• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


Tres-phase 11kV 22kV grounding/earthing transformers

  • Customization Three - phase 11kV 20kV 22kV 30kV grounding/earthing transformers Original Manufacturer
  • Customization Three - phase 11kV 20kV 22kV 30kV grounding/earthing transformers Original Manufacturer

Attributa principalia

Marca ROCKWILL
Numerus Modeli Tres-phase 11kV 22kV grounding/earthing transformers
Votum nominatum 22kV
Frequenta nominata 50/60Hz
Series JDS

Descriptiones productorum a fornitori

Descriptio

Descriptio

Hoc transformator terrae triphasus 11kV/22kV confectus est pro rete electrico medio tensionis. Per creationem puncti neutralis artificialis, accurate functionem protectionis terrae adimplet et ad varias conditiones systematis distributionis idoneus est. Cum vitiis terrae uniphasis obviam ire debet, efficaciter eas tractat, munit solidam defensionem pro stabili operatione retium urbanorum et installationum electricarum industrialium, et certam alimentationem electricam systematis assecurat.

Characteristica

  • Adaptatio Tensionis Flexibilis: Sustinet systemata tensionis 11kV et 22kV, accurate congruit specificationibus communium retium medii tensionis, latissime adaptatur diversis conditionibus applicationis electricarum, et habet fortis compatibilitatem.

  • Gestio Intelligentis Vitiis: Cum vitiis uniphasis obviam ire debet, celeriter suppressit overvoltages arc-grounding, multum minuit currentes vitiis, minuit periculum detrimenti instrumentorum electricorum, et meliorat efficientiam operationis et maintenance systematis.

  • Structura Fiducia et Robusta: Adoptat nucleos ferreos qualitatis, involutions durabiles, et coniuncta cum carcasse robusta. Effectiviter resistit erosioni ambientes duras sicut humiditas et pulvis, assecurat operationem stabilam longinqua temporis instrumentorum, et minuit costus maintenance.

  • Assecuratio Completalis Securitatis: Stabiliter praebet terram puncti neutralis, praevenit fluctuationes tensionis et vitiis insulationis ab origine, tutat securitatem retis electrici et instrumentorum electricorum associatorum, et fundat fundamentum solidum pro securitate systematis electrici.

Parametri Technici Principales

FAQ pro
Q: Quae est functio impedentiae secundae ordinis transformatoris terrae et qualis est eius communis ambitus
A:

Impedance zero-sequens est parameter clavis qui determinat magnitudinem currentis fault terreni, directe affectans sensibilitatem et fiduciam protectionis relais. Functio eius est "accurate controlare amplitudinem currentis fault" — assecurans ut currentis fault sit satis magnus ad actionem protectionis triggerando, dum evitatur currentis excessivus qui fortasse damnet instrumenta.

Impedance zero-sequens solitus est calibrari in "ohms per phasim", cum ambitu vulgari de 10-50 ohms per phasim (valor specificus oportet customizari secundum methodum systematis grounding et requisitiones protectionis). Exempli gratia, systemata low-current grounding oportet electere impedimentum maius (30-50 ohms) ad limitandum currentem fault, dum systemata high-current grounding electunt impedimentum minus (10-20 ohms) ad assecurandum operationem fidelem protectionis. Parameter iste debet conformari specificationibus testis et marking IEE-Business 32 et IEC 60076-8.
Q: Quae sunt normae pro "tempore tolerantia defectus" transformatorum terrae/terrae, et quomodo ea adiungere in selectione?
A:

Tempus tolerabile faultis refertur ad maximam temporalem periodum, qua transformator earthing/grounding potest sustinere calores et stressus mechanicorum, qui a currente faulti generantur, sine damno sub capacitate brevi tempore nominata. Hoc est basis principalis pro designo insulatorio et structurali. Standardes IEEE 32 et IEC 60076-5 specificant quattuor genera durationum standardarum: ① 10 secundae: convenit systematis protectionis celeris (sicut differentialis per fibram opticam), ubi faulta possunt isolari intra 10 secundas; ② 30 secundae: nivellus tolerabilis mainstream, conveniens tempori actionis protectionis relays maioris partis distributionum reticulorum et transmissionum; ③ 60 secundae: utitur in systematibus vetustis aut reticulis electricis complicatis, ubi tempus actionis protectionis longius est; ④ 1 hora: solum applicatur ad systemata grounding cum resistencia alta, ubi currentis faulti parvus est, sed necessaria est observatio longa.

