• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


484MVA/500kV GSU IEE-Business Generator Step-Up Transformer Nuclearis Plantae (Transformer pro generatione)

  • 484MVA/500kV GSU Generator Step-Up Transformer Nuclear Power Plant(Transformer for generation)

Attributa principalia

Marca ROCKWILL
Numerus Modeli 484MVA/500kV GSU IEE-Business Generator Step-Up Transformer Nuclearis Plantae (Transformer pro generatione)
Frequenta nominata 50/60Hz
Series GSU

Descriptiones productorum a fornitori

Descriptio

Descriptio

Transformator GSU (Generator Step-Up) ludit partem criticam in plantis nuclearibus ut dispositum electricum centrale, quod connectit generatores nucleares ad rete transmissionis. In planta, reactores nucleares producunt magnam energiam thermicam, quae per generatoria vaporis convertitur in vapor alti caloris et pressionis, qui movet turbines generatores et generat electricitatem. In hoc stadio, generator emittit medii-bassam tensionem alternantem (typice 10-20kV). Prima functio transformatoris GSU est hanc tensionem significanter augere ad niveles sicut 110kV, 220kV, vel superiores, ob satisfaciendum exigentiae longinquae transmissionis, capacitate magna, reducendo perditas durante transmissione, et permittendo integrationem efficientem nucleare in rete. Status operativus eius directe impingit stabilitatem et fiduciam output nuclearis, tamquam operationem securam et stabilam totius systematis electrici, faciens eum nodum clavem pro assecurando supply continuo et stabili ex plantis nuclearibus.

  • 1-Ph 484MVA/500kV

Characteristica

  • Ultra-High Reliability and Stability: Plantae nucleares habent exigentias operationales extremiter severas. Transformatores GSU utuntur laminae silici ferri alta permeabilitate pro core et cuprum sine oxygene purissimum pro windings, combinata cum processibus manufacturae et technologiis insulationis avant. Hoc assecurat operationem fidelam et stabilam sub oneribus altis longa tempore et servitio continuo, minuens riscos fallorum et interruendi generationem nuclearis. Sunt etiam instructi systematibus protectionis et monitoring redundantis, sicut dispositiva proteccionis relais multipli quae monitorant currentem, tensionem, et temperaturam real-time. Haec systemata agunt celeriter ad circuitos secantes in casu abnormalitatum, praeventes escalationem fallorum. Addito, sensoria intelligentia continenter sequuntur performance equipmenti, praebentes data supporto pro maintenance preventiva ad tenendum dispositivum in conditione optimale.

  • Robustitas Fortis contra Circuitos Breves: Rete interna plantarum nuclearium est complexa, et falli circuiti brevis possunt occurrere sub conditionibus abnormalibus, generantes currents circuiti brevis fortes et vires electromagneticas. Transformatores GSU habent windings specialiter volutas ad robur mechanicum et stabilitatem inter windings augmentandam, permitentes eos efficaciter sustinere impactum fortem virium electromagneticarum durante circuitis brevibus. Hoc maintinet integritatem structuralem, assecurat securitatem transformatoris, et evitat consequentias graves sicut damnum equipmenti vel etiam shutdowns plantarum nuclearium causatas ab circuitis brevibus.

  • Adaptabilitas ad Environments Duris: Plantae nucleares habent ambientes internos complexos cum factoribus sicut radiation, alti calores, alti humiditates, et corrosiones chemicae. Transformatores GSU sunt designati cum enclosures excellenti performance shielding ad efficaciter radiationem obturandam et protectendam componentes electricos internos. Utuntur materialibus insulatoribus et coatingibus protective alti caloris, humido, et corrosionis resistentibus, assecurantes performance insulatoriam stabilem in ambientibus alti caloris et humiditatis. Hoc praevent issues sicut aging insulatorium vel circuiti brevis causatas ab factoribus environmentalibus, garantens operationem normalem longa tempore in conditionibus duris plantarum nuclearium.

