Fusibles AR DNT-O1J Series Semiconductores Equipos de Protección Fusibles

  • AR Fuses DNT-O1J Series Semiconductors Equipment Protection Fuses
  • AR Fuses DNT-O1J Series Semiconductors Equipment Protection Fuses
  • AR Fuses DNT-O1J Series Semiconductors Equipment Protection Fuses

Attributa principalia

Marca Switchgear parts
Numerus Modeli Fusibles AR DNT-O1J Series Semiconductores Equipos de Protección Fusibles
Votum nominatum AC 1000V
currus electricus nominatus 630-1500A
Capacitas disiuncionis 100kA
Series DNT-O1J

Descriptiones productorum a fornitori

Descriptio

Quae sunt communes modi casus pro fusibus semiconductivis, et quomodo possunt praeveniri?

Fusus semiconductivi designantur ut protegant componentes electronicos ab excessu currentis qui possit damnum facere aut periculum creare. Hi sunt elementum criticum in administratione potestatis et protectione circuituum. Tamen, sicut omnes componentes, hi possum fallere, et eorum modi casus possunt latissime categorizari ut sequitur:

1.Casu Overload: Communis modus casus pro fuso est conditio overload ubi currentis excedit capacitas fusi nominata. Hoc est operatio intenta—fusum debet “blow” vel circuitum aperire sub conditionibus overload ad praeventionem damni ad componentes circuituum.

2.Casu Fatigue: Per tempus, elementum fusi degradari potest propter thermicam cyclationem vel stress repetitus a currentibus surgo quae non attingunt nivellum necessarium ad fusum blow. Hoc potest eventualiter ducere ad casum fatigue ubi fusus blow ad currentem minus quam nominatum.

3.Casu Environmental: Expositio ad altas temperaturas, umiditatem, vel ambientes corrosivos degradari possunt materiales fusi, ducendo ad praeceps casus.

4.Defectus Fabricationis: Defectus sicut impuritates in elementum fusi, impropria adiectio capitis extremi, vel incorrecta magnitudo facere possunt ut fusus casu praeceps vel non operetur ut intentum.

5.Improprium Selectio vel Installatio: Si fusus non proprie selectus est pro sua applicatione, is posse non recte operari. Exempli gratia, usus fusi cum rating nimis proximus ad normalis currentem operativum potest ducere ad tripping molestiae, dum fusus cum rating nimis altus non adeo protecturus sit circuitum.

6.Transientia Voltage: Spikes vel surges in voltage possunt causare incrementum currentis qui potest fusum blow, etiam si surge brevis est.

Ad praeventionem horum modorum casus, sequentes mensurae capi possunt:

Proprium Sizing: Certificare ut fusi recte sint magnitudine ad circuitum quem protegunt. Fusus debet habere rating currentis super normalem currentem operativum sed inferius currentem qui possit damnum facere ad componentes circuituum.

Protectio Environmental: Uti fusi cum approprio rating environmental pro applicatione, et, si necessario, addere protectionem additionalem contra umiditatem, extrema temperaturarum, vel substantias corrosivas.

Control Qualitatis: Procurare fusi ab fabricatoribus reputatis qui adstrictas standards controlis qualitatis adhaerent ad minimizationem risqui defectus fabricationis.

Recta Installatio: Sequere guidelines fabricatoris pro installatione fusi, includens rectam montationem et contactum cum holder fusi, ad vitandum problemata relativa ad conexiones laxes vel improprium pressionem contactus.

Cycling Durabilitas: Pro applicationibus cum frequentibus surgis currentis, select fusi designatos ut sustineant maiorem numerum cycles.

Protectio Surge: Ut devices protectionis surge additionales in conjunctione cum fuis uti ad gestendum transientia voltage et spikes, sicut varistores oxidis metallici (MOVs), diodes suppressionis transientis voltage (TVS), vel arresters surge.

Routine Inspection: Implementare programam inspectionis et maintenance routine ad examinandum signa degradationis fusi vel damage environmental.

Per intellegentiam communium modorum casus fusi semiconductivi et agendi ad praeventionem earum, fidelitas systematum electronicorum significanter meliorari potest, reducendo downtime et costus maintenance.

Parametri basici fusorum

Model producti Magnitudo Voltage nominatum          V Currents nominatus      A Capacitas breaking nominata      kA
DNT1-01J-160 1 AC 1000 160 100
DNT1-01J-200 200
DNT1-01J-250 250
DNT1-01J-315 315
DNT1-01J-350 350
DNT1-01J-400 400
DNT1-01J-450 450
DNT1-01J-500 500
DNT1-01J-550 550
DNT1-01J-630 630
DNT2-01J-350 2 350
DNT2-01J-400 400
DNT2-01J-450 450
DNT2-01J-500 500
DNT2-01J-550 550
DNT2-01J-630 630
DNT2-01J-710 710
DNT2-01J-800 800
DNT3-01J-630 3 630
DNT3-01J-710 710
DNT3-01J-800 800
DNT3-01J-900 900
DNT3-01J-1000 1000
DNT3-01J-1100 1100
DNT3-01J-1250 1250
DNT3-01J-1400 1400
DNT3-01J-1500 1500
Cognosce tui fornitori
Venditio Online
Ratio praestabilitae tradendae
Tempus responsionis
100.0%
≤4h
Brevis Descriptio Societatis
Locus Operis: 1000m² Numerus omnium laborantium: Summa Annua Exportatio (USD): 300000000
Locus Operis: 1000m²
Numerus omnium laborantium:
Summa Annua Exportatio (USD): 300000000
Servitia
Genus Negotii: Venditio
Categorias Principales: pars componentium/Instrumenta inspectionis/apparatus electrum altum voltus/Apparatus electri bassa tensione/Instrumenta et mensurae/Instrumenta productiva/Ferramentae electricitatis
Gubernatio vitae
Servitia gestionis curae integralis pro quaestu, usu, conservatione et post-venditionem apparatus electricorum, securitatem operationis, continuationem imperii et usum electricitatis sine cura garantia.
Fornitori instrumentorum praeteritus est certificationem qualificationis platformae et iudicium technicum, ut ex fonte conformitas, professionalitas et fiducia servantur.

