Reclosor automatis circuituum vacuum exterioris mediae tensionis 15kV/1250A

  • 15kV/1250A MV outdoor vacuum Auto Circuit recloser
  • 15kV/1250A MV outdoor vacuum Auto Circuit recloser
  • 15kV/1250A MV outdoor vacuum Auto Circuit recloser

Attributa principalia

Marca ROCKWILL
Numerus Modeli Reclosor automatis circuituum vacuum exterioris mediae tensionis 15kV/1250A
Votum nominatum 15kV
currus electricus nominatus 400A
currentis rumpendi nominale in circuitu commutato 12.5kA
Tensio sustentans frequentia industriale 36kV/min
Voltage tolerabile impulsum fulminis nominale 110kV
Manuale clausura Yes
claustra mechanicum
Series RCW

Descriptiones productorum a fornitori

Descriptio

Describtiō :

Sēriēs RCW automātiski circuit reclosers possunt adhiberi in lineīs distribūtiōnis super capitibus tamquam in applicationibus substationum distribūtiōnis pro omnibus classibus voltaginum ab 11kV usque ad 38kV in systemate electricitatis 50/60Hz. Et currentus eius nominālis potest attingere 1250A. Sēriēs RCW reclosers integrat functiones controlis, protectionis, mensurandī, communicationis, detectionis fault, on-line monitoring clausūrum aut apertūrum. Sēriēs RCW vacuum recloser prae ceteris combinatur cum integratione termināle, current transformer, permanent magnetic actuator et recloser controller.

Characteristicae :

  • Gradus optionales disponibiles in ambitu currentus nominālis.

  • Cum protectione relē et logica pro selectione usoris.

  • Cum protocolis communicationis et portis I/O pro electione usoris.

  • Software PC pro testationem, setup, programmationem, updates controlleris.

Parametri

image.png

image.png


Requisita ambientalia :

image.png

Demonstratio producti :

不代手合正方形硅橡胶永磁.png

带手合正方形 硅橡胶永磁带手合.png

Quid est extinguendi arcuum vacuum defectus foras vacuum recloser et solutio eius?

Defectus Camerae Extinguendi Arcuum Vacuum :

  • Vacuum Level Decreased: Hoc est problema communiter in camerae extinguendi arcuum vacuum. Camera huiusmodi dependet de ambientes vacuum altissimo ad extinguendum arcus. Si level vacuum diminuitur, performance insulationis et facultas extinguendi arcus significanter deteriorantur. Causae diminutionis vacuum includunt sealing malam, sicut materiale sealing vetustum vel damnum, vel parvulas fugas presentes in processu manufacturae. Cum level vacuum declinet ad certum punctum, incomplete extinguendo arcus potest occurrere interrupcionis currentis, ducens ad rekindling arcus et subsequentes lineae defectus.

  • Usus Contactorum: In frequentibus operationibus aperiendi et claudendi, contacti camerae extinguendi arcuum vacuum possunt consumi per erosionem arcuum. Consumptio contactorum auget resistenciam contactorum, quod potest ducere ad severum calefactionem contactorum quando currentus normalis transit, affectans operationem normalem equipmenti. Praeterea, interrupcio currentis fault, contacti non possunt sustinere currentem altum, resultante welding contactorum vel failure interrupcionis currentis.

Solutio Defectus Camerae Extinguendi Arcuum Vacuum :

Decrease Vacuum Level :

  • Detectare Level Vacuum: Utere instrumentis specialibus detectandi level vacuum, sicut testeris level vacuum, ad regulariter inspectandum level vacuum camerae extinguendi arcuum vacuum. Quod level vacuum invenitur esse infra valor specificatus, camera extinguendi arcuum vacuum debet prompte substitui.

  • Substituere Seals: Si suspectas sealing malam causare diminutionem level vacuum, inspecta et substitue seals. Substitutione seals, assecura ut utaris materialibus sealing qualitatibus altis et compatibilibus et sequaris correctos proceduras installationis ad praeventionem ulterioris leakage.

Usus Contactorum :

  • Inspectiones Regulariter: Inspecta regulariter conditionem usus contactorum per fenestras observationis vel dissecando dispositivum. Consecutim, si usus excedit limites specificatos, contacti debent prompte substitui.

  • Optimizare Parametros Operationis: Analyza causas usus contactorum, sicut an sit propter operationes frequentes vel currentem operationis excessivum. Si problema est operationes frequentes, considera optimizare strategiam reclosing reclosoris ad reducendum operationes aperiendi et claudendi inutilis. Si problema est currentem operationis excessivum, inspice conditions load lineae, ajusta settings protectionis, et evita subjecting contactorum ad impactus currentis excessivi.


Cognosce tui fornitori
Venditio Online
Ratio praestabilitae tradendae
Tempus responsionis
100.0%
≤4h
Brevis Descriptio Societatis
Locus Operis: 108000m²m² Numerus omnium laborantium: 700+ Summa Annua Exportatio (USD): 150000000
Locus Operis: 108000m²m²
Numerus omnium laborantium: 700+
Summa Annua Exportatio (USD): 150000000
Servitia
Genus Negotii: Design/Fabricatio/Venditio
Categorias Principales: apparatus electrum altum voltus
Gubernatio vitae
Servitia gestionis curae integralis pro quaestu, usu, conservatione et post-venditionem apparatus electricorum, securitatem operationis, continuationem imperii et usum electricitatis sine cura garantia.
Fornitori instrumentorum praeteritus est certificationem qualificationis platformae et iudicium technicum, ut ex fonte conformitas, professionalitas et fiducia servantur.

Producta Connexa

Cognitio Connexa

Solutiones Relatae

Non invenisti adhuc opportunos fornitoris ut te inveniant Citationem Nunc Accipe
Non invenisti adhuc opportunos fornitoris ut te inveniant
Citationem Nunc Accipe
Inquiry
Descarica
Obtine Applicatio Commerciale IEE-Business
Utiliza app IEE-Business ad inveniendum apparatus obtinendumque solutiones coniungendum cum peritis et participandum in collaboratione industriale ubique et semper propter totam supportionem tuorum projectorum electricitatis et negotiorum