Cable ignifugum armatum cum isolatione ex polyethyleno cross-linkato (XLPE) 26/35kV

  • 26/35kV Fire-Resistant Armored Cable with Cross-Linked Polyethylene (XLPE) Insulation

Attributa principalia

Marca Wone Store
Numerus Modeli Cable ignifugum armatum cum isolatione ex polyethyleno cross-linkato (XLPE) 26/35kV
Votum nominatum 26/35kV
Frequenta nominata 50/60Hz
Series NH-YJV

Descriptiones productorum a fornitori

Descriptio

Descriptio Producti

Cable YJV est species cable electricitatis maxime communis, et adhuc multi homines de cabledicunt generaliter YJV cables. Quasi arteria in sanguine humano vel trunci arboris, cable YJV, ut columna dorsalis in transmissione electricitatis, ostendit locum suum importantem in transmissione electricitatis. Cables YJV saepe inveniuntur in passage subterraneis urbium (sub operibus foraminis) aut sepulti sub terra, et saepe constructores effodiunt cables electricitatis in constructione, quod facit accidentia magnae amplitudinis intermissionis electricitatis, quod est cable electricitatis. Hic sunt breves introductiones ad cables YJV:
 
Nomen producti plenum
cable electricitatis cum corde cupreus (aluminis) insulato polyethyleno cross-linkato et sheatho polyvinylchloridano;
 
Structura producti
Componentes cable YJV ab intus ad extus sunt conductores, insulatores polyethyleni, repletores (nylon, composita PVC, etc.), sheatho externo PVC,
Inter quos, conductores saepissime sunt cordes cuprei, et nunc, conductores cuprei sunt materiae conductoris maxime usitatae in mercatu, conductores aluminis minus usantur propter conductivitatem malam et defectum standardum; Repletoria saepius sunt nylon et alia materia, quae munus habent protegendi cor wire, quod est equivalent ad ponendum "vestimentum" ad cor cable; Si est cable armatus, addetur stratum armoris ferri inter repletoria et sheathum, scopus est ut cable sit sepultus in terra ad agendum muni contra pressionem, et modello cable YJV armatus ferro est YJV22; Sheatho PVC est materia PVC nostra communis.
Standardes executionis producti
GB/T12706.1-2008, IEC60502-1-1997 standardes
Materia conductoris
materia cuprea et materia aluminii alloy, inter quas, codex modello cable core aluminis est YJLV;
Voltage nominale
Cables YJV dividuntur generaliter in quattuor species: ultra alta tensio, alta tensio, media tensio, et bassa tensio, et maxime usitati sunt cables bassae tensionis, alta et ultra alta tensio generaliter utuntur ad longinquam et ultra longinquam transmissionem electricitatis, media et bassa tensio cables electricitatis (35 kilovolts et infra).
Temperatura
Maxima temperatura longa permittenda operativa conductoris cable est 70°C, quando conductoris cable est circuitus breve (maxima duratio non superat 5S), maxima temperatura conductoris cable non superat 160°C, et temperatura ambientis quando ponitur cable non debet esse infra 0°C.
Usus
cables electricitatis ingeniorum distributionis electricitatis, cables electricitatis ingeniorum transmissionis electricitatis, cables ingeniorum installationis electromechanicae et hydraulicae, cables transmissionis electricitatis, systemata controlis systemationum installationis electricitatis, etc
Cautela installationis
Radius flectens minimus non minor decies diametro externo cable quando poni cable, et cable YJV/YJLV poni potest intus, in canali et tubo, aut potest sepeli in terra lassa, et non potest sustinere actionem vis externarum. Cables YJV22/YJLV22 poni possunt sub terra et possunt sustinere vires mechanicas externas, sed non possunt sustinere magnas vires tractionis. Instrumenta specialia uti debentur ad ponendum cable, sicut frames pay-off, rotulis directoribus, etc., ut preveniant damnum mechanicum in processu positionis et discedant a fontibus caloris. Quando cable pergit per tubum, diameter internus tubi non minor est quam unum et dimidium diametri externi puncti, et cable prohibetur premi quando cable transigitur, et area totalis cable non superat 40% areae totalis in tubo.
Classificatio producti cable YJV: species ordinaria, species retardans flammam, species ignifuga, species fumigene halogen-free
Modello speciei
Cable YJV potest esse singulus, aut multi conductores simul, numerus nuclei cable YJV est nucleus singulus, 2 nucleus, 3 nucleus, 4 nucleus, 5 nucleus, 3+1 nucleus, 3+2 nucleus, 4+1 nucleus, etc., inter quos 3+1 nucleus, 3+2 nucleus, 4+1 nucleus constat duobus conductoribus diversis officiis, unus vocatur filum phase, alter vocatur filum terrae, est specialiter terrae. Specificationes communiter usitatae sunt 1mm², 1.5mm², 2.5mm², 4mm², 6mm², 10mm², 16mm², 25mm², 35mm², 50mm², 70mm², 95mm², 120mm², 150mm², 185mm², 240mm², 300mm², etc., sicut cable YJV3*185+2*95 constat 3 185mm² filis phase et 2 95mm² filis terrae.
Cognosce tui fornitori
Venditio Online
Ratio praestabilitae tradendae
Tempus responsionis
100.0%
≤4h
Brevis Descriptio Societatis
Locus Operis: 1000m² Numerus omnium laborantium: Summa Annua Exportatio (USD): 300000000
Locus Operis: 1000m²
Numerus omnium laborantium:
Summa Annua Exportatio (USD): 300000000
Servitia
Genus Negotii: Venditio
Categorias Principales: transformator/pars componentium/cable et filum/Energia nova/Instrumenta inspectionis/apparatus electrum altum voltus/Aedificii electritas Apparatus electricus/Apparatus electri bassa tensione/Instrumenta et mensurae/Instrumenta productiva/aestus apparatus/Ferramentae electricitatis
Gubernatio vitae
Servitia gestionis curae integralis pro quaestu, usu, conservatione et post-venditionem apparatus electricorum, securitatem operationis, continuationem imperii et usum electricitatis sine cura garantia.
Fornitori instrumentorum praeteritus est certificationem qualificationis platformae et iudicium technicum, ut ex fonte conformitas, professionalitas et fiducia servantur.

