RHD-Tanquam mortuum SF6 Gas Circulator-Breaker

  • Customization 24 kV/25.8 kV/27 kV/145kV/138kV/230kV or Other Dead tank SF6 Gas Circuit-Breaker
  • Customization 24 kV/25.8 kV/27 kV/145kV/138kV/230kV or Other Dead tank SF6 Gas Circuit-Breaker
  • Customization 24 kV/25.8 kV/27 kV/145kV/138kV/230kV or Other Dead tank SF6 Gas Circuit-Breaker
  • Customization 24 kV/25.8 kV/27 kV/145kV/138kV/230kV or Other Dead tank SF6 Gas Circuit-Breaker

Attributa principalia

Marca ROCKWILL
Numerus Modeli RHD-Tanquam mortuum SF6 Gas Circulator-Breaker
Votum nominatum customization
currus electricus nominatus customization
Frequenta nominata 50/60Hz
Series RHD

Descriptiones productorum a fornitori

Descriptio

Descripio:

Omnes disiunctores circuituum sunt instructi mechanismis operativis puris ex virgulis, quod facit structuram simplicem et valde fidelem. Durabilitas mechanica mechanismi operativi est ultra 10000 vices, et est commodum ad manutenctionem et satisfacit requisitionibus mechanismi sine oleo et sine aere. Utitur principio arcus extinguendi ex proprio energio, et minuit potentiam operationis mechanismi et augit fiduciam operationis producti. Flanges adoptant designum structurae sigillorum duplicium, sigillum externum est aquae-proof et sigillum internum est aeris-proof. Itaque, potest multum minuere effluvium producti et facit productum magis aptum ad operationem exteram.

Introducio principalis functionis:

  • Alta interruptio currentis: Principium ex proprio energio

  • Bassa interruptio currentis: Principium puff type

  • Capacitas fundamentalis investigationis

Parametri technologici:

image.png

Structura dispositivi:

RHD-40.5

image.png

RHD-72.5

image.png

RHD-145

image.png

RHD-170

image.png

RHD-245

image.png

Q:Qualis est differentia inter vivarium SF6 et mortuarium?

A:In disiunctore circuituum vivario SF6, vas est in potentia lineae et energizatum durante operatione. Solent esse leviora et compactiora. In contrariis, vas disiunctoris circuituum mortuarii SF6 est terrae-conectatum, isolans partes altae-voltantis. Mortuariae species saepe habent melius insulamentum et sunt aptae ad altiores voltus, sed solent esse maiora et graviora.

Q:Quid est disiunctor circuituum mortuarius?

A:Disiunctor circuituum mortuarius est dispositivum electricum pro interruptendo currente in systematibus potentiae. Vas eius est terrae-conectatum, isolans ab partibus altae-voltantis. Repletum gas SF6 pro insulamento et extinguendo arcum, id aptum est ad applicationes altae-voltantis, offerens bonam performance electricam et securitatem.

Bibliotheca Documentorum Rerum
Restricted
RHD-Dead Tank SF6 Circuit Breaker Catalog
Catalogue
English
Consulting
Consulting
Restricted
138kV Station Switchgear Technical Specification with IEEE&ANSI
Technical Data Sheet
English
Consulting
Consulting
Restricted
138kV Station Switchgear Technical Specification with IEC
Technical Data Sheet
Chinese
Consulting
Consulting
FAQ
Q: Quae servitia customization non-standard voltage level pro hoc circuit breaker tank-type possunt praeberi
A:
Praebemus servitia consignata ad sequentes gradus tensionis, non limitata ad 11kV/12kV/13.8kV/15kV/22kV/33kV/44kV/60kV/63kV/66kV/69kV/88kV/
115kV/123kV/125kV/126kV/132kV/138kV/145kV/150kV/170kV/220kV/225kV/230kV/
245kV/275kV/330kV/345kV/400kV/756kV/800kV
 
 
 
Q: Quomodo iudicemus de tensione electra ad circuitum interrumpendi sulfuris hexafluoridi altiusculi?
A:

1.elige interruptorem ad nivellum tensionis coniunctum iuxta gradum rete electricitatis
Tensio standard (40.5/72.5/126/170/245/363/420/550/800/1100kV) concordat cum nominali tensio rete electricitatis. Exempli gratia, pro rete 35kV, eligitur interruptor 40.5kV. Iuxta normas sicut GB/T 1984/IEC 62271-100, tensio nominata est certa ≥ maxima tensio operativa rete electricitatis.
2.scenarii applicabiles ad tensionem non standard customizati
Tensio non standard customizata (52/123/230/240/300/320/360/380kV) utitur pro retibus electricitatis specialibus, sicut renovatio veterum retium et scenarii industriales specifici. Propter defectum tensionis standard aptae, fabricantes debent customizare secundum parametras rete, et post customizationem, insulatio et performantia arcus extinguendi debent verificari.
3.consequentes electionis nivelli tensionis errati
Eligendo nivellum tensionis inferius potest causare rupturam insulationis, ducens ad effluvium SF et damnum equipmenti; eligendo nivellum tensionis superius significanter crescit costos, crescit difficultates operationales, et potest etiam resultare in problematis mismatch performance.

