• Iron shell type Intelligent dehumidifier
  • Iron shell type Intelligent dehumidifier
  • Iron shell type Intelligent dehumidifier
  • Iron shell type Intelligent dehumidifier
Iron shell type Intelligent dehumidifier
$41.00
Model
ZCS21M1 60W
ZCS21M2 60W
ZCS21M1 30W
ZCS21M2 30W
ZCS21M1 20W
ZCS21M2 20W
Basic info
Brand Wone Store
Model NO. Iron shell type Intelligent dehumidifier
Rated voltage AC220V+10%
Rated frequency 50/60Hz
Communication port support RS485/RF
Rated power 60W
cabinet type iron plate
Series ZCS21M1/M2
Product Detail

The semiconductor dehumidifier for switchgear is a reliable assistant to safeguard the stable operation of the switchgear, focusing on dealing with the problem of humidity inside the cabinet. In the power system, due to factors such as high environmental humidity and large temperature differences between day and night, the switchgear is prone to condensation inside. Excessive water vapor not only accelerates the corrosion and aging of electrical components, reduces insulation performance, but in severe cases, it may also cause short - circuit faults, threatening the safety and stability of power supply. This dehumidifier uses semiconductor refrigeration technology and operates based on the Peltier effect. The semiconductor refrigeration sheet inside, when powered on, cools rapidly on one side and heats up on the other side. When the humid air inside the switchgear is sucked into the dehumidification air duct by the fan and comes into contact with the cooling surface, the water vapor immediately condenses into liquid water upon cooling and drains out of the cabinet along the water guide pipe. The air passing through the heating surface has a slightly increased temperature and returns to the cabinet in a dry state, avoiding negative impacts caused by temperature differences. The semiconductor dehumidifier for switchgear has multiple practical features. It has low energy consumption, is energy - saving and environmentally friendly, and effectively reduces operating costs. It is small in size, light in weight, and easy to install, and can be flexibly adapted to the spatial layouts of various switchgears. At the same time, some products are equipped with high - precision humidity sensors and intelligent control systems, which can accurately monitor the humidity inside the cabinet in real - time. Once the humidity exceeds the preset safe range, the dehumidification operation is automatically started, and when the humidity reaches the standard, it stops automatically, achieving intelligent and unattended high - efficiency dehumidification, and creating a dry and stable operating environment for the switchgear in all aspects. All series come with a communication function and can be connected to the background monitoring system through the RS485 interface. Maintenance personnel can remotely and real - time monitor the operating status of the dehumidifier and the humidity data inside the cabinet, which is convenient for timely fault diagnosis and maintenance management, further improving the intelligence level and safety of power equipment operation and maintenance.

Know your supplier
Wone Store
Main Categories
High voltage/Low voltage/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment/Instrument Transformer/Equipment Parts
Business Type
Sales
Highest Annual Export (USD)
$300000000
Professional Experience
1 years
Workplace
1000m²
占位
占位
Documents
Restricted.
ZCS Series Intelligent dehumidifier series
White paper English
Consulting
Related Products
Related Knowledges
What are the typical connection methods for 35kV distribution lines?
What are the typical connection methods for 35kV distribution lines?
Typical Wiring Diagram of 35kV Line Radial π ConnectionWhen a 35kV line adopts a radial power grid structure, a single - side power supply or a double - side power supply radial type can be used according to the situation of the power supply points, and a loop - out interval is reserved at the end of the line.Typical Wiring Diagram of 35kV Line Radial T - ConnectionFor double - radial lines, it is advisable to select a double - side power supply. When the power supply points do not meet the r
Leon
07/18/2025
Why are the ground fault point and the accident point not at the same location?
Why are the ground fault point and the accident point not at the same location?
Fault Transfer VoltageIn low - voltage distribution systems, there is a type of personal electric shock accident where the accident occurrence point and the system fault point are not at the same location. This kind of accident occurs because after a ground fault happens elsewhere, the generated fault voltage is conducted to the metal casings of other equipment through the PE wire or PEN wire. When the fault voltage on the metal casing of the equipment is higher than the human - body safe voltag
Leon
07/18/2025
Analysis of Transformer Capacity, Load Rate and Number of Units Selection Issues
Analysis of Transformer Capacity, Load Rate and Number of Units Selection Issues
The safe and economical operation of power transformers is related to the safety, economy, stability, and reliability of the operations of various industries. The limitations of conditions such as the investment economic indicators for its selection, the economic benefits of maintenance and operation, and the adaptability in the new environment (access of distributed power sources, configuration of energy storage, etc.) make it impossible to include comprehensive factors in other aspects.The cap
Leon
07/17/2025
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
1 IntroductionLow - voltage current transformers for metering, with a through - core type epoxy resin structure, are widely used in distribution transformer areas and for small - to - medium - sized industrial and commercial electricity consumption. As a range expander for electric energy metering, their performance directly relates to electricity consumption safety and the accuracy of users' trade calculations. Studying long - term immersion's impact on these transformers is practically signifi
Felix Spark
07/17/2025
What is reactive power measurement?
What is reactive power measurement?
The power which exists in the circuit when the voltage and current are out of phase to each other, such type of power is known as the reactive power. The formula measures the reactive power in the circuitReactive Power Measurement & VarmetersReactive power measurement is critical as it indicates circuit power loss: low reactive power worsens load power factor, increasing system losses. Varmeters (volt-ampere reactive meters) measure reactive power and are categorized by circuit phases:Single
Edwiin
07/17/2025
How to Design and Install a Solar PV System?
How to Design and Install a Solar PV System?
Design and Installation of Solar PV SystemsModern society relies on energy for daily needs like industry, heating, transport, and agriculture, mostly met by non-renewable sources (coal, oil, gas). However, these cause environmental harm, are unevenly distributed, and face price volatility due to limited reserves—driving demand for renewable energy.Solar energy, abundant and capable of meeting global needs, stands out. Standalone PV systems (Fig 1) offer energy independence from utilities.
Edwiin
07/17/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!