Producta Connexa

Cognitio Connexa

  • Accidentia Transformatoris Principalis et Questiones Operationis Gas Luminis
    1. Registri accidentis (XIX Martii, MMXIX)Hora XVI:XIIX die XIX Martii, MMXIX, monitorium background reportavit actionem gas levis transformatoris principis numeri III. Conformiter Codex Operationis Transformatorum Electricitatis (DL/T572-2010), personale operationis et maintenance (O&M) inspectavit statum in situ transformatoris principis numeri III.Confirmatio in situ: Panel non-electricus protectionis WBH transformatoris principis numeri III reportavit actionem gas levis phase B corpus tr
    02/05/2026
  • Culpae et Tractatio Terrae Unipolaris in Lineis Distributionis 10kV
    Characteristica et Instrumenta Detegendi Defectus Terrae Monofasiales1. Characteristica Defectuum Terrae MonofasialiumSigna Centralia Admonitionis:Campanula admonitionis sonat, et lucerna indicativa inscripta „Defectus Terrae in Sectione Omnibus [X] kV [Y]“ accenditur. In systematibus ubi punctum neutrum per bobinam Petersen (bobinam suppressionis arcus) ad terram connectitur, lucerna indicativa „Bobina Petersen Operatur“ etiam accenditur.Indicationes Voltmetri Monitoris Isolationis:Tensio phase
    01/30/2026
  • Modus operationis terre iunctae puncti neutralis pro transformatoribus retis electricitatis 110kV~220kV
    Dispositio modi operis terrae puncti neutralis pro transformatoribus rete electricitatis 110kV~220kV debet exigentias tolerationis insulationis puncti neutralis transformatorum complere, et simul conari ut impedimentum sequentiae nullae stationum transformationis fere immutatum maneat, dum certatur ne impedimentum sequentiae nullae compositum in quocumque puncto raptus circuiti systematis ultra ter impedimentum sequentiae positivae compositum excedat.Pro transformatoribus 220kV et 110kV in novis
    01/29/2026
  • Cur Quare Substationes Lapidem Gravem Calculos et Rupem Fractam Utuntur
    Cur Quare Substationes Utuntur Lapidibus, Gravibus, Piscinis et Saxis Tritis?In stationibus transformationis, instrumenta ut transformatores electricitatis et distributionis, lineae transmissionis, transformatores tensionis, transformatores currentis et commutatores disiunctionis omnia terram exigunt. Praeter terram, nunc profundius explorabimus cur gravia et saxa trita in stationibus transformationis saepe utuntur. Quamquam videantur ordinaria, isti lapides partem criticam iuxtaque functionalem
    01/29/2026
  • Cur autem nucleus transformatoris tantum in uno puncto terram tangere debet Nonne terra multipuncta fidelius est
    Cur ergo nucleus transformatoris terram tangere debet?In operatione, nucleus transformatoris, simul cum structuris, partibus et componentibus metallicis quae fixant nucleum et spiras, in forti campo electrico situs est. Sub influentia huius campi electrici, potentialem relativum altum ad terram comparatum acquirunt. Si nucleus non terra tangitur, differentia potentialis inter nucleum et structuras claudicantes et vas terratum existet, quae possit ad intermitterentiam dismissionem ducere.Praetere
    01/29/2026
  • Intellegere Terram Neutralis Transformatoris
    I. Quid est Punctum Neutrum?In transformatoribus et generatoribus, punctum neutrum est locus specificus in spira ubi absoluta tensio inter hunc locum et singula terminalia externa aequalis est. In diagrammate infra, punctumOrepraesentat punctum neutrum.II. Cur Punctum Neutrum Terrendum Est?Modus connexionis electricae inter punctum neutrum et terram in systemate AC triphasico diciturmodus terrendi puncti neutri. Hic modus directe afficit:Securitatem, fidem et oeconomiciam retelectrici;Selectione
    01/29/2026