Q: Quae sunt characteristicae structurales circuiti interruptoris in cisterna
A:

Structura Cisternae Integralis:

  • Structura Cisternae Integralis: Camera extinguentia arcum, medium insulans, et componentes coniuncti claudi sunt intra cisternam metallicam, quae plena est gas insulans (sicut sulfur hexafluoridum) vel oleum insulans. Hoc format spatium clausum et relativum independentem, quod efficaciter prohibet factores externos a componentibus internis affici. Haec constructio insulantiam et fiduciam apparati augeat, id aptum facit pro variis asperis ambientibus exteris.

Dispositio Cameræ Extinguendi Arcum:

  • Dispositio Cameræ Extinguendi Arcum: Camera extinguentia arcum saepe installatur intra cisternam. Eius structura designatur ut sit compacta, quae permittit efficientem extinctionem arcus in spatio limitato. Secundum diversos principia et technologias extinguentiae, specifica constructio camerae extinguentiae arcum variet, sed generaliter includit componentes claves sicut contactus, foramina, et materiae insulantes. Hi componentes cooperantur ad certificandum quod arcus cito et efficaciter extinguitur quando interruptor currentem interrumpit.

Mechanisma Operativus:

  • Mechanisma Operativus: Mechanismi operativi communes includunt mechanismos operatos per vim elasticam et mechanismos operatos per vim hydraulicam.

  • Mechanismus Operatus per Vim Elastica: Huiusmodi mechanisma simplici structura, alta fide, et facile conservanda est. Is movet operationes aperiendi et claudi interruptoris per conseruationem et emittentiam virem elasticarum.

  • Mechanismus Operatus per Vim Hydraulicam: Hic mechanisma praebet praestantias sicut altam potentiam emissam et motum suavem, id aptum faciens pro interruptoribus magni tensio et magni currentis.

Cognosce tui fornitori
Venditio Online
Ratio praestabilitae tradendae
Tempus responsionis
100.0%
≤4h
Brevis Descriptio Societatis
Locus Operis: 108000m²m² Numerus omnium laborantium: 700+ Summa Annua Exportatio (USD): 150000000
Locus Operis: 108000m²m²
Numerus omnium laborantium: 700+
Summa Annua Exportatio (USD): 150000000
Servitia
Genus Negotii: Design/Fabricatio/Venditio
Categorias Principales: apparatus electrum altum voltus/transformator
Gubernatio vitae
Servitia gestionis curae integralis pro quaestu, usu, conservatione et post-venditionem apparatus electricorum, securitatem operationis, continuationem imperii et usum electricitatis sine cura garantia.
Fornitori instrumentorum praeteritus est certificationem qualificationis platformae et iudicium technicum, ut ex fonte conformitas, professionalitas et fiducia servantur.

