110 - 500kV Fulmina Protectiva in Casingu Composito

  • 110 - 500kV Composite-Housed Line Surge Arresters

Attributa principalia

Marca ROCKWILL
Numerus Modeli 110 - 500kV Fulmina Protectiva in Casingu Composito
Votum nominatum 220kV
Frequenta nominata 50/60Hz
Series YH10CX

Descriptiones productorum a fornitori

Descriptio

Descriptio

Arrestoria lineae composito-vestita de 110 - 500kV sunt dispositiva protectiva specialia pro lineis transmissionis altae tensionis operantibus in ambitu 110kV ad 500kV. Inclusa in durabiles vestimenta composita (typice caoutchouc silicium), haec integra technologiam varistorum oxidis metallici (MOV) praestantem. Installata directe in lineis transmissionis, haec arrestoria servit ut defensio critica contra super-tensiones causatas ab fulguribus, transitiis commutationis et aliis perturbationibus electricis. Per rapidam diversionem currentium surgerentium ad terram et clausuram tensionum ad limines tutores, praeventur damnum componentium lineae, minuitur interrupcio potenciae, et securitas stabilitasque operationis reti transmissionis 110 - 500kV assecuratur.

Characteristica

Compatibilitas Tensionis LataAdaptata ut amplectat ambitum 110kV ad 500kV, haec arrestoria ingeniose constructa sunt ut congruant specificis requisitionibus tensionis lineae transmissionis altae tensionis. Haec versatilitas permittit ut praebent protectionem constantem et fiduciam per varios segmentos rete potenciae in hoc spectro tensionis.

Vestimentum Compositum DurabileVestimentum compositum (caoutchouc silicium) exhibet excellentiam performance. Praebet fortiter resistenciam factoribus ambientalibus sicut radiationi UV, extremis temperaturis, humiditati et pollutioni, securans stabilitatem longi temporis etiam in conditionibus externis duris. Plerumque levis natura simplificat installationem et minuit onus structurarum lineae transmissionis.

MOVs PraestantesEquipata cum varistoribus oxidis metallici qualitatis altae, haec arrestoria eximias characteristica nonlineares praebent. In eventibus super-tensionis, MOVs celeriter conducunt magnas currentes surgerentes, efficaciter limitantes spikes tensionis. In operatione normali, mantinent statum altae resistentiae, minimizantes currentem fuga et perditam energiam.

Design Lineae SpecificumDesignatum specificum pro integratione cum lineis transmissionis, haec habent structuram compactam et fluentem quae congruat configurationibus lineae sine difficultate. Hoc design securat impactum minimum in performance lineae dum praebet optimam protectionem, aptandum ut ad lineas overhead et quasdam subterraneas.

Superioritas in Gestionem SurgeCapax sustinendi altas currentes impulsus generatas ab severis fulguribus et surge commutationis. Haec robusta capacitas gestionis surge securat ut etiam sub extrema perturbatione electrica, arrestoria effectiviter mitigent impactum, tutantes insulatores lineae, conductores et alios componentes criticos.

Requisitia Minima MaintenanceVestimentum compositum est resistens ad senectutem et corrosionem, reducens necessitatem maintenance frequentis. MOVs designatae sunt pro fide longi temporis, cum stabilitate performance per periodos extenditos, minimizantes downtime et costus operationales associatos cum upkeep.

Compliance cum StandardibusAdhaeret standardibus industriae internationalibus sicut IEC 60099 - 4 et ANSI/IEEE C62.11, securans compatibilitatem cum systemibus transmissionis globalibus. Adhaerentia his standardibus garantit ut arrestoria satisfaciant strictis criteriis securitatis et performance, praebens fiduciam in effectivitatem operationis earum.

Fiducia Reti Potentiata:Per praeventionem tripping lineae et damni equipmenti causati ab super-tensionibus, haec arrestoria contribuunt significanter ad fiduciam totalem rete potenciae. Adiuvant in maintinendo continuae transmissionis potenciae, minuentes frequentiam et durationem interruptionum, quod est cruciale pro satisfactione demandarum usuarii industrialis, commercialis et residentialis.