Solutiones Relatae

  • Integrata Solutio Potentiae Mixtae Ventus-Solaris pro Insulis Remote
    AbstractusHoc propositum praebet solutionem integratam energetica innovativam, quae profunde combinet generationem venti, photovoltaicam, accumulationem hydroelectricam et desalinizationem marina. Id intendit systematica adflictiones corde insularum remotarum solvere, inter quas difficultates coperturae rete, costus alti generationis diesel, limitationes accumulationis battery traditionalis et raritas fontium aquarum dulcium. Haec solutio synergiarum et autonomiae in "supply power - energy stora
    10/17/2025
  • Systema Hybridum Ventus-Solar cum Controllo Fuzzy-PID pro BATTERIAE GESTIONE ENHANCED et MPPT
    AbstractusHoc propositum systema generationis electricitatis mixtum venti-solaris praebet, quod superiore technologia controlis innititur, ad efficaciter et oeconomico satisfaciendum indigentiis electricitatis regionibus remotis et scenariis applicationis specialibus. Nucleus huius systematis in systemate intelligenti controlis centrat, quod circa microprocessorem ATmega16 constat. Hoc systema Maximum Power Point Tracking (MPPT) tam venti quam solaris perficit et algorithmo optimato, qui combini
    10/17/2025
  • Solutio Mixta Venti-Solis Costo-Effectivus: Convertor Buck-Boost et Caricatio Intelligens Reducunt Costum Systematis
    AbstractHoc solutio novum systema generationis potestatis venti-solaris altae efficientiae proponit. Ad corrigendum defectus in technologiis existentibus, sicut usus parvus energiae, brevis vita bateriarum, et infirma stabilitas systematis, hoc systema convertes DC/DC buck-boost digitaliter plene controlatos, technologiam parallelam interlaced, et algorithmum intelligentem tristagium caricationis adhibet. Hoc permittit Maximum Power Point Tracking (MPPT) in latiore ambitu velocitatum venti et ir
    10/17/2025
Non invenisti adhuc opportunos fornitoris ut te inveniant Citationem Nunc Accipe
Non invenisti adhuc opportunos fornitoris ut te inveniant
Citationem Nunc Accipe
Inquiry
+86
Click to upload file
Descarica
Obtine Applicatio Commerciale IEE-Business
Utiliza app IEE-Business ad inveniendum apparatus obtinendumque solutiones coniungendum cum peritis et participandum in collaboratione industriale ubique et semper propter totam supportionem tuorum projectorum electricitatis et negotiorum