Producta Connexa

Cognitio Connexa

  • Culpae et Tractatio Terrae Unipolaris in Lineis Distributionis 10kV
    Characteristica et Instrumenta Detegendi Defectus Terrae Monofasiales1. Characteristica Defectuum Terrae MonofasialiumSigna Centralia Admonitionis:Campanula admonitionis sonat, et lucerna indicativa inscripta „Defectus Terrae in Sectione Omnibus [X] kV [Y]“ accenditur. In systematibus ubi punctum neutrum per bobinam Petersen (bobinam suppressionis arcus) ad terram connectitur, lucerna indicativa „Bobina Petersen Operatur“ etiam accenditur.Indicationes Voltmetri Monitoris Isolationis:Tensio phase
    01/30/2026
  • Modus operationis terre iunctae puncti neutralis pro transformatoribus retis electricitatis 110kV~220kV
    Dispositio modi operis terrae puncti neutralis pro transformatoribus rete electricitatis 110kV~220kV debet exigentias tolerationis insulationis puncti neutralis transformatorum complere, et simul conari ut impedimentum sequentiae nullae stationum transformationis fere immutatum maneat, dum certatur ne impedimentum sequentiae nullae compositum in quocumque puncto raptus circuiti systematis ultra ter impedimentum sequentiae positivae compositum excedat.Pro transformatoribus 220kV et 110kV in novis
    01/29/2026
  • Cur Quare Substationes Lapidem Gravem Calculos et Rupem Fractam Utuntur
    Cur Quare Substationes Utuntur Lapidibus, Gravibus, Piscinis et Saxis Tritis?In stationibus transformationis, instrumenta ut transformatores electricitatis et distributionis, lineae transmissionis, transformatores tensionis, transformatores currentis et commutatores disiunctionis omnia terram exigunt. Praeter terram, nunc profundius explorabimus cur gravia et saxa trita in stationibus transformationis saepe utuntur. Quamquam videantur ordinaria, isti lapides partem criticam iuxtaque functionalem
    01/29/2026
  • Cur autem nucleus transformatoris tantum in uno puncto terram tangere debet Nonne terra multipuncta fidelius est
    Cur ergo nucleus transformatoris terram tangere debet?In operatione, nucleus transformatoris, simul cum structuris, partibus et componentibus metallicis quae fixant nucleum et spiras, in forti campo electrico situs est. Sub influentia huius campi electrici, potentialem relativum altum ad terram comparatum acquirunt. Si nucleus non terra tangitur, differentia potentialis inter nucleum et structuras claudicantes et vas terratum existet, quae possit ad intermitterentiam dismissionem ducere.Praetere
    01/29/2026
  • Intellegere Terram Neutralis Transformatoris
    I. Quid est Punctum Neutrum?In transformatoribus et generatoribus, punctum neutrum est locus specificus in spira ubi absoluta tensio inter hunc locum et singula terminalia externa aequalis est. In diagrammate infra, punctumOrepraesentat punctum neutrum.II. Cur Punctum Neutrum Terrendum Est?Modus connexionis electricae inter punctum neutrum et terram in systemate AC triphasico diciturmodus terrendi puncti neutri. Hic modus directe afficit:Securitatem, fidem et oeconomiciam retelectrici;Selectione
    01/29/2026
  • Quid est Differentia Inter Transformatores Rectificatores et Transformatores Potentiae?
    Quid est transformator rectificans?"Conversio potentiae" est terminus generalis qui conversionem, inversionem et conversionem frequentiae comprehendit, inter quas conversio praecipue usitatissima est. Apparatus rectificans convertit potentiam AC input in DC output per rectificationem et filtrationem. Transformator rectificans servit ut transformator alimentationis pro talibus apparatibus rectificantibus. In applicationibus industrialibus, plerumque alimenta DC obtinentur per combinandum transfor
    01/29/2026

Solutiones Relatae

  • Design Solution of 24kV Siccum Aera Insulatum Ring Main Unit
    Combinatio Solidi Insulationis Adiuvantis + Insulationis Aereae Siccae repraesentat directionem pro RMU 24kV. Per requirementa insulationis cum compactitate equilibrata et adiuvante solidum insulationis, testes insulationis sine magnificatione significativa dimensionum inter phasos et inter phasos et terram transigi possunt. Inclusio columnae pole solidificat insulationem pro interruptore vacuo et conductoribus eius coniunctis.Maintinendo spatium phasorum exiens 24kV ad 110mm, intensitas electri
    08/16/2025
  • Optimizatio Design Schematum pro Unitate Circulorum Principalium Aere Insulata 12kV ad Minuendam Probabilitatem Disruptionis Emissionis
    Cum celeri progressus industriae electricitatis, conceptus ecologicus de carbonis minore, energiae servanda, et conservatione ambientis profundissime integratus est in designum et fabricam productorum electricorum pro distributione et generatione electricitatis. Unitas Distributiva Circuli (RMU) est dispositivum electricum clavem in retibus distributionis. Securitas, conservatio ambientis, fides operativa, efficacia energetica, et oeconomia sunt tendentiae inevitabiles in eius progressu. RMUs tr
    08/16/2025
  • Analyse communium problematum in unitatibus principali circuitu isolatis gas 10kV (RMUs)
    Introductio:​​RMUs insulati gaseis 10kV sunt amplissime usitati propter multas suas utilitates, sicut quod sint perfecte clausi, habeant excellentem insulativam qualitatem, non requirant maintenance, sint compacti, et praebent installationem flexibilem et commodam. In hoc stadio, paulatim facti sunt nodus criticus in rete distributionis urbano anulari et iocabuntur partem significativam in systemate distributionis electricitatis. Difficultates in RMUs insulatis gaseis possunt graviter impingere
    08/16/2025
Non invenisti adhuc opportunos fornitoris ut te inveniant Citationem Nunc Accipe
Non invenisti adhuc opportunos fornitoris ut te inveniant
Citationem Nunc Accipe
Inquiry
+86
Click to upload file
Descarica
Obtine Applicatio Commerciale IEE-Business
Utiliza app IEE-Business ad inveniendum apparatus obtinendumque solutiones coniungendum cum peritis et participandum in collaboratione industriale ubique et semper propter totam supportionem tuorum projectorum electricitatis et negotiorum