• MC Series Flexible Cable For Coal-mining
  • MC Series Flexible Cable For Coal-mining
MC Series Flexible Cable For Coal-mining
discuss personally
Model
TYPE A MC-0.38/0.66
Basic info
Brand Wone
Model NO. MC Series Flexible Cable For Coal-mining
Rated voltage 0.38/0.66kV
number of core 3+1+3-core
alloy code TU2
Series MC
Product Detail

Application

It is suitable for rated voltage Uo/U 1.9/3.3KV coalmining machine and the similar equipments.

Application conditions

The long-term permissible working temperature of cable conductor for rated voltage up to and including 0.38/0.66kV is 90 ,Black jacket.

The long-term permissible working temperature of cable conductor for rated voltage up to and including 0.66/1.44kV is 90 ,Yellow jacket . and that of the cable conductor of rated voltage1.9/3.3kV is 90℃ It’s smallest bending radiusis 6 times than the size of cable diameter. The yellow sheathed cables can’t be exposed in the sun for a long time.

Model and names

用途.png

Structure diagram

结构.png

Specification size

Rated voltage 0.66/1.14kV cable dimensions

规格.png

Rated voltage 0.38/0.66kV cable dimensions

规格2.png

 Rated voltage 1.9/3.3kV cable dimensions

规格3.png

Technical parameter

Finished DC resistance

 技术特性1.png

Finished insulation resistance

技术特性2.png

    a. Conductor temperature of  90℃ to allow work;

    b. it has the anti-bending characteristics;

    c. it has the anti-extrusion and anti-pressure characteristics;

    d. Insulation tensile strength greater than 6.5Mpa, more than 200% elongation;

    e. Max anti-bending 11.0 N/mm2, Max anti-tensible force>250%;

    f. No damage under rated voltage 0.38/0.66kV for 3.0kV/5min,0.66/1.14kV for 3.7kV/5min, 1.9/3.3kV for 6.8kV/0.5min respectively;

    g. It complies with fire-proof feature based on MT386-1995.


Q: What is MC cable? 

A: MC Cable is Metal Clad Cable. It consists of a combination of insulated wires and is covered with a metal sheath. This cable has good mechanical protection performance and can resist external physical damage such as extrusion and collision to a certain extent. 

Q: What are the main application scenarios of MC cables? 

A: MC cable is often used in commercial buildings, industrial facilities, mining sites and other places. In commercial buildings, such as shopping malls, office buildings, etc., it can be used for electrical wiring systems to power lighting, sockets and other equipment. In industrial facilities, such as factory floors, due to the complex environment, the metal sheathing of MC cables can provide additional protection and is suitable for connecting power to various types of machines and equipment. Because of its excellent defensive performance, it is often used in mining, metallurgy and other fields. 

Q: What are the advantages of MC cable? 

A: Its advantages include high safety, metal sheath can be used as a grounding path; The installation is relatively flexible, and can be laid under a variety of ways such as bridge and cable trough. And has a good electromagnetic compatibility, can reduce the electromagnetic interference to the surrounding equipment.



Know your supplier
Wone
Main Categories
High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$50,000,000
Professional Experience
1 years
Workplace
65666m²m²
占位
占位
Related Products
Related Knowledges
Research and Application of Communication Security Strategies for Smart Meters
Research and Application of Communication Security Strategies for Smart Meters
1. Security Threats Facing Smart Meter Communications1.1 Physical Layer Security ThreatsPhysical layer security threats refer to factors that damage or interfere with the hardware devices and physical connections of smart meters, directly affecting their normal operation and data transmission. From the perspective of equipment damage, harsh natural environments such as lightning strikes, floods, and earthquakes can directly destroy the hardware circuits and structures of smart meters, rendering
Echo
09/01/2025
Analysis of Issues and Causes in Smart Meter Testing
Analysis of Issues and Causes in Smart Meter Testing
1. Issues and Cause Analysis in Smart Electricity Meter TestingDuring the verification of smart electricity meters, inspections must be conducted on the meter’s appearance, as well as the clarity and integrity of nameplate markings. Additionally, careful checks are required for physical damage and whether the display can show digits completely. A power-on inspection is also necessary. If error codes appear on the display after power-up, faults should be identified and addressed according to the
Oliver Watts
09/01/2025
Analysis of Common Operational Fault Causes in Smart Electricity Meters
Analysis of Common Operational Fault Causes in Smart Electricity Meters
With the continuous development of smart grids, smart electricity meters are being increasingly widely applied, and various types of operational faults in smart meters are frequently encountered in energy measurement work. This paper analyzes the causes of smart meter failures and proposes corresponding solutions, using several actual operational fault cases as examples.1. Black ScreenA black screen refers to a powered meter with no display, which is the most commonly occurring fault in field-op
Felix Spark
09/01/2025
What tests are required for a qualified smart electricity meter?
What tests are required for a qualified smart electricity meter?
In today's world, not wearing a watch is no longer unusual, but not having an electricity meter is a serious issue. As a measuring instrument vital to people's daily lives, the electricity meter is an essential tool for power consumption measurement and billing in every household. According to current national strategic requirements for smart grid development, smart electricity meters have been widely applied and promoted, bringing entirely new and extensive market opportunities to the metering
Oliver Watts
09/01/2025
Discussion on Fault Diagnosis and Handling Technologies for Smart Meters in Electricity Inspections
Discussion on Fault Diagnosis and Handling Technologies for Smart Meters in Electricity Inspections
1 Analysis of Smart Meter Faults and Their Impact on the Power Grid1.1 Introduction to Smart Meter Functions and Their Critical Role in Modern Power GridsSmart meters exchange data in real time with power companies through two-way communication, enabling functions such as remote meter reading and dynamic tariff adjustment. This capability allows users to adjust their consumption based on real-time pricing, achieving energy savings and cost reduction. Meanwhile, smart meters support grid automati
Felix Spark
09/01/2025
Analysis of the Integrated Application of Smart Meters and Meter Reading, Verification, and Billing Information Systems
Analysis of the Integrated Application of Smart Meters and Meter Reading, Verification, and Billing Information Systems
Meter reading, verification, and billing are critical operations for power companies, and their efficiency directly impacts the company's sustainable development. In recent years, with the widespread adoption of intelligent technologies, smart meters have been promoted and applied in power companies, driving transformation in meter reading and billing operations. The integrated application of smart meters and meter reading, verification, and billing information systems has become a key developme
Echo
09/01/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.