Model 

Arrester

System

Arrester Continuous Operation

DC 1mA

Switching Impulse

Nominal Impulse

Steep - Front Impulse

2ms Square Wave

Nominal

Rated Voltage

Nominal Voltage

Operating Voltage

Reference Voltage

Voltage Residual (Switching Impulse)

Voltage Residual (Nominal Impulse)

Current Residual Voltage

Current - Withstand Capacity

Creepage Distance

kV

kV

kV

kV

kV

kV

kV

A

mm

(RMS Value)

(RMS Value)

(RMS Value)

Not Less Than

Not Greater Than

Not Greater Than

Not Greater Than

20 Times






(Peak Value

(Peak Value

(Peak Value

(Peak Value


YH10CX1-102/296

102

110

81.6

148


296


600

5438

YH10CX1-204/592

204

220

159

296


592


600

10600

YH20CX1-396/1050

396

500

297

561


1050


1200

23310

YH10CX1-204/592K

204

220

159

296


592


600

5400

YH10CX1-288/755

220

330

216

408


755


600

16100

Cognosce tui fornitori
Venditio Online
Ratio praestabilitae tradendae
Tempus responsionis
100.0%
≤4h
Brevis Descriptio Societatis
Locus Operis: 108000m²m² Numerus omnium laborantium: 700+ Summa Annua Exportatio (USD): 150000000
Locus Operis: 108000m²m²
Numerus omnium laborantium: 700+
Summa Annua Exportatio (USD): 150000000
Servitia
Genus Negotii: Design/Fabricatio/Venditio
Categorias Principales: apparatus electrum altum voltus/transformator
Gubernatio vitae
Servitia gestionis curae integralis pro quaestu, usu, conservatione et post-venditionem apparatus electricorum, securitatem operationis, continuationem imperii et usum electricitatis sine cura garantia.
Fornitori instrumentorum praeteritus est certificationem qualificationis platformae et iudicium technicum, ut ex fonte conformitas, professionalitas et fiducia servantur.

Producta Connexa

Cognitio Connexa

  • Accidentia Transformatoris Principalis et Questiones Operationis Gas Luminis
    1. Registri accidentis (XIX Martii, MMXIX)Hora XVI:XIIX die XIX Martii, MMXIX, monitorium background reportavit actionem gas levis transformatoris principis numeri III. Conformiter Codex Operationis Transformatorum Electricitatis (DL/T572-2010), personale operationis et maintenance (O&M) inspectavit statum in situ transformatoris principis numeri III.Confirmatio in situ: Panel non-electricus protectionis WBH transformatoris principis numeri III reportavit actionem gas levis phase B corpus tr
    02/05/2026
  • Culpae et Tractatio Terrae Unipolaris in Lineis Distributionis 10kV
    Characteristica et Instrumenta Detegendi Defectus Terrae Monofasiales1. Characteristica Defectuum Terrae MonofasialiumSigna Centralia Admonitionis:Campanula admonitionis sonat, et lucerna indicativa inscripta „Defectus Terrae in Sectione Omnibus [X] kV [Y]“ accenditur. In systematibus ubi punctum neutrum per bobinam Petersen (bobinam suppressionis arcus) ad terram connectitur, lucerna indicativa „Bobina Petersen Operatur“ etiam accenditur.Indicationes Voltmetri Monitoris Isolationis:Tensio phase
    01/30/2026
  • Modus operationis terre iunctae puncti neutralis pro transformatoribus retis electricitatis 110kV~220kV
    Dispositio modi operis terrae puncti neutralis pro transformatoribus rete electricitatis 110kV~220kV debet exigentias tolerationis insulationis puncti neutralis transformatorum complere, et simul conari ut impedimentum sequentiae nullae stationum transformationis fere immutatum maneat, dum certatur ne impedimentum sequentiae nullae compositum in quocumque puncto raptus circuiti systematis ultra ter impedimentum sequentiae positivae compositum excedat.Pro transformatoribus 220kV et 110kV in novis
    01/29/2026
  • Cur Quare Substationes Lapidem Gravem Calculos et Rupem Fractam Utuntur
    Cur Quare Substationes Utuntur Lapidibus, Gravibus, Piscinis et Saxis Tritis?In stationibus transformationis, instrumenta ut transformatores electricitatis et distributionis, lineae transmissionis, transformatores tensionis, transformatores currentis et commutatores disiunctionis omnia terram exigunt. Praeter terram, nunc profundius explorabimus cur gravia et saxa trita in stationibus transformationis saepe utuntur. Quamquam videantur ordinaria, isti lapides partem criticam iuxtaque functionalem
    01/29/2026
  • Cur autem nucleus transformatoris tantum in uno puncto terram tangere debet Nonne terra multipuncta fidelius est
    Cur ergo nucleus transformatoris terram tangere debet?In operatione, nucleus transformatoris, simul cum structuris, partibus et componentibus metallicis quae fixant nucleum et spiras, in forti campo electrico situs est. Sub influentia huius campi electrici, potentialem relativum altum ad terram comparatum acquirunt. Si nucleus non terra tangitur, differentia potentialis inter nucleum et structuras claudicantes et vas terratum existet, quae possit ad intermitterentiam dismissionem ducere.Praetere
    01/29/2026
  • Intellegere Terram Neutralis Transformatoris
    I. Quid est Punctum Neutrum?In transformatoribus et generatoribus, punctum neutrum est locus specificus in spira ubi absoluta tensio inter hunc locum et singula terminalia externa aequalis est. In diagrammate infra, punctumOrepraesentat punctum neutrum.II. Cur Punctum Neutrum Terrendum Est?Modus connexionis electricae inter punctum neutrum et terram in systemate AC triphasico diciturmodus terrendi puncti neutri. Hic modus directe afficit:Securitatem, fidem et oeconomiciam retelectrici;Selectione
    01/29/2026

