Insulator scyphus unipolaris 550kV

  • 550kV single-phase bowl insulator

Attributa principalia

Marca Switchgear parts
Numerus Modeli Insulator scyphus unipolaris 550kV
Votum nominatum 550kV
Series RN

Descriptiones productorum a fornitori

Descriptio

Insulator monophasicus vitreus de 550kV est componentis insulantis principale in apparatu commutatorio metallico clauso gas insulato (GIS), et designatio eius debet exigentias uniformitatis campi electrici, fortitudinis mechanicae, et protectionis ambientalis sub altis tensionibus implere. Sequitur analysin technicam comprehensivam basatam super recentissimis studiis:
1、 Optimizatio designati et melioramentum praestantiae
Optimizatio geometrica
Adoptans designatum "crassum ad utraque latera et tenuem in medio", maxima intensitas campi electrici secundum superficiem concavam diminuitur per 25.4%, et deformatio diminuitur per 29.9%
Variabiles crassitudinis (H ₁, H ₂, etc.) et variabiles contouris (C ₁ ₂, C ₁ ∝, etc.) per algorithmon geneticum optimizantur ad praestantiam electricam et mechanicam aequilibrare
Applicatio materialium gradientium dielectricorum
Introducendo regionem dielectricam constantem altam iuxta flangiam terrae (sicut resina epoxyda repleta dioxydo titanii) significanter melioratur distortio campi electrici et usus gas SF6 diminuitur per 15%
Impressio tridimensio cum technologia fundendi efficit structuram dielectricam non uniformem, augmentans tensionem fulgurationis per 13.8%
2、 Parametri key et verificatio experimentalis
Praestantia electrica
Tensio ferenda frequentialis 230kV, tensio ferenda impulsus fulminis 550kV, capacitas dispergendi localiter ≤ 5pC
Post optimizandum, tensio fulgurationis insulatoris comparata cum structura consueta augmentatur per 13.6%, et adhuc potest augmentari per 6.7% in praesentia corporum metallicorum extraneorum
Praestantia mechanica
Maxima deformatio diminuitur ad 0.45mm, et stressus interfacialis minor est quam limitis materialis (70MPa)
Firmitas structurae verificatur per experimentum fracturae pressionis aquae (1.5 vice pressione nominata)
3、 Processus fabricandi et amicitia ambientalis
Technologia progressiva
Usus aluminae/resinae photosensibilis impressio tridimensio corpus dielectricum constantem parvam (ε=3.98-4.20), area dielectrica constantem magnam (ε=11.32-14.58) funditur in vacuo, sine designamento anuli aluminii simplificatur structura, minuens periculum effluvii gas SF6
Beneficia ambientalia
Usus materialium compositarum epoxydinarum diminuitur per 6.1%, et usus gas SF6 diminuitur per 15%
4、 Scenarii applicationis typici
Transmissio ultra alta tensio: sicut apparatus GIS de 550kV, aptus pro substationibus compactis vel in ambientibus altitudinis elevatae
Systema GIL: Insulatoribus peltatis optimatis potest maxima intensitas campi electrici in regionibus gaseis diminui per 13.6%, meliorans fidem operationis GIL

Nota: Customizatio cum diagrammatibus est disponibilis

Cognosce tui fornitori
Venditio Online
Ratio praestabilitae tradendae
Tempus responsionis
100.0%
≤4h
Brevis Descriptio Societatis
Locus Operis: 1000m² Numerus omnium laborantium: Summa Annua Exportatio (USD): 300000000
Locus Operis: 1000m²
Numerus omnium laborantium:
Summa Annua Exportatio (USD): 300000000
Servitia
Genus Negotii: Venditio
Categorias Principales: pars componentium/Instrumenta inspectionis/apparatus electrum altum voltus/Apparatus electri bassa tensione/Instrumenta et mensurae/Instrumenta productiva/Ferramentae electricitatis
Gubernatio vitae
Servitia gestionis curae integralis pro quaestu, usu, conservatione et post-venditionem apparatus electricorum, securitatem operationis, continuationem imperii et usum electricitatis sine cura garantia.
Fornitori instrumentorum praeteritus est certificationem qualificationis platformae et iudicium technicum, ut ex fonte conformitas, professionalitas et fiducia servantur.