  • Capacitas Magna et Compatibilitas Altior Tensionis: Cum capacitate generationis plantarum nuclearium continue crescendo, demandae pro capacitate et niveles tensionis transformatorum GSU sunt incrementae. Hi transformatores typice offerunt capacitatem plurium centiarum MVA vel superior, cum niveles tensionis quae congruunt requirementibus connectionis ad rete—step-up ab decimis kV ad 110kV, 220kV, vel superiores. Hoc permittit transmissionem efficientem scalae magnae nuclearem, satisfaciendo necessitates magnas electricitatis societatis.

  • Perdita Parva et Efficacia Energiae: Inter crescentem emphasis super utilisationem energiae et protectionem environmental, transformatores GSU pro plantis nuclearibus focus ponunt super minimizandum perditarum. Per structures core optime et designs winding meliore, reducunt perditarum core hysteresis et winding resistance, augmentantes efficaciam conversionis energiae. Hoc demittit costus generationis, reducit perditas energiarum superfluarum et emissiones carbonis, et congruit conceptis developmentis virentis.

Cognosce tui fornitori
Venditio Online
Ratio praestabilitae tradendae
Tempus responsionis
100.0%
≤4h
Brevis Descriptio Societatis
Locus Operis: 108000m²m² Numerus omnium laborantium: 700+ Summa Annua Exportatio (USD): 150000000
Locus Operis: 108000m²m²
Numerus omnium laborantium: 700+
Summa Annua Exportatio (USD): 150000000
Servitia
Genus Negotii: Design/Fabricatio/Venditio
Categorias Principales: apparatus electrum altum voltus/transformator
Gubernatio vitae
Servitia gestionis curae integralis pro quaestu, usu, conservatione et post-venditionem apparatus electricorum, securitatem operationis, continuationem imperii et usum electricitatis sine cura garantia.
Fornitori instrumentorum praeteritus est certificationem qualificationis platformae et iudicium technicum, ut ex fonte conformitas, professionalitas et fiducia servantur.

Producta Connexa

Cognitio Connexa

  • Culpae et Tractatio Terrae Unipolaris in Lineis Distributionis 10kV
    Characteristica et Instrumenta Detegendi Defectus Terrae Monofasiales1. Characteristica Defectuum Terrae MonofasialiumSigna Centralia Admonitionis:Campanula admonitionis sonat, et lucerna indicativa inscripta „Defectus Terrae in Sectione Omnibus [X] kV [Y]“ accenditur. In systematibus ubi punctum neutrum per bobinam Petersen (bobinam suppressionis arcus) ad terram connectitur, lucerna indicativa „Bobina Petersen Operatur“ etiam accenditur.Indicationes Voltmetri Monitoris Isolationis:Tensio phase
    01/30/2026
  • Modus operationis terre iunctae puncti neutralis pro transformatoribus retis electricitatis 110kV~220kV
    Dispositio modi operis terrae puncti neutralis pro transformatoribus rete electricitatis 110kV~220kV debet exigentias tolerationis insulationis puncti neutralis transformatorum complere, et simul conari ut impedimentum sequentiae nullae stationum transformationis fere immutatum maneat, dum certatur ne impedimentum sequentiae nullae compositum in quocumque puncto raptus circuiti systematis ultra ter impedimentum sequentiae positivae compositum excedat.Pro transformatoribus 220kV et 110kV in novis
    01/29/2026
  • Cur Quare Substationes Lapidem Gravem Calculos et Rupem Fractam Utuntur
    Cur Quare Substationes Utuntur Lapidibus, Gravibus, Piscinis et Saxis Tritis?In stationibus transformationis, instrumenta ut transformatores electricitatis et distributionis, lineae transmissionis, transformatores tensionis, transformatores currentis et commutatores disiunctionis omnia terram exigunt. Praeter terram, nunc profundius explorabimus cur gravia et saxa trita in stationibus transformationis saepe utuntur. Quamquam videantur ordinaria, isti lapides partem criticam iuxtaque functionalem
    01/29/2026
  • Cur autem nucleus transformatoris tantum in uno puncto terram tangere debet Nonne terra multipuncta fidelius est
    Cur ergo nucleus transformatoris terram tangere debet?In operatione, nucleus transformatoris, simul cum structuris, partibus et componentibus metallicis quae fixant nucleum et spiras, in forti campo electrico situs est. Sub influentia huius campi electrici, potentialem relativum altum ad terram comparatum acquirunt. Si nucleus non terra tangitur, differentia potentialis inter nucleum et structuras claudicantes et vas terratum existet, quae possit ad intermitterentiam dismissionem ducere.Praetere
    01/29/2026
  • Intellegere Terram Neutralis Transformatoris
    I. Quid est Punctum Neutrum?In transformatoribus et generatoribus, punctum neutrum est locus specificus in spira ubi absoluta tensio inter hunc locum et singula terminalia externa aequalis est. In diagrammate infra, punctumOrepraesentat punctum neutrum.II. Cur Punctum Neutrum Terrendum Est?Modus connexionis electricae inter punctum neutrum et terram in systemate AC triphasico diciturmodus terrendi puncti neutri. Hic modus directe afficit:Securitatem, fidem et oeconomiciam retelectrici;Selectione
    01/29/2026
  • Quid est Differentia Inter Transformatores Rectificatores et Transformatores Potentiae?
    Quid est transformator rectificans?"Conversio potentiae" est terminus generalis qui conversionem, inversionem et conversionem frequentiae comprehendit, inter quas conversio praecipue usitatissima est. Apparatus rectificans convertit potentiam AC input in DC output per rectificationem et filtrationem. Transformator rectificans servit ut transformator alimentationis pro talibus apparatibus rectificantibus. In applicationibus industrialibus, plerumque alimenta DC obtinentur per combinandum transfor
    01/29/2026

