Meter Horarum DC in Rail DIN

  • Din-Rail DC Watt Hour Meter
  • Din-Rail DC Watt Hour Meter

Attributa principalia

Marca Wone
Numerus Modeli Meter Horarum DC in Rail DIN
Votum nominatum DC1kv
currus electricus nominatus 2000A
Frequenta nominata 50(Hz)
Modus communicandi RS485
Series DEM2D002

Descriptiones productorum a fornitori

Descriptio

Descripio

Montatus in rail DIN, adoptat material PC retardant flammam, resistens impactui et intemperiae, et aptus pro variis ambientibus installationis. Metrum DC habet functionem tariffae, chip horologii integratum. Error horologii accuratia 0.5s/dies quod garantit fidebilitatem functionis tariffae.

Characteristicae

  • Communicatio RS485: usata pro configuratione parametri, lectura datarum; protocollo DTL645/Modbus Protocal.

  • Metrorum DC: usans sampling shunt, accuratia mensurae alta; potest mensurare potentiam DC, currentem, tensionem.

  • Functio alarmatis: Alarma supercurrentis: Quando currentis excedit valorem CT1 statutum ab metro, evenit eventus alarmatis, et lucerna alarmatis in superficie paneli electrico illuminatur (lucerna lutea), Simul, valor registri status alarmatis mutabitur, et usator potest legere hunc registrum per communicationem ut determinet si alarma supercurrentis occurrerit.

  • Display: LCD cum lumine retro, Supportans varia parametri display, data energiae et parametri instantanei.

  • Una via relais out put (Usata pro interrupcio supercurrentis).

  • Upgrade firmware: Upgrade local RS485.

Specificationes


Principale
Amplitudo DEM
Numerus Modeli DEM2D002D114071-HPLCD114071-HPLCvHPLCD114071-HPLC D114071-HPLCD114071-HPLC 
Typus Producti vel Componentis Metra energiae
Patria originis China


Complementaria
Phasus Unus Phasus
Applicatio Dispositivi Rail DIN
Gradus accurate Classis 1.0 energiae activae IEC 62053-41
Accurate currentis 0.5%
Accurate tensionis 0.5%
Accurate potentiae activae 1.0%
Tensio nominata DC 5V~1000V
Supply auxiliaris 85~300V AC vel 85-300V DC
Frequencia rete 50Hz
Currentis Methodus connectionis shunt, latus primarium

 currentis supportat usque ad 2000A

Signal connectionis :75mV

Constantia pulsus 1000imp/kWh,

1.2 vice maxima tensio et currentis,

latitudo pulsus est 1.2ms, correspondens ad setting currentis

Tensio sustinendi AC 4400V/min
Tensio sustinendi impulsus 6.4kV - 1.2/50µS forma undarum
Consumptio potenti ≤8VA  ≤0.4W
Typus technologiae Electronicus
Typus display LCD6+2
Protocollo portus communicationis DTL645
Support portus communicationis RS485/Modbus
Normae IEC 62053-41
Ambientis
Temperatura aeris ambientis pro operatione -25~70℃
Temperatura aeris ambientis pro storatione -25-70℃
Humiditas relativa ≤95%


Diagramma Connectionis

image.png












Cognosce tui fornitori
Venditio Online
Ratio praestabilitae tradendae
Tempus responsionis
100.0%
≤4h
Brevis Descriptio Societatis
Locus Operis: 65666m²m² Numerus omnium laborantium: 300+ Summa Annua Exportatio (USD): 50000000
Locus Operis: 65666m²m²
Numerus omnium laborantium: 300+
Summa Annua Exportatio (USD): 50000000
Servitia
Genus Negotii: Design/Fabricatio/Venditio
Categorias Principales: cable et filum/Energia nova/Instrumenta inspectionis/apparatus electrum altum voltus/Aedificii electritas Apparatus electricus/Apparatus electri bassa tensione/Instrumenta et mensurae/Instrumenta productiva/aestus apparatus/Ferramentae electricitatis
Gubernatio vitae
Servitia gestionis curae integralis pro quaestu, usu, conservatione et post-venditionem apparatus electricorum, securitatem operationis, continuationem imperii et usum electricitatis sine cura garantia.
Fornitori instrumentorum praeteritus est certificationem qualificationis platformae et iudicium technicum, ut ex fonte conformitas, professionalitas et fiducia servantur.

