75 kVA ~ 2500 kVA UL-Listatus Explosio-Proof Standard Pad-Mounted Transformer

  • 75 kVA ~ 2500 kVA UL-Listed Explosion-Proof Standard Pad-Mounted Transformer

Attributa principalia

Marca Vziman
Numerus Modeli 75 kVA ~ 2500 kVA UL-Listatus Explosio-Proof Standard Pad-Mounted Transformer
Frequenta nominata 50/60Hz
Capacitas nominata 2500kVA
Tensio primum 33kV
voltus secundarius 0.4kV
Series ZGS

Descriptiones productorum a fornitori

Descriptio

Descriptio:

Transformator Pad-Mounted Explosion-Proof Standard UL-Listatus est transformator oleo-immersus pad-mounted certificatus a Underwriters Laboratories (UL), specialiter designatus pro ambientes periculosos. Suas certificationes et standardes core sunt:

  • Certificatio UL: Compatit cum UL 506 (Standard Transformatoris) et UL 1203 (Standard Equipmenti Explosion-Proof), assecurans operationem tuto in ambientes periculosos.
  • Rating Explosion-Proof: Usualiter notatus ut Class I, Division 1 (pro ambientes flammabilis gas) vel Class II, Division 1 (pro ambientes pulvis combustibilis), adhærens ad National Electrical Code (NEC 500/505).
  • Standardes Structural: Basati super IEEE C57.12.20 (American Pad-Mounted Transformer Standard) et NEMA 3R/4X (Enclosure Rating Standards).

Core Design Features:

  • Enclosure Explosion-Proof: Constructum ex aluminio fundito vel aço inox, superficies iuncturales et hiatus strictim compatunt cum UL 1203 (e.g., hiatus ≤0.15mm) ad prohibendum propagationem flammae durante arcing internum.
  • Systema Relief Pressure: Equipatum cum valvulis dualibus redundantibus relief pressure (pressura operativa 55±5kPa) et spark arrestors ad prohibendum rupturn vasorum et explosiones secundarias.
  • Insulation Oleo-Immersus: Utilizat oleum insulationis alti flash-point (e.g., oleum silicium cum flash point >300°C) vel β-fluid (compatens cum UL 3406) ad reducendum pericula incendii.
  • Rating Sealing: Habet constructionem full-welded cum vasculis corrugatis, transiens tests explosionis UL 50E (test explosionis mixture metano-aer) ad prohibendum ingressum substantiarum combustibilium.
  • Connectiones Electricales: Equipatum cum glandis cable explosion-proof (certificata UL 1203) et juncturas Ex d-type flameproof ad assecurandum quod scintillæ ad terminales non ignitent gases ambientales.

Functions et Core Applications:

  • Supply Power Tuta: Facit conversionem energiæ electricæ in ambientes flammabilis dum prohibet scintillas vel altas temperaturas ab triggerando explosions.
  • Isolation Fault: Continet faultus internos (e.g., arcing, decompositio olei) intra enclosure per design explosion-proof.
  • Adaptation Environmental: Cum rating protectionis IP66, resistit ingressu gas corrosivorum et pulveris.

Parameter:

Cognosce tui fornitori
Venditio Online
Ratio praestabilitae tradendae
Tempus responsionis
100.0%
≤4h
Brevis Descriptio Societatis
Locus Operis: 10000m² Numerus omnium laborantium: 300 Summa Annua Exportatio (USD): 150000000
Locus Operis: 10000m²
Numerus omnium laborantium: 300
Summa Annua Exportatio (USD): 150000000
Servitia
Genus Negotii: Design/Fabricatio/Venditio
Categorias Principales: apparatus electrum altum voltus/transformator
Gubernatio vitae
Servitia gestionis curae integralis pro quaestu, usu, conservatione et post-venditionem apparatus electricorum, securitatem operationis, continuationem imperii et usum electricitatis sine cura garantia.
Fornitori instrumentorum praeteritus est certificationem qualificationis platformae et iudicium technicum, ut ex fonte conformitas, professionalitas et fiducia servantur.