In selectione, principium "tempus tolerabile ≥ tempus actionis protectionis + redundancia dispositionis faulti" sequi debet. Exempli gratia, in systemate 110kV, quod usum facit protectionis overcurrentis communis, tempus actionis protectionis circa 15 secundas est, et productum cum nivello tolerabili 30 secundarum debet eligi, ut evitetur combustio apparatus propter insufficiens tempus tolerabile.
Q: Quid significat "capacitas brevis temporis" transformatoris terrestris et quomodo determinari potest eius capacitas nominata?
A:

"Capacitas brevi temporis" est indicium praecipuum performance transformatorum earthing/grounding, quod refert ad eorum facultatem perferendi maximum currentem fault terrae intra tempus specificatum (sicut 30 secundorum). Hoc determinatur ex eorum characteribus operationis "brevi temporis operatione in casu vitii et levi onere aut nullo onere in operatione normali".

Capacitas nominata debet calculari per formulam: kVA=3×V×I, ubi V est voltus phase systematis et I est maximus currentus fault terrae. Exempli gratia, pro systemate 110kV (voltus phase circa 63.5kV), si maximus currentus fault terrae est 100A, capacitas brevis temporis 30 secundorum est 3×63.5×100≈19050kVA (19.05MVA).
Niveles capacitatis standard industriae dividuntur in duas categorias: parvam capacitatem a bassa et media tensione (25kVA, 50kVA, 100kVA…1000kVA) et magnam capacitatem a alta tensione (1MVA, 2.5MVA…50MVA), inter quas level 50MVA principaliter utitur in magnis systematibus transmissionis extra alti tensio.
Q: Quae est amplitudo tensionis transformatorum terrae/praefixi et quomodo modellos iuxta tensionem systematis seligere?
A:

<meta />

Nivellus tensionis transformatoris terrae/grounding est perfecte congruens cum tensione lineae systematis electricitatis coniuncti, ab medio voltage, alto voltage usque ad extra altum voltage. Principia specifica et selectiva sunt haec:
  • Amplitudo nivelli tensionis: Medio Voltage (MV) 3.3kV-44kV (communiter 3.3kV, 6kV, 11kV, 15kV, 33kV), Alto Voltage (HV) 66kV-150kV (mainstream 66kV, 110kV, 132kV), Extra-Alto Voltage (EHV) 220kV-400kV+ (sicut 220kV, 330kV, 400kV), omnia secundum specificationes nominatae tensionis standardum IEC 60038 et ANSI C84.1.
  • Principia selectiva: Nucleus est "congruentia tensionis + adaptatio scenarii". ① Congruentia exacta tensionis: Tension nominata transformatoris terrae/grounding electi debet esse congrua cum tensione lineae systematis (exempli gratia, systema 110kV requirit gradum 110kV transformatoris terrae/grounding) ut evitetur fractura insulationis aut incompatibilitas parametrorum; ② Pro scenariis interno medio et basso voltage, preferendus est typus siccus (sicut insulatio resina cast pro areis chimicis 33kV), et pro scenariis externis alto voltage, preferendus est typus oleosus (sicut typus oleosus ONAF refrigertus pro substationibus externis 110kV); ③ Pro systematibus extra-alto voltage (220kV et supra), attendendum est ad parametrum impedentiae sequentiae zero ut assequatur coordinatio cum valore praestabilito protectionis relais.
Cognosce tui fornitori
Venditio Online
Ratio praestabilitae tradendae
Tempus responsionis
100.0%
≤4h
Brevis Descriptio Societatis
Locus Operis: 108000m²m² Numerus omnium laborantium: 700+ Summa Annua Exportatio (USD): 150000000
Locus Operis: 108000m²m²
Numerus omnium laborantium: 700+
Summa Annua Exportatio (USD): 150000000
Servitia
Genus Negotii: Design/Fabricatio/Venditio
Categorias Principales: apparatus electrum altum voltus/transformator
Gubernatio vitae
Servitia gestionis curae integralis pro quaestu, usu, conservatione et post-venditionem apparatus electricorum, securitatem operationis, continuationem imperii et usum electricitatis sine cura garantia.
Fornitori instrumentorum praeteritus est certificationem qualificationis platformae et iudicium technicum, ut ex fonte conformitas, professionalitas et fiducia servantur.

