• HVR-63 Series Generator circuit-breakers
HVR-63 Series Generator circuit-breakers
discuss personally
Model
HVR-63S
HVR-63XS
Basic info
Brand ROCKWILL
Model NO. HVR-63 Series Generator circuit-breakers
Rated voltage 24kV
Rated normal current 8000A
Rated frequency 50/60Hz
Rated short circuit breaking current 63kA
Series HVR-63 Series
Product Detail

Overview 

The HVR-63 generator circuit-breaker (GCB) is the latest generation of well-proven HGI generator circuit-breaker series and it is best suited for retrofit in power plants with a unit power of up to 180 MW. The open design and small footprint make it perfect for systems with open busbar and short-circuit ratings up to 63 kA. Our innovative built-in direct contact ablation display offers the highest degree of safety and reliability for power plants with frequent switching operations such as pumped storage power plants. The HVR generator circuitbreaker is available as HVR-63XS with rated continuous currents up to 6300 A or as HVR-63S with rated continuous currents up to 8000 A. Both variants offer flexible busbar connection. With this new HVR-63 GCB, continues to lead the way in designing the most advanced GCBs.

Hydraulic spring operating mechanism

Advanced operating system delivers stability and dependability The hydraulic spring operating mechanism combines the advantages of a hydraulic operating mechanism with those of spring energy storage system. Energy storage is accomplished with the aid of a disk spring assembly, with the advantages of stability, reliability and resistance to temperature variability. Tripping of the operating mechanism and energy output arebased on proven design elements of the hydraulic operating technique, such as control valves and hydraulic cylinders. The operating mechanism is based on the differential piston principle. For the closing operation the piston head side is isolated from the low pressure and simultaneously connected to the high pressure oil volume. As long as the pressure is maintained, the piston remains in the “closed” position. A pressure controlled mechanical interlock prevents movement of the piston to the “open” position in case of a pressure drop. For the opening operation, the piston head side is isolated from the high pressure and simultaneously connected to the low pressure oil volume. The charging state of the spring disk assembly is controlled by switching elements, actuating the pump motor to immediately maintain the oil pressure. A non-return valve between pump and high-pressure oil volume prevents pressure loss in the event of a pump outage. The hydraulic system is hermetically sealed against atmosphere. The mechanically operated position indicator provides reliable indication of the circuit-breaker position. The drive operates all three circuit-breaker poles simultaneously by mechanical linkages, thus keeping the switching time difference between the poles to a minimum.

Technology parameters

 

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Research and Application of Communication Security Strategies for Smart Meters
Research and Application of Communication Security Strategies for Smart Meters
1. Security Threats Facing Smart Meter Communications1.1 Physical Layer Security ThreatsPhysical layer security threats refer to factors that damage or interfere with the hardware devices and physical connections of smart meters, directly affecting their normal operation and data transmission. From the perspective of equipment damage, harsh natural environments such as lightning strikes, floods, and earthquakes can directly destroy the hardware circuits and structures of smart meters, rendering
Echo
09/01/2025
Analysis of Issues and Causes in Smart Meter Testing
Analysis of Issues and Causes in Smart Meter Testing
1. Issues and Cause Analysis in Smart Electricity Meter TestingDuring the verification of smart electricity meters, inspections must be conducted on the meter’s appearance, as well as the clarity and integrity of nameplate markings. Additionally, careful checks are required for physical damage and whether the display can show digits completely. A power-on inspection is also necessary. If error codes appear on the display after power-up, faults should be identified and addressed according to the
Oliver Watts
09/01/2025
Analysis of Common Operational Fault Causes in Smart Electricity Meters
Analysis of Common Operational Fault Causes in Smart Electricity Meters
With the continuous development of smart grids, smart electricity meters are being increasingly widely applied, and various types of operational faults in smart meters are frequently encountered in energy measurement work. This paper analyzes the causes of smart meter failures and proposes corresponding solutions, using several actual operational fault cases as examples.1. Black ScreenA black screen refers to a powered meter with no display, which is the most commonly occurring fault in field-op
Felix Spark
09/01/2025
What tests are required for a qualified smart electricity meter?
What tests are required for a qualified smart electricity meter?
In today's world, not wearing a watch is no longer unusual, but not having an electricity meter is a serious issue. As a measuring instrument vital to people's daily lives, the electricity meter is an essential tool for power consumption measurement and billing in every household. According to current national strategic requirements for smart grid development, smart electricity meters have been widely applied and promoted, bringing entirely new and extensive market opportunities to the metering
Oliver Watts
09/01/2025
Discussion on Fault Diagnosis and Handling Technologies for Smart Meters in Electricity Inspections
Discussion on Fault Diagnosis and Handling Technologies for Smart Meters in Electricity Inspections
1 Analysis of Smart Meter Faults and Their Impact on the Power Grid1.1 Introduction to Smart Meter Functions and Their Critical Role in Modern Power GridsSmart meters exchange data in real time with power companies through two-way communication, enabling functions such as remote meter reading and dynamic tariff adjustment. This capability allows users to adjust their consumption based on real-time pricing, achieving energy savings and cost reduction. Meanwhile, smart meters support grid automati
Felix Spark
09/01/2025
Analysis of the Integrated Application of Smart Meters and Meter Reading, Verification, and Billing Information Systems
Analysis of the Integrated Application of Smart Meters and Meter Reading, Verification, and Billing Information Systems
Meter reading, verification, and billing are critical operations for power companies, and their efficiency directly impacts the company's sustainable development. In recent years, with the widespread adoption of intelligent technologies, smart meters have been promoted and applied in power companies, driving transformation in meter reading and billing operations. The integrated application of smart meters and meter reading, verification, and billing information systems has become a key developme
Echo
09/01/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!