Producta Connexa

Cognitio Connexa

  • Culpae et Tractatio Terrae Unipolaris in Lineis Distributionis 10kV
    Characteristica et Instrumenta Detegendi Defectus Terrae Monofasiales1. Characteristica Defectuum Terrae MonofasialiumSigna Centralia Admonitionis:Campanula admonitionis sonat, et lucerna indicativa inscripta „Defectus Terrae in Sectione Omnibus [X] kV [Y]“ accenditur. In systematibus ubi punctum neutrum per bobinam Petersen (bobinam suppressionis arcus) ad terram connectitur, lucerna indicativa „Bobina Petersen Operatur“ etiam accenditur.Indicationes Voltmetri Monitoris Isolationis:Tensio phase
    01/30/2026
  • Modus operationis terre iunctae puncti neutralis pro transformatoribus retis electricitatis 110kV~220kV
    Dispositio modi operis terrae puncti neutralis pro transformatoribus rete electricitatis 110kV~220kV debet exigentias tolerationis insulationis puncti neutralis transformatorum complere, et simul conari ut impedimentum sequentiae nullae stationum transformationis fere immutatum maneat, dum certatur ne impedimentum sequentiae nullae compositum in quocumque puncto raptus circuiti systematis ultra ter impedimentum sequentiae positivae compositum excedat.Pro transformatoribus 220kV et 110kV in novis
    01/29/2026
  • Cur Quare Substationes Lapidem Gravem Calculos et Rupem Fractam Utuntur
    Cur Quare Substationes Utuntur Lapidibus, Gravibus, Piscinis et Saxis Tritis?In stationibus transformationis, instrumenta ut transformatores electricitatis et distributionis, lineae transmissionis, transformatores tensionis, transformatores currentis et commutatores disiunctionis omnia terram exigunt. Praeter terram, nunc profundius explorabimus cur gravia et saxa trita in stationibus transformationis saepe utuntur. Quamquam videantur ordinaria, isti lapides partem criticam iuxtaque functionalem
    01/29/2026
  • Cur autem nucleus transformatoris tantum in uno puncto terram tangere debet Nonne terra multipuncta fidelius est
    Cur ergo nucleus transformatoris terram tangere debet?In operatione, nucleus transformatoris, simul cum structuris, partibus et componentibus metallicis quae fixant nucleum et spiras, in forti campo electrico situs est. Sub influentia huius campi electrici, potentialem relativum altum ad terram comparatum acquirunt. Si nucleus non terra tangitur, differentia potentialis inter nucleum et structuras claudicantes et vas terratum existet, quae possit ad intermitterentiam dismissionem ducere.Praetere
    01/29/2026
  • Intellegere Terram Neutralis Transformatoris
    I. Quid est Punctum Neutrum?In transformatoribus et generatoribus, punctum neutrum est locus specificus in spira ubi absoluta tensio inter hunc locum et singula terminalia externa aequalis est. In diagrammate infra, punctumOrepraesentat punctum neutrum.II. Cur Punctum Neutrum Terrendum Est?Modus connexionis electricae inter punctum neutrum et terram in systemate AC triphasico diciturmodus terrendi puncti neutri. Hic modus directe afficit:Securitatem, fidem et oeconomiciam retelectrici;Selectione
    01/29/2026
  • Quid est Differentia Inter Transformatores Rectificatores et Transformatores Potentiae?
    Quid est transformator rectificans?"Conversio potentiae" est terminus generalis qui conversionem, inversionem et conversionem frequentiae comprehendit, inter quas conversio praecipue usitatissima est. Apparatus rectificans convertit potentiam AC input in DC output per rectificationem et filtrationem. Transformator rectificans servit ut transformator alimentationis pro talibus apparatibus rectificantibus. In applicationibus industrialibus, plerumque alimenta DC obtinentur per combinandum transfor
    01/29/2026

Solutiones Relatae

Non invenisti adhuc opportunos fornitoris ut te inveniant Citationem Nunc Accipe
Non invenisti adhuc opportunos fornitoris ut te inveniant
Citationem Nunc Accipe
Inquiry
+86
Click to upload file
Descarica
Obtine Applicatio Commerciale IEE-Business
Utiliza app IEE-Business ad inveniendum apparatus obtinendumque solutiones coniungendum cum peritis et participandum in collaboratione industriale ubique et semper propter totam supportionem tuorum projectorum electricitatis et negotiorum