Producta Connexa

Cognitio Connexa

  • Transformatores Terrae Intelligentes pro Sustentatione Reticuli Insularis
    1. Fundamentum ProjectiProjecta photovoltaica (PV) distributa et systemata storage energiae celeriter progressuntur per totam Vietnamm et Asiam Southeast, tamen magnas difficultates obviant:1.1 Instabilitas Reticuli:Reticulum electricum Vietnam frequentes fluctuationes patitur (praecipue in zonis industrialibus septentrionalibus). In anno 2023, deficienciae carbonis electricitatis magnas obscuritates causaverunt, quae in perdita cotidiana plus quam USD 5 milliones resultabant. Systemata PV tradi
    12/18/2025
  • Functiones et Selectio Transformerum ad Terram in Stationibus Photovoltaicis
    1.Punctum Neutrale Constituendum et Stabilitas SystematisIn stationibus photovoltaicis, transformatores terrae efficaciter constituunt punctum neutrale systematis. Iuxta regulas pertinentes de potentia, hoc punctum neutrale certificat ut systema stabilitatem quandam conservet in casibus defectuum asymmetriorum, veluti "stabilizator" totius systematis potentiae.2.Capacitas Limitationis SupravoltarumIn stationibus photovoltaicis, transformatores terrae possunt efficaciter limitare supravoltus. Gen
    12/17/2025
  • Transformer Protection Settings: Zero-Sequence & Overvoltage Guide Instauratio Praeservationis Transformer: Guida ad Sequentiem Nullam & Excessum Tensionis
    1. Protectio per excessum currentis secundum sequentiam nullamCurrentus operativus pro protectio per excessum currentis secundum sequentiam nullam transformatorum de terra communiter determinatur ex currentu nominale transformatoris et maximo currentu secundum sequentiam nullam permisso durante defectibus in terra systematis. Communis ambitus praestabilitus est circa 0.1 ad 0.3 tempora currentus nominale, cum tempore operativo solito sit praestitutum inter 0.5 ad 1 secundum ut cito eliminari pos
    12/17/2025
  • Protectio Electrica: Transformatores Terrae et Impulsus Bus
    1. Systema Territorii Altae ResistentiaeTerritorium altae resistantiae potest limitare currentem defectus ad terram et moderate reducere supra-tensionem ad terram. Tamen non est necessarium coniungere directe inter punctum neutrum generatoris et terram resistorem magnae valentiae. Potius unus minor resistorem cum transformatore ad terram coniungi potest. Primaria spira transformatoris ad terram inter punctum neutrum et terram coniungitur, secundaria vero spira ad resistorem minorem coniungitur.
    12/17/2025
  • Methodi et Parametri Conductorum Transformatorum Terrae
    Configuraciones de Enrollado de Transformadores de Puesta a TierraLos transformadores de puesta a tierra se clasifican según la conexión del enrollado en dos tipos: ZNyn (zigzag) o YNd. Sus puntos neutrales pueden conectarse a un bobinado supresor de arco o a una resistencia de puesta a tierra. Actualmente, el transformador de puesta a tierra zigzag (tipo Z) conectado vía un bobinado supresor de arco o una resistencia de bajo valor es más comúnmente utilizado.1. Transformador de Puesta a Tierra
    12/05/2025
  • Cur Quo Usu Tenemur Ad Terram Transformatorem Et Ubi Is Usus Est
    Cur Quaerimus Transformatorium Terrae?Transformatorium terrae est unum ex maximis apparatibus in systematibus electricitatis, primum ad connectendum vel separandum punctum neutrum systematis ad terram, sic ut securitas et fides systematis electricitatis conservetur. Sub iacent rationes cur transformatoria terrae necessaria sunt: Ut Accidentia Electrica Praeveniantur:In operatione systematis electricitatis, propter diversas causas, contingere possunt conditiones anormales sicut effusio tensionis
    12/05/2025
Instrumenta Libera Cognata
Non invenisti adhuc opportunos fornitoris ut te inveniant Citationem Nunc Accipe
Non invenisti adhuc opportunos fornitoris ut te inveniant
Citationem Nunc Accipe
Inquiry
+86
Click to upload file
Descarica
Obtine Applicatio Commerciale IEE-Business
Utiliza app IEE-Business ad inveniendum apparatus obtinendumque solutiones coniungendum cum peritis et participandum in collaboratione industriale ubique et semper propter totam supportionem tuorum projectorum electricitatis et negotiorum