• 15KVA - 250KVA Single phase Pad mounted Transformer
15KVA - 250KVA Single phase Pad mounted Transformer
discuss personally
Model
SPM-15/250kVA
Basic info
Brand POWERTECH
Model NO. 15KVA - 250KVA Single phase Pad mounted Transformer
Rated capacity 250kVA
Series SPM
Product Detail

Description

A single-phase pad-mounted transformer is a compact, ground-level electrical distribution unit designed for residential and light commercial applications. With a standard capacity range of 15–250 kVA, it efficiently steps down voltage to supply single-phase power for household appliances, lighting, and other everyday electrical loads.

These transformers are commonly installed in areas where three-phase power is unnecessary, offering a cost-effective and space-saving solution compared to larger three-phase models. Their enclosed, tamper-resistant design ensures safety and reliability while blending discreetly into urban and suburban environments.

Feature

Core & Construction

  • Core-type design with rectangular silicon steel laminations for optimal magnetic performance  

  • Layer-wound copper windings for enhanced conductivity and efficiency  

Performance Specifications

  • Rated capacity: 15-250kVA (standard range covers 15-250kVA for residential use)  

  • Low noise operation: ≤50dB for minimal environmental disturbance

  • Dual frequency compatibility: 50Hz/60Hz for versatile applications

Safety & Reliability

  • Overcurrent protection integrated for equipment and grid safety

  • Natural heat dissipation design eliminates need for auxiliary cooling systems   

Certifications & Compliance

  • Meets international standards: ISO9001, CCC, and CE certified  

  • Green enclosure with tamper-resistant construction

Customization & Logistics

  • OEM services available with customizable specifications

  • Sturdy packaging options: iron or wooden cases for secure transportation

Parameters

 

Structure diagram

 

Know your supplier
POWERTECH
We are an electrical company that manufactures and sells high and low voltage electrical products.
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$120000000
Professional Experience
7 years
Workplace
580000m²
占位
占位
Related Products
Related Knowledges
Why are the ground fault point and the accident point not at the same location?
Why are the ground fault point and the accident point not at the same location?
Fault Transfer VoltageIn low - voltage distribution systems, there is a type of personal electric shock accident where the accident occurrence point and the system fault point are not at the same location. This kind of accident occurs because after a ground fault happens elsewhere, the generated fault voltage is conducted to the metal casings of other equipment through the PE wire or PEN wire. When the fault voltage on the metal casing of the equipment is higher than the human - body safe voltag
Leon
07/18/2025
Analysis of Transformer Capacity, Load Rate and Number of Units Selection Issues
Analysis of Transformer Capacity, Load Rate and Number of Units Selection Issues
The safe and economical operation of power transformers is related to the safety, economy, stability, and reliability of the operations of various industries. The limitations of conditions such as the investment economic indicators for its selection, the economic benefits of maintenance and operation, and the adaptability in the new environment (access of distributed power sources, configuration of energy storage, etc.) make it impossible to include comprehensive factors in other aspects.The cap
Leon
07/17/2025
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
1 IntroductionLow - voltage current transformers for metering, with a through - core type epoxy resin structure, are widely used in distribution transformer areas and for small - to - medium - sized industrial and commercial electricity consumption. As a range expander for electric energy metering, their performance directly relates to electricity consumption safety and the accuracy of users' trade calculations. Studying long - term immersion's impact on these transformers is practically signifi
Felix Spark
07/17/2025
What is reactive power measurement?
What is reactive power measurement?
The power which exists in the circuit when the voltage and current are out of phase to each other, such type of power is known as the reactive power. The formula measures the reactive power in the circuitReactive Power Measurement & VarmetersReactive power measurement is critical as it indicates circuit power loss: low reactive power worsens load power factor, increasing system losses. Varmeters (volt-ampere reactive meters) measure reactive power and are categorized by circuit phases:Single
Edwiin
07/17/2025
How to Design and Install a Solar PV System?
How to Design and Install a Solar PV System?
Design and Installation of Solar PV SystemsModern society relies on energy for daily needs like industry, heating, transport, and agriculture, mostly met by non-renewable sources (coal, oil, gas). However, these cause environmental harm, are unevenly distributed, and face price volatility due to limited reserves—driving demand for renewable energy.Solar energy, abundant and capable of meeting global needs, stands out. Standalone PV systems (Fig 1) offer energy independence from utilities.
Edwiin
07/17/2025
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
Low-voltage current transformers, as indispensable measurement and protection devices in power systems, often encounter various faults when used in combination with other power equipment due to environmental factors, equipment linkage issues, and improper installation and maintenance. These faults not only affect the normal operation of power equipment but may also endanger personal safety. Therefore, it is necessary to gain an in-depth understanding of fault types, judgment methods, and prevent
Felix Spark
07/17/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!