Solutiones Relatae

  • Design Solution of 24kV Siccum Aera Insulatum Ring Main Unit
    Combinatio Solidi Insulationis Adiuvantis + Insulationis Aereae Siccae repraesentat directionem pro RMU 24kV. Per requirementa insulationis cum compactitate equilibrata et adiuvante solidum insulationis, testes insulationis sine magnificatione significativa dimensionum inter phasos et inter phasos et terram transigi possunt. Inclusio columnae pole solidificat insulationem pro interruptore vacuo et conductoribus eius coniunctis.Maintinendo spatium phasorum exiens 24kV ad 110mm, intensitas electri
    08/16/2025
  • Optimizatio Design Schematum pro Unitate Circulorum Principalium Aere Insulata 12kV ad Minuendam Probabilitatem Disruptionis Emissionis
    Cum celeri progressus industriae electricitatis, conceptus ecologicus de carbonis minore, energiae servanda, et conservatione ambientis profundissime integratus est in designum et fabricam productorum electricorum pro distributione et generatione electricitatis. Unitas Distributiva Circuli (RMU) est dispositivum electricum clavem in retibus distributionis. Securitas, conservatio ambientis, fides operativa, efficacia energetica, et oeconomia sunt tendentiae inevitabiles in eius progressu. RMUs tr
    08/16/2025
  • Analyse communium problematum in unitatibus principali circuitu isolatis gas 10kV (RMUs)
    Introductio:​​RMUs insulati gaseis 10kV sunt amplissime usitati propter multas suas utilitates, sicut quod sint perfecte clausi, habeant excellentem insulativam qualitatem, non requirant maintenance, sint compacti, et praebent installationem flexibilem et commodam. In hoc stadio, paulatim facti sunt nodus criticus in rete distributionis urbano anulari et iocabuntur partem significativam in systemate distributionis electricitatis. Difficultates in RMUs insulatis gaseis possunt graviter impingere
    08/16/2025
Non invenisti adhuc opportunos fornitoris ut te inveniant Citationem Nunc Accipe
Non invenisti adhuc opportunos fornitoris ut te inveniant
Citationem Nunc Accipe
Inquiry
+86
Click to upload file
Descarica
Obtine Applicatio Commerciale IEE-Business
Utiliza app IEE-Business ad inveniendum apparatus obtinendumque solutiones coniungendum cum peritis et participandum in collaboratione industriale ubique et semper propter totam supportionem tuorum projectorum electricitatis et negotiorum