126kV 138kV 145kV High-voltage AC Dead tank SF6 circuit breaker

  • 126kV 138kV 145kV High-voltage AC Dead tank SF6 circuit breaker

Key attributes

Brand ROCKWILL
Model NO. 126kV 138kV 145kV High-voltage AC Dead tank SF6 circuit breaker
Rated voltage 126kV
Rated normal current 3150A
Rated frequency 50/60Hz
Series LW

Product descriptions from the supplier

Description

Description

We are the pioneer in China's GIS tank circuit breaker industry and the country's first source factory specializing exclusively in this field.Outdoor 126kV High-voltage AC  Dead tank SF6 circuit breaker is an outdoor - installed, three - pole, 50Hz AC high - voltage switching device that uses SF6 gas as the arc - extinguishing and insulating medium. It can be used to interrupt and close rated current and fault current, interrupt and close capacitor banks, transfer circuits, and also be used as a tie - circuit breaker to achieve the control and protection of power transmission and transformation lines and equipment. It is especially suitable for frequent operations. The circuit breaker is equipped with a spring operating mechanism.

Main Features

The material of the contact end is copper - tungsten alloy, which has strong arc - resistance ability. Especially during the opening and closing process of the circuit breaker, an arc will be generated, and a large amount of energy acts on the arcing contacts. Therefore, the ablation - resistant material is an important guarantee for the electrical life. The large and small nozzles are made of polytetrafluoroethylene material with excellent high - temperature and arc - resistance properties and appropriate fillers.

Technical specifications

Among these, some SF6 tank circuit breakers cover non-standard voltage levels including 138kV, 225kV, 230kV, 245kV, 275kV, 330kV, 345kV, 400kV, 756kV, and 800kV with a rated short-circuit breaking current of 50kA or 63kA, and we offer customization services.

Rated Voltage

kV

126kV 138kV 145kV

Rated Current

A

3150A 4000A

Rated Frequency

Hz

50/60

First - Pole - To - Clear Factor

/

1.5

Rated Short - circuit Breaking Current

kA

40

Rated Short - time Withstand Current (Effective Value)

kA/s

40/4

Rated Peak Withstand Current

kA

100

Rated Power - frequency Withstand Voltage

Phase - to - phase/Ground

kV

230

Break - port

230(+73)

Rated Lightning Impulse Withstand Voltage (1/250μs Peak Value)

Phase - to - phase/Ground

550

Break - port

550(+103)

SF₆ Gas (Gauge Pressure, 20℃)

Rated Gas Pressure

Mpa

0.60

Alarm Gas Pressure

0.55±0.015

Lock - out Gas Pressure

0.50±0.015

Rated Operating Sequence

/

O - 0.3s - CO - 180s - CO

Rated Out - of - step Breaking Current

kA

10

Short - line Fault Breaking Current

kA

L90:36, L70:28

Asymmetrical - Phase Ground Fault Breaking Current

kA

34.8

Rated Line Charging Breaking Current

A

31.5

Rated Cable Charging Breaking Current

A

140

Number of Breaking Operations for Rated Short - circuit Breaking Current

times

20

Mechanical Life

times

10000

Mechanism/Operation Mode

/

Spring Operating Mechanism/Three - phase Mechanical Interlock

 

Documentation Resource Library
Restricted
Dead Tank Circuit Breakers Catalog
Catalogue
English
Consulting
Consulting
Restricted
138kV Station Switchgear Technical Specification with IEEE&ANSI
Technical Data Sheet
English
Consulting
Consulting
Restricted
138kV Station Switchgear Technical Specification with IEC
Technical Data Sheet
Chinese
Consulting
Consulting
FAQ
Q: What are the requirements for monitoring the gas decomposition products of the SF6 tank circuit breaker?
A:

During the normal operation and interruption processes of a circuit breaker, SF₆ gas can decompose, producing various decomposition products such as SF₄, S₂F₂, SOF₂, HF, and SO₂. These decomposition products are often corrosive, toxic, or irritating, and therefore require monitoring.If the concentration of these decomposition products exceeds certain limits, it may indicate abnormal discharges or other faults within the arc quenching chamber. Timely maintenance and handling are necessary to prevent further damage to the equipment and to safeguard personnel health.

Q: What are the leakage rate requirements for the arc quenching chamber of a tank-type circuit breaker?
A:

The leakage rate of SF₆ gas must be controlled at an extremely low level, typically not exceeding 1% per year. SF₆ gas is a potent greenhouse gas, with a greenhouse effect 23,900 times that of carbon dioxide. If a leak occurs, it can not only cause environmental pollution but also lead to a decrease in the gas pressure within the arc quenching chamber, affecting the performance and reliability of the circuit breaker.

To monitor the leakage of SF₆ gas, gas leakage detection devices are typically installed on tank-type circuit breakers. These devices help to promptly identify any leaks so that appropriate measures can be taken to address the issue.

Q: What are the structural characteristics of the tank circuit breaker?
A:

Integral Tank Structure:

  • Integral Tank Structure: The breaker's arc quenching chamber, insulating medium, and related components are sealed within a metal tank filled with an insulating gas (such as sulfur hexafluoride) or insulating oil. This forms a relatively independent and sealed space, effectively preventing external environmental factors from affecting the internal components. This design enhances the insulation performance and reliability of the equipment, making it suitable for various harsh outdoor environments.

Arc Quenching Chamber Layout:

  • Arc Quenching Chamber Layout: The arc quenching chamber is typically installed inside the tank. Its structure is designed to be compact, enabling efficient arc quenching within a limited space. Depending on different arc quenching principles and technologies, the specific construction of the arc quenching chamber may vary, but generally includes key components such as contacts, nozzles, and insulating materials. These components work together to ensure that the arc is quickly and effectively extinguished when the breaker interrupts the current.

Operating Mechanism:

  • Operating Mechanism: Common operating mechanisms include spring-operated mechanisms and hydraulic-operated mechanisms.

  • Spring-Operated Mechanism: This type of mechanism is simple in structure, highly reliable, and easy to maintain. It drives the opening and closing operations of the breaker through the energy storage and release of springs.

  • Hydraulic-Operated Mechanism: This mechanism offers advantages such as high output power and smooth operation, making it suitable for high-voltage and high-current class breakers.

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m²m² Total staff: 700+ Highest Annual Export(usD): 150000000
Workplace: 108000m²m²
Total staff: 700+
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

Related Solutions

Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.