| Muhimmiya | Vziman |
| Model NO. | 35kV ɗaya mai zama da kuma mai zama a cikin babban gida |
| Rated Frequency | 50/60Hz |
| Karma voltaji | 2400-34,500 V |
| Vọltiji na bi gaba | 120-600 V |
| Ga gwamnati na IEE-Business | 10-167 kVA |
| Siri | ZGS |
Descripton:
A cikin manyan hanyoyi na farko da mafi yawan zama, masu kwalba a cikin tashar muhimmiyar suka shahara da kyau saboda ingancin al'adu, kayan aiki, kadan aiki, da kuma amninsu. Wannan masu kwalba suna amfani da mai maye FR3 ta fiye, wanda ya ba su damar hanyoyi mai kyau. Idan a tuntubi da masu kwalba na minira, rike daɗi a yi aiki a kan su ya ci gaba sosai. Kadan aiki na wannan masu kwalba ta kasancewa 10 zuwa 167 kVA, kuma ana iya samun su a wurare da dama kamar ANSI Type 1, ANSI Type 2, da Ranch Runner, wanda ke sa su daidai a wurare da dama.
Mai maye FR3 ba ni biodegradable ko duk fuskantar jiki, amma ya ba damar aiki mai kyau a kan adadin da ake tabbata. Wannan mai maye ta dogara da takardun ASTM D6871-03 da kuma PC57.147 IEEE wanda ake magana a kan shi.
Dammar aiki na baki daya ya kai ko ya kudacewa takardun da ma'aikatun da dama, ciki har da ANSI (babu Ranch Runner), NEMA, da kuma takardun kayan aiki na DOE.
Karkashin da kuma kwalban su ne suka gina da kalmomi don ba su damar amninsu da kuma hada da kwallon aiki a kan gwamnati. Ana bayar da zaɓu a kan abubuwan kaya, kamar kaya na grain-oriented steel da kuma amorphous steel.
Ingancin aiki na hanyoyi ya kunshi Bay-O-Net fuses domin shi, amma akwai zaɓu a kan fuses na current-limiting ko kuma weak link components don bayar da tsari.
Gwamnatin da kuma kwalban su ne suka tafin tsiro, wanda zai iya haɗa da kalamai na aluminum ko copper don ba su damar aiki mai kyau.
Technical Parameters:


Maye da kai ko ya kudace takardun ANSI, NEMA da DOE2016
IEEE standards C57.12.00, C57.12.38, C57.12.28, C57.12.35, C57.12.90, C57. 91 and C57.154
Takardun NEMA, NEMA TR 1 (R2000)
Department of Energy Efficiency Standard, 10 CFR Part 431
Tank coating exceeds IEEE Std C57.12.28-2005 and C57.12.29-2005 standards (stainless steel units only)
Full compliance with IEEE Std C57.12.28-2005 standard enclosure integrity requirements
FR3 fluid
Cores and coils designed for high reliability and low field failure rates: Available in grain-oriented electrical or amorphous steel
The transformer shall be designed in accordance with this specification and shall have an Average Winding Rise (AWR) of one of the following:
55 °C, 55/65 °C, 65 °C
The applicable AWR rating shall be specified on the inquiry
The transformer shall be designed in accordance with this specification and shall have one of the following kVA ratings:
10, 15, 25, 37.5, 50, 75, 100, 167
The applicable kVA rating shall be specified on the inquiry
Quality System ISO 9001 certified