Producta Connexa

Cognitio Connexa

  • Culpae et Tractatio Terrae Unipolaris in Lineis Distributionis 10kV
    Characteristica et Instrumenta Detegendi Defectus Terrae Monofasiales1. Characteristica Defectuum Terrae MonofasialiumSigna Centralia Admonitionis:Campanula admonitionis sonat, et lucerna indicativa inscripta „Defectus Terrae in Sectione Omnibus [X] kV [Y]“ accenditur. In systematibus ubi punctum neutrum per bobinam Petersen (bobinam suppressionis arcus) ad terram connectitur, lucerna indicativa „Bobina Petersen Operatur“ etiam accenditur.Indicationes Voltmetri Monitoris Isolationis:Tensio phase
    01/30/2026
  • Modus operationis terre iunctae puncti neutralis pro transformatoribus retis electricitatis 110kV~220kV
    Dispositio modi operis terrae puncti neutralis pro transformatoribus rete electricitatis 110kV~220kV debet exigentias tolerationis insulationis puncti neutralis transformatorum complere, et simul conari ut impedimentum sequentiae nullae stationum transformationis fere immutatum maneat, dum certatur ne impedimentum sequentiae nullae compositum in quocumque puncto raptus circuiti systematis ultra ter impedimentum sequentiae positivae compositum excedat.Pro transformatoribus 220kV et 110kV in novis
    01/29/2026
  • Cur Quare Substationes Lapidem Gravem Calculos et Rupem Fractam Utuntur
    Cur Quare Substationes Utuntur Lapidibus, Gravibus, Piscinis et Saxis Tritis?In stationibus transformationis, instrumenta ut transformatores electricitatis et distributionis, lineae transmissionis, transformatores tensionis, transformatores currentis et commutatores disiunctionis omnia terram exigunt. Praeter terram, nunc profundius explorabimus cur gravia et saxa trita in stationibus transformationis saepe utuntur. Quamquam videantur ordinaria, isti lapides partem criticam iuxtaque functionalem
    01/29/2026
  • Cur autem nucleus transformatoris tantum in uno puncto terram tangere debet Nonne terra multipuncta fidelius est
    Cur ergo nucleus transformatoris terram tangere debet?In operatione, nucleus transformatoris, simul cum structuris, partibus et componentibus metallicis quae fixant nucleum et spiras, in forti campo electrico situs est. Sub influentia huius campi electrici, potentialem relativum altum ad terram comparatum acquirunt. Si nucleus non terra tangitur, differentia potentialis inter nucleum et structuras claudicantes et vas terratum existet, quae possit ad intermitterentiam dismissionem ducere.Praetere
    01/29/2026
  • Intellegere Terram Neutralis Transformatoris
    I. Quid est Punctum Neutrum?In transformatoribus et generatoribus, punctum neutrum est locus specificus in spira ubi absoluta tensio inter hunc locum et singula terminalia externa aequalis est. In diagrammate infra, punctumOrepraesentat punctum neutrum.II. Cur Punctum Neutrum Terrendum Est?Modus connexionis electricae inter punctum neutrum et terram in systemate AC triphasico diciturmodus terrendi puncti neutri. Hic modus directe afficit:Securitatem, fidem et oeconomiciam retelectrici;Selectione
    01/29/2026
  • Quid est Differentia Inter Transformatores Rectificatores et Transformatores Potentiae?
    Quid est transformator rectificans?"Conversio potentiae" est terminus generalis qui conversionem, inversionem et conversionem frequentiae comprehendit, inter quas conversio praecipue usitatissima est. Apparatus rectificans convertit potentiam AC input in DC output per rectificationem et filtrationem. Transformator rectificans servit ut transformator alimentationis pro talibus apparatibus rectificantibus. In applicationibus industrialibus, plerumque alimenta DC obtinentur per combinandum transfor
    01/29/2026
Non invenisti adhuc opportunos fornitoris ut te inveniant Citationem Nunc Accipe
Non invenisti adhuc opportunos fornitoris ut te inveniant
Citationem Nunc Accipe
Inquiry
+86
Click to upload file
Descarica
Obtine Applicatio Commerciale IEE-Business
Utiliza app IEE-Business ad inveniendum apparatus obtinendumque solutiones coniungendum cum peritis et participandum in collaboratione industriale ubique et semper propter totam supportionem tuorum projectorum electricitatis et negotiorum