Producta Connexa

Cognitio Connexa

  • Accidentia Transformatoris Principalis et Questiones Operationis Gas Luminis
    1. Registri accidentis (XIX Martii, MMXIX)Hora XVI:XIIX die XIX Martii, MMXIX, monitorium background reportavit actionem gas levis transformatoris principis numeri III. Conformiter Codex Operationis Transformatorum Electricitatis (DL/T572-2010), personale operationis et maintenance (O&M) inspectavit statum in situ transformatoris principis numeri III.Confirmatio in situ: Panel non-electricus protectionis WBH transformatoris principis numeri III reportavit actionem gas levis phase B corpus tr
    02/05/2026
  • Culpae et Tractatio Terrae Unipolaris in Lineis Distributionis 10kV
    Characteristica et Instrumenta Detegendi Defectus Terrae Monofasiales1. Characteristica Defectuum Terrae MonofasialiumSigna Centralia Admonitionis:Campanula admonitionis sonat, et lucerna indicativa inscripta „Defectus Terrae in Sectione Omnibus [X] kV [Y]“ accenditur. In systematibus ubi punctum neutrum per bobinam Petersen (bobinam suppressionis arcus) ad terram connectitur, lucerna indicativa „Bobina Petersen Operatur“ etiam accenditur.Indicationes Voltmetri Monitoris Isolationis:Tensio phase
    01/30/2026
  • Modus operationis terre iunctae puncti neutralis pro transformatoribus retis electricitatis 110kV~220kV
    Dispositio modi operis terrae puncti neutralis pro transformatoribus rete electricitatis 110kV~220kV debet exigentias tolerationis insulationis puncti neutralis transformatorum complere, et simul conari ut impedimentum sequentiae nullae stationum transformationis fere immutatum maneat, dum certatur ne impedimentum sequentiae nullae compositum in quocumque puncto raptus circuiti systematis ultra ter impedimentum sequentiae positivae compositum excedat.Pro transformatoribus 220kV et 110kV in novis
    01/29/2026
  • Cur Quare Substationes Lapidem Gravem Calculos et Rupem Fractam Utuntur
    Cur Quare Substationes Utuntur Lapidibus, Gravibus, Piscinis et Saxis Tritis?In stationibus transformationis, instrumenta ut transformatores electricitatis et distributionis, lineae transmissionis, transformatores tensionis, transformatores currentis et commutatores disiunctionis omnia terram exigunt. Praeter terram, nunc profundius explorabimus cur gravia et saxa trita in stationibus transformationis saepe utuntur. Quamquam videantur ordinaria, isti lapides partem criticam iuxtaque functionalem
    01/29/2026
  • Cur autem nucleus transformatoris tantum in uno puncto terram tangere debet Nonne terra multipuncta fidelius est
    Cur ergo nucleus transformatoris terram tangere debet?In operatione, nucleus transformatoris, simul cum structuris, partibus et componentibus metallicis quae fixant nucleum et spiras, in forti campo electrico situs est. Sub influentia huius campi electrici, potentialem relativum altum ad terram comparatum acquirunt. Si nucleus non terra tangitur, differentia potentialis inter nucleum et structuras claudicantes et vas terratum existet, quae possit ad intermitterentiam dismissionem ducere.Praetere
    01/29/2026
  • Intellegere Terram Neutralis Transformatoris
    I. Quid est Punctum Neutrum?In transformatoribus et generatoribus, punctum neutrum est locus specificus in spira ubi absoluta tensio inter hunc locum et singula terminalia externa aequalis est. In diagrammate infra, punctumOrepraesentat punctum neutrum.II. Cur Punctum Neutrum Terrendum Est?Modus connexionis electricae inter punctum neutrum et terram in systemate AC triphasico diciturmodus terrendi puncti neutri. Hic modus directe afficit:Securitatem, fidem et oeconomiciam retelectrici;Selectione
    01/29/2026
Non invenisti adhuc opportunos fornitoris ut te inveniant Citationem Nunc Accipe
Non invenisti adhuc opportunos fornitoris ut te inveniant
Citationem Nunc Accipe
Inquiry
+86
Click to upload file
Descarica
Obtine Applicatio Commerciale IEE-Business
Utiliza app IEE-Business ad inveniendum apparatus obtinendumque solutiones coniungendum cum peritis et participandum in collaboratione industriale ubique et semper propter totam supportionem tuorum projectorum electricitatis et negotiorum