Solutiones Relatae

  • Design Solution of 24kV Siccum Aera Insulatum Ring Main Unit
    Combinatio Solidi Insulationis Adiuvantis + Insulationis Aereae Siccae repraesentat directionem pro RMU 24kV. Per requirementa insulationis cum compactitate equilibrata et adiuvante solidum insulationis, testes insulationis sine magnificatione significativa dimensionum inter phasos et inter phasos et terram transigi possunt. Inclusio columnae pole solidificat insulationem pro interruptore vacuo et conductoribus eius coniunctis.Maintinendo spatium phasorum exiens 24kV ad 110mm, intensitas electri
    08/16/2025
  • Optimizatio Design Schematum pro Unitate Circulorum Principalium Aere Insulata 12kV ad Minuendam Probabilitatem Disruptionis Emissionis
    Cum celeri progressus industriae electricitatis, conceptus ecologicus de carbonis minore, energiae servanda, et conservatione ambientis profundissime integratus est in designum et fabricam productorum electricorum pro distributione et generatione electricitatis. Unitas Distributiva Circuli (RMU) est dispositivum electricum clavem in retibus distributionis. Securitas, conservatio ambientis, fides operativa, efficacia energetica, et oeconomia sunt tendentiae inevitabiles in eius progressu. RMUs tr
    08/16/2025
  • Analyse communium problematum in unitatibus principali circuitu isolatis gas 10kV (RMUs)
    Introductio:​​RMUs insulati gaseis 10kV sunt amplissime usitati propter multas suas utilitates, sicut quod sint perfecte clausi, habeant excellentem insulativam qualitatem, non requirant maintenance, sint compacti, et praebent installationem flexibilem et commodam. In hoc stadio, paulatim facti sunt nodus criticus in rete distributionis urbano anulari et iocabuntur partem significativam in systemate distributionis electricitatis. Difficultates in RMUs insulatis gaseis possunt graviter impingere
    08/16/2025
Instrumenta Libera Cognata
Non invenisti adhuc opportunos fornitoris ut te inveniant Citationem Nunc Accipe
Non invenisti adhuc opportunos fornitoris ut te inveniant
Citationem Nunc Accipe
Inquiry
+86
Click to upload file
Descarica
Obtine Applicatio Commerciale IEE-Business
Utiliza app IEE-Business ad inveniendum apparatus obtinendumque solutiones coniungendum cum peritis et participandum in collaboratione industriale ubique et semper propter totam supportionem tuorum projectorum electricitatis et negotiorum