350 2 DC 1500V 350 250kA
DNESS2-S8J/S8L/S8N/S8Q/S8R - 400 2 DC 1500V 400 250kA
DNESS2-S8J/S8L/S8N/S8Q/S8R - 450 2 DC 1500V 450 250kA
DNESS2-S8J/S8L/S8N/S8Q/S8R - 500 2 DC 1500V 500 250kA
DNESS2-S8J/S8L/S8N/S8Q/S8R - 550 2 DC 1500V 550 250kA
DNESS2-S8J/S8L/S8N/S8Q/S8R - 630 2 DC 1500V 630 250kA
Cognosce tui fornitori
Venditio Online
Ratio praestabilitae tradendae
Tempus responsionis
100.0%
≤4h
Brevis Descriptio Societatis
Locus Operis: 1000m² Numerus omnium laborantium: Summa Annua Exportatio (USD): 300000000
Locus Operis: 1000m²
Numerus omnium laborantium:
Summa Annua Exportatio (USD): 300000000
Servitia
Genus Negotii: Venditio
Categorias Principales: pars componentium/Instrumenta inspectionis/apparatus electrum altum voltus/Apparatus electri bassa tensione/Instrumenta et mensurae/Instrumenta productiva/Ferramentae electricitatis
Gubernatio vitae
Servitia gestionis curae integralis pro quaestu, usu, conservatione et post-venditionem apparatus electricorum, securitatem operationis, continuationem imperii et usum electricitatis sine cura garantia.
Fornitori instrumentorum praeteritus est certificationem qualificationis platformae et iudicium technicum, ut ex fonte conformitas, professionalitas et fiducia servantur.

Producta Connexa

Cognitio Connexa

  • Culpae et Tractatio Terrae Unipolaris in Lineis Distributionis 10kV
    Characteristica et Instrumenta Detegendi Defectus Terrae Monofasiales1. Characteristica Defectuum Terrae MonofasialiumSigna Centralia Admonitionis:Campanula admonitionis sonat, et lucerna indicativa inscripta „Defectus Terrae in Sectione Omnibus [X] kV [Y]“ accenditur. In systematibus ubi punctum neutrum per bobinam Petersen (bobinam suppressionis arcus) ad terram connectitur, lucerna indicativa „Bobina Petersen Operatur“ etiam accenditur.Indicationes Voltmetri Monitoris Isolationis:Tensio phase
    01/30/2026
  • Modus operationis terre iunctae puncti neutralis pro transformatoribus retis electricitatis 110kV~220kV
    Dispositio modi operis terrae puncti neutralis pro transformatoribus rete electricitatis 110kV~220kV debet exigentias tolerationis insulationis puncti neutralis transformatorum complere, et simul conari ut impedimentum sequentiae nullae stationum transformationis fere immutatum maneat, dum certatur ne impedimentum sequentiae nullae compositum in quocumque puncto raptus circuiti systematis ultra ter impedimentum sequentiae positivae compositum excedat.Pro transformatoribus 220kV et 110kV in novis
    01/29/2026
  • Cur Quare Substationes Lapidem Gravem Calculos et Rupem Fractam Utuntur
    Cur Quare Substationes Utuntur Lapidibus, Gravibus, Piscinis et Saxis Tritis?In stationibus transformationis, instrumenta ut transformatores electricitatis et distributionis, lineae transmissionis, transformatores tensionis, transformatores currentis et commutatores disiunctionis omnia terram exigunt. Praeter terram, nunc profundius explorabimus cur gravia et saxa trita in stationibus transformationis saepe utuntur. Quamquam videantur ordinaria, isti lapides partem criticam iuxtaque functionalem
    01/29/2026
  • Cur autem nucleus transformatoris tantum in uno puncto terram tangere debet Nonne terra multipuncta fidelius est
    Cur ergo nucleus transformatoris terram tangere debet?In operatione, nucleus transformatoris, simul cum structuris, partibus et componentibus metallicis quae fixant nucleum et spiras, in forti campo electrico situs est. Sub influentia huius campi electrici, potentialem relativum altum ad terram comparatum acquirunt. Si nucleus non terra tangitur, differentia potentialis inter nucleum et structuras claudicantes et vas terratum existet, quae possit ad intermitterentiam dismissionem ducere.Praetere
    01/29/2026
  • Intellegere Terram Neutralis Transformatoris
    I. Quid est Punctum Neutrum?In transformatoribus et generatoribus, punctum neutrum est locus specificus in spira ubi absoluta tensio inter hunc locum et singula terminalia externa aequalis est. In diagrammate infra, punctumOrepraesentat punctum neutrum.II. Cur Punctum Neutrum Terrendum Est?Modus connexionis electricae inter punctum neutrum et terram in systemate AC triphasico diciturmodus terrendi puncti neutri. Hic modus directe afficit:Securitatem, fidem et oeconomiciam retelectrici;Selectione
    01/29/2026
  • Quid est Differentia Inter Transformatores Rectificatores et Transformatores Potentiae?
    Quid est transformator rectificans?"Conversio potentiae" est terminus generalis qui conversionem, inversionem et conversionem frequentiae comprehendit, inter quas conversio praecipue usitatissima est. Apparatus rectificans convertit potentiam AC input in DC output per rectificationem et filtrationem. Transformator rectificans servit ut transformator alimentationis pro talibus apparatibus rectificantibus. In applicationibus industrialibus, plerumque alimenta DC obtinentur per combinandum transfor
    01/29/2026
Non invenisti adhuc opportunos fornitoris ut te inveniant Citationem Nunc Accipe
Non invenisti adhuc opportunos fornitoris ut te inveniant
Citationem Nunc Accipe
Inquiry
+86
Click to upload file
Descarica
Obtine Applicatio Commerciale IEE-Business
Utiliza app IEE-Business ad inveniendum apparatus obtinendumque solutiones coniungendum cum peritis et participandum in collaboratione industriale ubique et semper propter totam supportionem tuorum projectorum electricitatis et negotiorum