Producta Connexa

Cognitio Connexa

  • Accidentia Transformatoris Principalis et Questiones Operationis Gas Luminis
    1. Registri accidentis (XIX Martii, MMXIX)Hora XVI:XIIX die XIX Martii, MMXIX, monitorium background reportavit actionem gas levis transformatoris principis numeri III. Conformiter Codex Operationis Transformatorum Electricitatis (DL/T572-2010), personale operationis et maintenance (O&M) inspectavit statum in situ transformatoris principis numeri III.Confirmatio in situ: Panel non-electricus protectionis WBH transformatoris principis numeri III reportavit actionem gas levis phase B corpus tr
    02/05/2026
  • Culpae et Tractatio Terrae Unipolaris in Lineis Distributionis 10kV
    Characteristica et Instrumenta Detegendi Defectus Terrae Monofasiales1. Characteristica Defectuum Terrae MonofasialiumSigna Centralia Admonitionis:Campanula admonitionis sonat, et lucerna indicativa inscripta „Defectus Terrae in Sectione Omnibus [X] kV [Y]“ accenditur. In systematibus ubi punctum neutrum per bobinam Petersen (bobinam suppressionis arcus) ad terram connectitur, lucerna indicativa „Bobina Petersen Operatur“ etiam accenditur.Indicationes Voltmetri Monitoris Isolationis:Tensio phase
    01/30/2026
  • Modus operationis terre iunctae puncti neutralis pro transformatoribus retis electricitatis 110kV~220kV
    Dispositio modi operis terrae puncti neutralis pro transformatoribus rete electricitatis 110kV~220kV debet exigentias tolerationis insulationis puncti neutralis transformatorum complere, et simul conari ut impedimentum sequentiae nullae stationum transformationis fere immutatum maneat, dum certatur ne impedimentum sequentiae nullae compositum in quocumque puncto raptus circuiti systematis ultra ter impedimentum sequentiae positivae compositum excedat.Pro transformatoribus 220kV et 110kV in novis
    01/29/2026
  • Cur Quare Substationes Lapidem Gravem Calculos et Rupem Fractam Utuntur
    Cur Quare Substationes Utuntur Lapidibus, Gravibus, Piscinis et Saxis Tritis?In stationibus transformationis, instrumenta ut transformatores electricitatis et distributionis, lineae transmissionis, transformatores tensionis, transformatores currentis et commutatores disiunctionis omnia terram exigunt. Praeter terram, nunc profundius explorabimus cur gravia et saxa trita in stationibus transformationis saepe utuntur. Quamquam videantur ordinaria, isti lapides partem criticam iuxtaque functionalem
    01/29/2026
  • Cur autem nucleus transformatoris tantum in uno puncto terram tangere debet Nonne terra multipuncta fidelius est
    Cur ergo nucleus transformatoris terram tangere debet?In operatione, nucleus transformatoris, simul cum structuris, partibus et componentibus metallicis quae fixant nucleum et spiras, in forti campo electrico situs est. Sub influentia huius campi electrici, potentialem relativum altum ad terram comparatum acquirunt. Si nucleus non terra tangitur, differentia potentialis inter nucleum et structuras claudicantes et vas terratum existet, quae possit ad intermitterentiam dismissionem ducere.Praetere
    01/29/2026
  • Intellegere Terram Neutralis Transformatoris
    I. Quid est Punctum Neutrum?In transformatoribus et generatoribus, punctum neutrum est locus specificus in spira ubi absoluta tensio inter hunc locum et singula terminalia externa aequalis est. In diagrammate infra, punctumOrepraesentat punctum neutrum.II. Cur Punctum Neutrum Terrendum Est?Modus connexionis electricae inter punctum neutrum et terram in systemate AC triphasico diciturmodus terrendi puncti neutri. Hic modus directe afficit:Securitatem, fidem et oeconomiciam retelectrici;Selectione
    01/29/2026
Non invenisti adhuc opportunos fornitoris ut te inveniant Citationem Nunc Accipe
Non invenisti adhuc opportunos fornitoris ut te inveniant
Citationem Nunc Accipe
Inquiry
+86
Click to upload file
Descarica
Obtine Applicatio Commerciale IEE-Business
Utiliza app IEE-Business ad inveniendum apparatus obtinendumque solutiones coniungendum cum peritis et participandum in collaboratione industriale ubique et semper propter totam supportionem tuorum projectorum electricitatis et negotiorum